DLP-12 Connecting the ATLAS 550 to an External Modem

Introduction

The ATLAS 550 can be accessed and managed via an external modem, allowing the same capabilities to 
the user as if connected to the local 

ADMIN 

(

or

 CRAFT

)

 

port. 

Prerequisite Procedures

The ATLAS 550 should be mounted in its permanent location before connecting it to an external modem.

Tools and Materials Required

Female RJ-45 to Male DB-25 Connector (shipped with unit)

Modem

Modem Cable

To prevent electrical shock, do not install equipment in a wet location or during a 
lightning storm.

Electronic equipment can be damaged by static electrical discharge. Before handling it, 
put on an antistatic discharge wrist strap to prevent damage to electronic components. 
Place equipment in antistatic packing material when transporting or storing. When 
working on equipment, always place it on an approved antistatic mat that is electrically 
grounded.

Содержание ATLAS 550

Страница 1: ...5L2 1B August 2004 ATLAS 550 System Manual 1200305L2 ATLAS 550 Chassis AC Power Domestic Version 1200306L2 ATLAS 550 Chassis AC Power International Version 1200550L2 ATLAS 550 Chassis DC Power Domestic Version ...

Страница 2: ...equential damages or for commercial losses even if ADTRAN has been advised thereof as a result of issue of this publication About this Manual This manual provides a complete description of the ATLAS 550 System and system software The purpose of this manual is to provide the technician system administrator and manager with general and specific information related to the planning installation operat...

Страница 3: ... under document 61200305L1 1F New version created to include updated form factor and hardware information B August 2004 Revised to include more detailed mounting information and update compliance requirements Notes provide additional useful information Cautions signify information that could prevent service interruption Warnings provide information that could prevent damage to the equipment or end...

Страница 4: ...kitchen sink or laundry tub in a wet basement or near a swimming pool 2 Avoid using a telephone other than a cordless type during an electrical storm There is a remote risk of shock from lightning 3 Do not use the telephone to report a gas leak in the vicinity of the leak 4 Use only the power cord power supply and or batteries indicated in the manual 5 Do not dispose of batteries in a fire They ma...

Страница 5: ...s complaint with Part 68 and requirements adopted by ACTA 7 The following information may be required when applying to your local telephone company for leased line facilities 8 The REN is used to determine the quantity of devices which may be connected to the telephone line and still have all of those devices ring when the number is called Excessive RENs on the telephone line may result in the dev...

Страница 6: ...ent This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio frequencies Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded cables must be us...

Страница 7: ...mum number of terminals that can be connected to a telephone interface The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices should not exceed five 5 Canadian Emissions Requirements This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in t...

Страница 8: ...for eventual conversion into voiceband analog signal and transmitted on the network The affidavit shall affirm that either no encoded analog content or billing information is being transmitted or that the output of the device meets Part 68 encoded analog content or billing protection specifications End user customer will be responsible to file an affidavit with the local exchange carrier when conn...

Страница 9: ...Part 68 of the FCC Rules and Regulations The digital CPE does not transmit digital signals containing encoded analog content or billing information which is intended to be decoded within the telecommunications network The encoded analog content and billing protection is factory set and is not under the control of the customer I attest that the operator s maintainer s of the digital CPE responsible...

Страница 10: ...monstrate compliance with the information as provided in the preceding paragraph if so requested _________________________________Signature _________________________________Title _________________________________ Date Transcribed and sworn to before me This ________ day of _______________ _______ _________________________________ Notary Public My commission expires ________________________________...

Страница 11: ...tion under Support Customer Service Product Support Information and Training A return material authorization RMA is required prior to returning equipment to ADTRAN For service RMA requests training or more information use the following contact information Repair and Return If you determine that a repair is needed please contact our Customer and Product Service CaPS department to have an RMA number...

Страница 12: ...for support If additional support is needed the ADTRAN Support web site provides a variety of support services such as a searchable knowledge base updated firmware releases latest product documentation service request ticket generation and trouble shooting tools All of this and more is available at When needed further post sales assistance is available by calling our Technical Support Center Pleas...

Страница 13: ...clude overviews on product features and functions while covering applications of ADTRAN s product lines ADTRAN provides a variety of training options including customized training and courses taught at our facilities or at your site For more information about training please contact your Territory Manager or the Enterprise Training Coordinator Training Phone 800 615 1176 ext 7500 Training Fax 256 ...

Страница 14: ...Customer Service Product Support Information and Training ATLAS 550 System Manual 14 2004 ADTRAN Inc 61200305L2 1B ...

