Section 3 Network Turnup Procedure
ATLAS 550 System Manual
56
© 2004 ADTRAN, Inc.
61200305L2-1B
6.
SUPPLYING POWER TO THE UNIT
AC-Powered Systems
The AC-powered ATLAS 550 comes equipped with a detachable 6-foot power cord with a 3-prong plug
for connecting to a grounded power receptacle. As shipped, the ATLAS 550 is set to factory default
conditions. To power-up the unit, ensure that the unit is properly connected to an appropriate power source
and turn on the unit using the on/off switch on the back panel.
DC-Powered Systems
The DC-powered ATLAS 550 comes equipped with a DC power supply to furnish the voltages necessary
for proper backplane operation. As shipped, the ATLAS 550 is set to factory default conditions. After
installing the unit and any option modules, the ATLAS 550 is ready for power-up.
7.
INSTALLING NETWORK AND OPTION MODULES
Figure 2 shows the option slot numbering designation as viewed from the back of the ATLAS 550.
Figure 2. ATLAS 550 Slot Designation (Back Panel)
•
Power to the ATLAS 550 AC system must be from a grounded 90-130/190-240 VAC,
50/60 Hz source.
•
The power receptacle uses double-pole, neutral fusing.
•
Maximum recommended ambient operating temperature is 45
o
C.
•
Power to the ATLAS 550 DC system must be from a reliably grounded -48 VDC or
+24 VDC source which is electrically isolated from the AC source.
•
Install this unit in accordance with Article 400 and 364.8 of the NEC NFPA 70.
•
The branch circuit overcurrent protection shall be a fuse or circuit breaker rated
minimum 60 VDC, maximum 10A.
•
A readily accessible disconnect device that is suitably approved and rated shall be
incorporated in the field wiring.
•
Maximum recommended ambient operating temperature is 45ºC.
O
I
ALL EMPTY SLOTS MUST BE
COVERED WITH BLANK PANELS
500 Series
500 Series
500 Series
CAUTION: FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE ONLY
WITH SAME TYPE AND RATING OF FUSE.
ETHERNET
ADMIN
RELAY
ALARM
MON
COM
NO
NC
500 Series
NETWORK 2
NETWORK 1
500 Series
500 Series
FUSE RATING: 2A/250V SLO-BLO
90-240VAC, 2A 50/60Hz
1
2
3
4
1
3
2
4
Ntwk 1
Ntwk 2
Содержание ATLAS 550
Страница 16: ...Table of Contents ATLAS 550 System Manual 16 2004 ADTRAN Inc 61200305L2 1B ...
Страница 24: ...Section 1 System Description ATLAS 550 System Manual 24 2004 ADTRAN Inc 61200305L2 1B ...
Страница 62: ...Section 3 Network Turnup Procedure ATLAS 550 System Manual 62 2004 ADTRAN Inc 61200305L2 1B ...
Страница 308: ...Section 4 User Interface Guide ATLAS 550 System Manual 308 2004 ADTRAN Inc 61200305L2 1B ...
Страница 310: ...Section 5 Detail Level Procedures ATLAS 550 System Manual 310 2004 ADTRAN Inc 61200305L2 1B ...
Страница 320: ...Section 5 DLP 4 ATLAS 550 System Manual 320 2004 ADTRAN Inc 61200305L2 1B ...
Страница 326: ...Section 5 DLP 6 ATLAS 550 System Manual 326 2004 ADTRAN Inc 61200305L2 1B ...
Страница 330: ...Section 5 DLP 7 ATLAS 550 System Manual 330 2004 ADTRAN Inc 61200305L2 1B ...
Страница 348: ...Section 5 DLP 14 ATLAS 550 System Manual 348 2004 ADTRAN Inc 61200305L2 1B ...
Страница 351: ...61200305L2 1B 2004 ADTRAN Inc 351 CONFIGURATION GUIDES CFG 1 Dial Backup for Dedicated T1 Circuits 353 ...
Страница 352: ...Section 6 Configuration Guides ATLAS 550 System Manual 352 2004 ADTRAN Inc 61200305L2 1B ...
Страница 364: ...Section 6 CFG 1 ATLAS 550 System Manual 364 2004 ADTRAN Inc 61200305L2 1B ...
Страница 378: ...Section 7 System Event Logging ATLAS 550 System Manual 378 2004 ADTRAN Inc 61200305L2 1B ...
Страница 388: ...Section 8 ADTRAN Utilities ATLAS 550 System Manual 388 2004 ADTRAN Inc 61200305L2 1B ...
Страница 412: ...Section 9 MIBs ATLAS 550 System Manual 412 2004 ADTRAN Inc 61200305L2 1B ...