ATLAS 550 System Manual
Section 4 User Interface Guide
61200305L2-1B
© 2004 ADTRAN, Inc.
301
D
IAL
P
LAN
(C
KT
B
ACKUP
) > U
SER
T
ERM
> I
FCE
C
ONFIG
> F
ORCE
M
ODE
Write security: 3; Read security: 5
This forces the backup state of this endpoint. This is a configuration setting, so it will retain its value until
it is changed. To temporarily force an endpoint into backup, or to force a restore, try the Manual activator.
D
IAL
P
LAN
(C
KT
B
ACKUP
) > U
SER
T
ERM
> I
FCE
C
ONFIG
> B
ACKUP
C
RITERIA
Write security: 3; Read security: 5
Criteria for automatic backup. Note that this setting affects the available options for
R
ESTORE
C
RITERIA
.
D
IAL
P
LAN
(C
KT
B
ACKUP
) > U
SER
T
ERM
> I
FCE
C
ONFIG
> R
ESTORE
C
RITERIA
Write security: 3; Read security: 5
This only applies to originating endpoints. These are criteria for automatically coming out of backup. Note
that
N
ETWORK
S
UCCESS
is only available when a backup criterion is not
N
ET
/D
ATA
F
AIL
.
D
IAL
P
LAN
(C
KT
B
ACKUP
) > U
SER
T
ERM
> I
FCE
C
ONFIG
> S
TARTUP
D
ELAY
Write security: 3; Read security: 5
The amount of time to wait after creating or changing the endpoint before allowing backup.
D
IAL
P
LAN
(C
KT
B
ACKUP
) > U
SER
T
ERM
> I
FCE
C
ONFIG
> B
ACKUP
D
ELAY
Write security: 3; Read security: 5
The amount of time to delay after detecting an alarm before going into backup. This only applies to
originating endpoints. If the circuit comes out of alarm before this time has expired, the endpoint will not
go into backup.
N
ET
/D
ATA
F
AIL
DBU is initiated when either the network fails (possible causes include Red,
Yellow, Blue, or LOS alarms) or when the Nx56/64 module detects a loss of
data transitions on the V.35 interface. If Net/Data Fail is selected, the V.35 Nx
INBAND option must be ON. The remote TSU INBAND option must also be
enabled.
When
B
ACKUP
C
RITERIA
is configured for
N
ET
/D
ATA
F
AIL
, the
R
ESTORE
C
RITERIA
must be
M
ANUAL
O
NLY
.
N
ET
F
AIL
DBU is initiated when there is a network failure. Possible causes include
LOS, RED, Yellow, or Blue alarms.
M
ANUAL
The ATLAS will never initiate DBU until it is manually set to do so.
N
ET
S
UCCESS
When network is out of alarm
M
ANUAL
O
NLY
Only by the Manual activator
Содержание ATLAS 550
Страница 16: ...Table of Contents ATLAS 550 System Manual 16 2004 ADTRAN Inc 61200305L2 1B ...
Страница 24: ...Section 1 System Description ATLAS 550 System Manual 24 2004 ADTRAN Inc 61200305L2 1B ...
Страница 62: ...Section 3 Network Turnup Procedure ATLAS 550 System Manual 62 2004 ADTRAN Inc 61200305L2 1B ...
Страница 308: ...Section 4 User Interface Guide ATLAS 550 System Manual 308 2004 ADTRAN Inc 61200305L2 1B ...
Страница 310: ...Section 5 Detail Level Procedures ATLAS 550 System Manual 310 2004 ADTRAN Inc 61200305L2 1B ...
Страница 320: ...Section 5 DLP 4 ATLAS 550 System Manual 320 2004 ADTRAN Inc 61200305L2 1B ...
Страница 326: ...Section 5 DLP 6 ATLAS 550 System Manual 326 2004 ADTRAN Inc 61200305L2 1B ...
Страница 330: ...Section 5 DLP 7 ATLAS 550 System Manual 330 2004 ADTRAN Inc 61200305L2 1B ...
Страница 348: ...Section 5 DLP 14 ATLAS 550 System Manual 348 2004 ADTRAN Inc 61200305L2 1B ...
Страница 351: ...61200305L2 1B 2004 ADTRAN Inc 351 CONFIGURATION GUIDES CFG 1 Dial Backup for Dedicated T1 Circuits 353 ...
Страница 352: ...Section 6 Configuration Guides ATLAS 550 System Manual 352 2004 ADTRAN Inc 61200305L2 1B ...
Страница 364: ...Section 6 CFG 1 ATLAS 550 System Manual 364 2004 ADTRAN Inc 61200305L2 1B ...
Страница 378: ...Section 7 System Event Logging ATLAS 550 System Manual 378 2004 ADTRAN Inc 61200305L2 1B ...
Страница 388: ...Section 8 ADTRAN Utilities ATLAS 550 System Manual 388 2004 ADTRAN Inc 61200305L2 1B ...
Страница 412: ...Section 9 MIBs ATLAS 550 System Manual 412 2004 ADTRAN Inc 61200305L2 1B ...