Страница 15: ...rd Security Levels 321 DLP 6 Updating the Firmware Using TFTP 323 DLP 7 Updating the Firmware Using XMODEM 327 DLP 8 Saving the Current Configuration Using TFTP 331 DLP 9 Loading a Configuration Using TFTP 333 DLP 10 Saving and Transferring a Current Configuration Using XMODEM 335 DLP 11 Loading a Configuration Using XMODEM 337 DLP 12 Connecting the ATLAS 550 to an External Modem 339 DLP 13 Using ...

Страница 16: ...Table of Contents ATLAS 550 System Manual 16 2004 ADTRAN Inc 61200305L2 1B ...

Страница 17: ... 19 Dual Nx 56 64 Option Module P N 1200311L1 19 Dual USSI Option Module P N 1200754L1 19 Dual Quad T1 PRI Option Module P N 1200314L1 L2 and 1200755L1 L2 19 Quad Basic Rate ISDN U Interface Option Module P N1200315L1 19 Quad Basic Rate ISDN S T Interface Option Module P N 1200764L1 19 Octal Quad FXS Option Module P N 1200309L1 1200328L1 19 Octal Quad FXO Option Module P N 1200310L1 1200329L1 20 O...

Страница 18: ...t accommodate hot swappable option modules for a variety of applications A 10 100BaseT Ethernet connection for IP routing and network management is standard with the ATLAS 550 base unit With the ATLAS 550 you can consolidate voice data and video applications into a single platform while optimizing wide area bandwidth and reducing equipment costs The ATLAS 550 architecture and the four expansion sl...

Страница 19: ...r private frame relay network and passes frame relay data with RFC 1490 encapsulation to one or more serial ports V 35 Passes Systems Network Architecture SNA Bisync and other legacy protocols between a public or private frame relay network and an external DTE running Frame Relay to the ATLAS 550 Performs voice compression decompression G 723 1 and interfaces to either a Private Branch Exchange PB...

Страница 20: ... Module P N 1200326L1 Legacy Data Option Module P N 1200342L1 NxT1 HSSI V 35 Option Module P N 1200346L2 Each option module contains a variety of performance and alarm status information Although default values reflect the most common configurations several features of each module are user configurable All option modules contain an extensive self test as well as tests designed for the technology t...

Страница 21: ... synchronous DTE ports that can operate from 56 kbps to 2 048 Mbps in steps of 56 or 64 kbps Either port can deliver timing for the system Using the appropriate adapter cables the Dual USSI Option Module can provide the following interface types EIA 530 EIA 530A RS 449 RS 232 and CCITT X 21 Dual Quad T1 PRI Option Module P N 1200314L1 L2 and 1200755L1 L2 The Dual Quad T1 PRI Module provides two or...

Страница 22: ...ces into a single logical channel on the HSSI interface or the V 35 interface using an optional adapter cable The NxT1 HSSI V 35 Option Module supports point to point T1 applications only Any of the four built in T1 ports of the NxT1 HSSI V 35 Option Module can provide timing for the ATLAS 550 system Octal Ethernet Switch Option Module P N 1200766L1 The Octal Ethernet Switch Option Module provides...

Страница 23: ...le P N 1200326L1 The Nx 56 64 BONDing Resource Option Module supports multiple independent BONDing sessions with each session capable of using from two to thirty two channels of 56K or 64K data The Nx 56 64 BONDing Resource Module combines with other ATLAS 550 components to provide a flexible disaster recovery system ...

Страница 24: ...Section 1 System Description ATLAS 550 System Manual 24 2004 ADTRAN Inc 61200305L2 1B ...

Страница 25: ... 1200327L1 USOC RJ 49C 34 Option Module Interfaces 34 Octal Quad FXS Option Module P N 1200309L1 1200328L1 8 Pin Modular Jack 34 Octal Quad FXO Option Module P N 1200310L1 1200329L1 8 Pin Modular Jack 35 Dual Nx 56 64 Option Module P N 1200311L1 V 35 Winchester 35 Dual USSI Option Module P N 1200754L1 DB 78 36 Octal E M Option Module P N 1200313L1 8 Pin Modular Jack 40 Dual Quad T1 PRI Option Modu...

