Section 4 User Interface Guide
ATLAS 550 System Manual
186
© 2004 ADTRAN, Inc.
61200305L2-1B
M
ODULES
(BONDING) > C
ONFIGURATION
> TXINIT T
IMER
(
SEC
)
Write security: 3; Read security: 5
Specifies the length of time the originating endpoint attempts to detect the BONDING negotiation pattern
from the answering endpoint before deciding the BONDING call has failed.
M
ODULES
(BONDING) > C
ONFIGURATION
> TXFA T
IMER
(
SEC
)
Write security: 3; Read security: 5
Specifies the length of time both endpoints attempt to detect the BONDING frame pattern when a call is
connected before deciding the BONDING call has failed. When interoperating with other manufacturers'
BONDING equipment, it may be necessary to change this time so that it matches
TXADD01
.
M
ODULES
(BONDING) > C
ONFIGURATION
> TXADD01 T
IMER
(
SEC
)
Write security: 3; Read security: 5
Specifies the length of time both endpoints wait for additional calls to be connected at the end of
negotiation before deciding that the BONDING call has failed. The factory default setting is sufficient for
most calls to connect, although when dialing overseas it may be necessary to lengthen this timer to allow
for slower call routing.
M
ODULES
(BONDING) > C
ONFIGURATION
> TXDEQ T
IMER
(
SEC
)
Write security: 3; Read security: 5
Specifies the length of time both endpoints attempt to equalize the network delay between the bearer
channels before deciding the BONDING call has failed.
M
ODULES
(BONDING) > C
ONFIGURATION
> TANULL T
IMER
(
SEC
)
Write security: 3; Read security: 5
Specifies the length of time the answering endpoint attempts to detect the BONDING negotiation pattern
from the originating endpoint before deciding the BONDING call has failed. It may be necessary to
shorten this timer if the DTE equipment using the BONDING module also has timer constraints for
completing non-BONDING parameter negotiation.
M
ODULES
(BONDING) > C
ONFIGURATION
> TCID T
IMER
(
SEC
)
Write security: 3; Read security: 5
Specifies the length of time both endpoints attempt to negotiate an agreeable value for bearer channels and
channel capacities before deciding the BONDING call has failed.
Содержание ATLAS 550
Страница 16: ...Table of Contents ATLAS 550 System Manual 16 2004 ADTRAN Inc 61200305L2 1B ...
Страница 24: ...Section 1 System Description ATLAS 550 System Manual 24 2004 ADTRAN Inc 61200305L2 1B ...
Страница 62: ...Section 3 Network Turnup Procedure ATLAS 550 System Manual 62 2004 ADTRAN Inc 61200305L2 1B ...
Страница 308: ...Section 4 User Interface Guide ATLAS 550 System Manual 308 2004 ADTRAN Inc 61200305L2 1B ...
Страница 310: ...Section 5 Detail Level Procedures ATLAS 550 System Manual 310 2004 ADTRAN Inc 61200305L2 1B ...
Страница 320: ...Section 5 DLP 4 ATLAS 550 System Manual 320 2004 ADTRAN Inc 61200305L2 1B ...
Страница 326: ...Section 5 DLP 6 ATLAS 550 System Manual 326 2004 ADTRAN Inc 61200305L2 1B ...
Страница 330: ...Section 5 DLP 7 ATLAS 550 System Manual 330 2004 ADTRAN Inc 61200305L2 1B ...
Страница 348: ...Section 5 DLP 14 ATLAS 550 System Manual 348 2004 ADTRAN Inc 61200305L2 1B ...
Страница 351: ...61200305L2 1B 2004 ADTRAN Inc 351 CONFIGURATION GUIDES CFG 1 Dial Backup for Dedicated T1 Circuits 353 ...
Страница 352: ...Section 6 Configuration Guides ATLAS 550 System Manual 352 2004 ADTRAN Inc 61200305L2 1B ...
Страница 364: ...Section 6 CFG 1 ATLAS 550 System Manual 364 2004 ADTRAN Inc 61200305L2 1B ...
Страница 378: ...Section 7 System Event Logging ATLAS 550 System Manual 378 2004 ADTRAN Inc 61200305L2 1B ...
Страница 388: ...Section 8 ADTRAN Utilities ATLAS 550 System Manual 388 2004 ADTRAN Inc 61200305L2 1B ...
Страница 412: ...Section 9 MIBs ATLAS 550 System Manual 412 2004 ADTRAN Inc 61200305L2 1B ...