Страница 26: ...lar Jack Pinout 35 Table 14 V 35 Winchester Pinout 35 Table 15 DB 78 Connector Pinout 36 Table 16 EIA 530 Connector Pinout System P N 4200754L2 37 Table 17 EIA 530A Connector Pinout System P N 4200754L2 37 Table 18 RS 449 V 36 Connector Pinout P N 4200754L1 38 Table 19 RS 232 Connector Pinout P N 4200754L4 39 Table 20 CCITT X 21 V 11 Connector Pinout P N 4200754L3 39 Table 21 E M 8 Pin Modular Jac...

Страница 27: ...tains the Alarm Cut off switch ACO the CRAFT port and the status LEDs for the system controller the network modules and the option modules Figure 1 identifies the ACO switch the CRAFT port and the LEDs Figure 1 ATLAS 550 Front Panel Layout ACO Switch Pressing the ACO switch deactivates clears the Alarm Relay located on the back panel of the ATLAS 550 after an alarm condition has occurred If an ala...

Страница 28: ...cates whether a user is logged into the unit Network Module LEDs Display the status of the two network interfaces see Table 3 on page 29 All LEDs are off if no network module is installed OK Indicates that the network interface is operating correctly Test Indicates that the network interface is in test mode Error Blinks to indicate the occurrence of error events Alarm Indicates an alarm condition ...

Страница 29: ...own no Ethernet connection Remote Yellow a user is logged into the system via the ADMIN CRAFT port or via the ETHERNET port Off there are no users logged into the system Network Modules Status OK Green solid the network interface is operating normally with error free operation If the interface experiences alarms the OK LED remains off Test Yellow solid the interface is operating in a test mode Thi...

Страница 30: ... solid a port on the installed module is currently in alarm Red fast blink one module has no response has been removed or is not supported Red slow blink one module is not ready Off no module occupies the slot Online Green solid one or both modules in the case of a Resource Module have an active connection Green fast blink one module has invalid flash memory or is downloading firmware Green slow b...

Страница 31: ...ERED WITH BLANK PANELS 500 Series 500 Series 500 Series CAUTION FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE ETHERNET ADMIN RELAY ALARM MON COM NO NC 500 Series NETWORK 2 NETWORK 1 500 Series 500 Series FUSE RATING 2A 250V SLO BLO 90 240VAC 2A 50 60Hz 1 2 3 4 AC Power Connection Option Module Slots Alarm Relay Connection Network Module Slots 10 100Ba...

Страница 32: ...wnloads using XMODEM Ethernet Connection USOC RJ 48C The ETHERNET port RJ 48C provides a 10 100BaseT ETHERNET LAN connection which is used for IP routing TFTP SNMP and Telnet connections Table 5 shows the pinout Table 4 ADMIN Port Pinout Pin Name Description 1 SG Signal Ground 2 RTS Request to Send output follows CTS 3 TD Transmit Data input 4 DTR Data Terminal Ready output 12 V 5 RD Receive Data ...

Страница 33: ...e front panel of the ATLAS 550 Table 7 shows the pinout for the Alarm Relay connector 5 NETWORK INTERFACE MODULES The ATLAS 550 provides two Network Interface Slots that allow different types of interfaces to be used Available Network Interface Modules include the following T1 PRI Network Interface Module P N 1200307L1 L2 USOC RJ 48C See page 34 E1 PRA Network Interface Module P N 1200308L1 15 pin...

Страница 34: ... nonintrusive monitoring of the incoming T1 When connected to this jack configure the test equipment for bridged termination E1 PRA Network Interface Module P N 1200308L1 15 pin female D connector The E1 PRA Network Interface Module provides a single E1 PRA port see Table 9 on page 35 that pro vide the following functions AMI or HDB3 coding Manual line build out NFAS FAS TS16 MF and CRC 4 framing ...

Страница 35: ...e provides a single 6 pin modular jack RJ 11C see Table 10 for the pinout The Modem Management Network Module provides the following functions V 34 V 32bis V 32 V 22 V 23 and V 21 data modulation schemes Connection rates from 2400 to 33 6K baud V 42 LAPM MNP 2 4 and MNP 10 error correction methods V 42bis and MNP 5 data compression algorithms Table 9 E1 PRA Network Interface 15 pin Female D connec...

Страница 36: ... P N 1200313L1 8 Pin Modular Jack See page 42 Dual Quad T1 PRI Option Module P N 1200314L1 L2 and 1200755L1 L2 USOC RJ 48C See page 43 Quad BRI U Interface Option Module P N 1200315L1 USOC RJ 48C See page 43 Quad BRI ISDN S T Interface Option Module P N 1200764L1 USOC RJ 45 See page 43 NxT1 HSSI Option Module P N 1200346L1 50 Pin SCSI II See page 44 NxT1 HSSI V 35 Option Module P N 1200346L2 See p...

Страница 37: ...rom the analog phone interface 5 TIP Tip to and from the analog phone interface Table 14 V 35 Winchester Pinout Pin CCITT Description A 101 Protective ground PG B 102 Signal ground SG C 105 Request to send RTS from DTE D 106 Clear to send CTS to DTE E 107 Data set ready DSR to DTE F 109 Received line signal detector DCD to DTE H Data terminal ready DTR from DTE J Ring indicator RI R 104 Received d...

Страница 38: ... 4 RXC B 2 50 MOD0 5 TXD A 2 51 EXT TXC A 1 6 TXD B 2 52 DTR B 1 7 TXC A 2 53 DTR A 1 8 TXC B 2 54 DCD B 1 9 EXT TXC A 2 55 DCD A 1 10 EXT TXC B 2 56 DSR B RI 1 11 17 UNUSED 57 DSR A 1 18 GND 58 CTS B 1 19 GND 59 CTS A 1 20 CHASIS GND 60 CHASIS GND 21 CTS A 2 61 GND 22 CST B 2 62 68 UNUSED 23 DSR A 2 69 MOD1 24 DSR B RI 2 70 EXT TXC B 1 25 DCD A 2 71 TXC B 1 26 DCD B 2 72 TXC A 1 27 DTR A 2 73 TXD...

Страница 39: ... B 24 Ext Transmit Clock A 12 Transmit Clock B 25 Test Mode 13 Clear to Send B Asterisk indicates that this pin is ignored by Dual USSI Module Table 17 EIA 530A Connector Pinout System P N 4200754L2 Pin Signal Description Pin Signal Description 1 Shield Ground 14 Transmit Data B 2 Transmit Data A 15 Transmit Clock A 3 Received Data A 16 Received Data B 4 Request to Send A 17 Receive Clock A 5 Clea...

Страница 40: ... B 6 Received Data A 25 Request to Send B 7 Request to Send A 26 Receive Clock B 8 Receive Clock A 27 Clear to Send B 9 Clear to Send A 28 Terminal in Service 10 Local Loopback 29 DCE Ready B 11 DCE Ready A 30 DTE Ready B 12 DTE Ready A 31 Carrier Detect B 13 Carrier Detect A 32 Select Standby 14 Remote Loopback 33 Signal Quality 15 Ring Indicator 34 New Signal 16 Select Frequency 35 Ext Transmit ...

Страница 41: ...nal Detector 21 Signal Quality Detector 9 Voltage 22 Ring Indicator 10 Voltage 23 Data Signal Rate Selector 11 Unused 24 DTE Transmit Clock 12 Sec Received LIne Signal Indicator 25 Unused 13 Sec Clear to Send Asterisk indicates that this pin is ignored by Dual USSI Module Table 20 CCITT X 21 V 11 Connector Pinout P N 4200754L3 Pin Signal Description Pin Signal Description 1 Shield Ground 9 Transmi...

Страница 42: ... shows the E M signaling types Table 21 E M 8 Pin Modular Jack Pinout PIN Name Description 1 Ring VF input 4W mode 600 Ω nominal Tip Ring 2W mode 600 Ω 2 16 µF nominal 2 Tip 3 E Customer Originate 4 SG Signal Ground 5 SB Signal Battery 6 M Network Originate 7 Tip 1 VF output 4W mode 600 Ω nominal 8 Ring 1 Table 22 Trunk Circuit Connections for Various E M Signaling Types Signaling Type Trunk Circu...

Страница 43: ...ad BRI ISDN S T Interface Option Module uses a single RJ 45 jack for connection to a standard BRI S T interface circuit The Quad BRI ISDN S T Interface Option Module is only available for use in NT mode User Term applications Table 25 shows the network pinout connection Table 23 T1 PRI RJ 48C Pinout Pin Name Description 1 RXDATA RING R Receive data from the network 2 RXDATA TIP T1 Receive data fro...

Страница 44: ... for the V 35 and RJ 48C T1 connectors respectively Table 26 HSSI SCSI II 50 Pin Connection Pinout Pin side Pin side Description Pin side Pin side Description 1 26 SG Signal Ground 10 35 LA Loopback Circuit A 2 27 RT Receive Timing 11 36 SD Send Data 3 28 CA DCE Available 12 37 LB Loopback Circuit B 4 29 RD Receive Data 13 38 SG Signal Ground 5 30 LC Loopback Circuit C 14 18 39 43 Ancillary to DCE...

Страница 45: ...erved 19 44 HSSI SG Signal Ground 20 45 O V 35 ST Send Timing 21 46 O V 35 Receive Timing 22 47 O V 35 RD Receive Data 23 O V 35 CTS Clear to Send 48 I V 35 Ground Present 24 49 O TM Test Mode 25 50 SG Signal Ground Table 28 T1 Network Connection Pinout Pin Name Description 1 RXDATA RING R1 Receive data from the network 2 RXDATA TIP T1 Receive data from the network 4 TXDATA RING R Send data toward...

Страница 46: ...ion A 101 Protective ground PG 7 B 102 Signal ground SG 4 C 105 Request to send RTS from DTE 5 D 106 Clear to send CTS to DTE 6 E 107 Data set ready DSR to DTE 8 F 109 Received line signal detector DCD to DTE 20 H 108 2 Data terminal ready DTR from DTE 22 J 125 Ring indicator RI to DTE 3 R 104 Received data RD A to DTE 3 T 104 Received data RD B to DTE 17 V 115 RX clock RC A to DTE 17 X 115 RX clo...

Страница 47: ...C RJ 48C The Octal Ethernet Switch Option Module provides eight RJ 48C interfaces that can operate as 10BaseT or 100BaseTX Table 30 gives the pinout for the Ethernet connection Table 30 Ethernet RJ 48C Pinout Pin Name Description 1 TX1 Transmit Positive 2 TX2 Transmit Negative 3 RX1 Receive Positive 4 5 Unused 6 RX2 Receive Negative 7 8 Unused ...

Страница 48: ...p connections 160 Dedicated map connections in each of the five maps one active map at a time Switching Applications ISDN signaling types National ISDN Lucent 5E AT T 4ESS PRI Only Northern DMS 100 Nortel Custom EuroISDN T1 signaling types Loop Start Ground Start E M Wink E M Immediate Feature Group D DSP Features DTMF tones support FSK Caller ID support Progress tone generation 32 available DSP c...

Страница 49: ...CN Discard eligible DE Quality of service QOS Prioritization on a per PVC basis Testing ADTRAN proprietary PVC loopback Round trip delay measurement SNMP support RFC 1315 PPP Connection support 100 connections Authentication support PAP CHAP EAP Keepalive support On Off Interface support Numbered interfaces Unnumbered interfaces IP Routing Route discovery RIP V1 RIP V2 ICMP ARP IARP UDP Relay SNMP...

Страница 50: ...32 compression channels PCM coding µ Law Fax support 9600 bps Modem Support ADPCM 32 Module only The rates shown at the right are maximum rates Under certain conditions these rates may not be realized G 711 Transparent ADPCM 32 V 34 28 8 bps V 32 14 4 bps FAX 14 4 bps FAX 14 4 bps ADPCM 16 V 21 300 bps V 22 1200 bps FAX NOT RECOMMENDED DTMF generation and detection TIA 464A Table 31 ATLAS 550 Syst...

Страница 51: ...le P N 1200341L1 56 BRI DBU Network Module P N 1200327L1 56 Dual Quad T1 PRI Option Module P N 1200314L1 L2 and 1200755L1 L2 56 Dual Nx 56 64 Option Module P N 1200311L1 56 Dual USSI Option Module System P N 4200754Lx 57 Quad Basic Rate ISDN U Interface Option Module P N 1200315L1 57 Quad Basic Rate ISDN S T Interface Option Module P N 1200764L1 57 Octal Quad FXS Option Module P N 1200309L1 120032...

Страница 52: ...TRAN Customer Service see the contact information in the front of this manual Contents of ADTRAN Shipments Your ADTRAN shipment includes the following items Shipping contents for the modules begin on page 57 The ATLAS 550 unit The ATLAS 550 Product CD AC power cord ADTRAN P N 3127031 with AC systems 19 rackmount brackets and screws RJ 45 to DB 25 adapter ADTRAN P N 3196ADPT006 To prevent electrica...

Страница 53: ...round in a manner that will retain the ground connection when the product is unplugged from the receptacle The connection to ground of the supplementary equipment grounding conductor shall be in compliance with the rules for terminating bonding jumpers at Part K or Article 250 of the National Electrical Code ANSI NFPA 70 Termination of the supplementary equipment grounding conductor is permitted t...

Страница 54: ...g bolts through the unit s brackets and into the equipment rack using a 2 Phillips head screwdriver 4 Proceed to the steps given in Supplying Power to the Unit on page 56 Wallmount Installation Step Action 1 Attach the wallmount brackets to the sides of the chassis Wallmount brackets are the same as 19 inch rackmount brackets and are included in the shipment To avoid damaging the unit use only the...

Страница 55: ...ge 56 Wallmount Installation Continued Step Action Step 4 Wall mount the ATLAS 550 chassis using four 6 to 10 1 1 2 or greater in length wood screws Step 1 Attach both wall mount brackets supplied in shipment to chassis using four 6 32 5 16 in length screws supplied in shipment Step 2 Remove screws using a Phillips head screwdriver and disconnect all four rubber feet on the bottom of the chassis S...

Страница 56: ...TLAS 550 Figure 2 ATLAS 550 Slot Designation Back Panel Power to the ATLAS 550 AC system must be from a grounded 90 130 190 240 VAC 50 60 Hz source The power receptacle uses double pole neutral fusing Maximum recommended ambient operating temperature is 45 oC Power to the ATLAS 550 DC system must be from a reliably grounded 48 VDC or 24 VDC source which is electrically isolated from the AC source ...

Страница 57: ... shipment of the T1 PRI Network Interface Module includes the following items T1 PRI Network Interface Module T1 PRI Network Interface Module Quick Start Guide One T1 cable RJ 48C to RJ 48C ADTRAN P N 3125M008 One T1 crossover cable RJ 48C to RJ 48C ADTRAN P N 3125M010 E1 PRA Network Interface Module P N 1200308L1 Shipping Contents The ADTRAN shipment of the E1 PRA Network Interface Module include...

Страница 58: ...k Start Guide Two Four T1 cables RJ 48C to RJ 48C ADTRAN P N 3125M008 Two T1 crossover cables RJ 48C to RJ 48C ADTRAN P N 3125M010 Dual Nx 56 64 Option Module P N 1200311L1 Shipping Contents The ADTRAN shipment of the Dual Nx 56 64 Option Module includes the following items Dual Nx 56 64 Option Module Dual Nx 56 64 Option Module Quick Start Guide Customer Provides DTE cables Dual USSI Option Modul...

Страница 59: ... Basic Rate ISDN S T Interface Option Module Quad Basic Rate ISDN S T Interface Option Module Quick Start Guide Four RJ 45 to RJ 11 cables ADTRAN P N 3125M007 Octal Quad FXS Option Module P N 1200309L1 1200328L1 Shipping Contents The ADTRAN shipment of the Octal Quad FXS Option Module includes the following items Octal Quad FXS Option Module Octal Quad FXS Option Module Quick Start Guide Octal Qua...

Страница 60: ...AN shipment of the NxT1 HSSI Option Module includes the following items NxT1 HSSI Option Module NxT1 HSSI Option Module Quick Start Guide Four T1 cables RJ 45 to RJ 45 ADTRAN P N 3125M008 Optional accessories include the following SCSI II 50 pin to V 35 cable ADTRAN P N 1200763L1 Octal Ethernet Switch Option Module P N 1200766L1 Shipping Contents The ADTRAN shipment of the Ethernet Switch Option M...

Страница 61: ... 16 24 Channel Voice Compression Resource Modules Quick Start Guide 32 Channel ADPCM Resource Module P N 1200752L1 Shipping Contents The ADTRAN shipment of the 32 Channel ADPCM Resource Module includes the following items 32 Channel ADPCM Resource Module 32 Channel ADPCM Resource Module Quick Start Guide Nx 56 64 BONDing Resource Module P N 1200326L1 Shipping Contents The ADTRAN shipment of the Nx...

Страница 62: ...Section 3 Network Turnup Procedure ATLAS 550 System Manual 62 2004 ADTRAN Inc 61200305L2 1B ...

Страница 63: ...work Interface Module 115 Modules Menu Dual Quad T1 PRI Option Modules 120 Modules Menu Dual Nx56 64 Option Module 126 Modules Menu Dual USSI Option Module 133 Modules Menu Quad Basic Rate ISDN U Interface Option Module 140 Modules Menu Quad Basic Rate ISDN S T Interface Option Module 143 Modules Menu Quad Octal FXS Option Module 146 Modules Menu Quad Octal FXO Option Module 150 Modules Menu Octal...

Страница 64: ... 301 FIGURES Figure 1 Top Level Terminal Menu Window 63 Figure 2 Alternate Menu View 64 Figure 3 System Info Menu 69 Figure 4 System Status Menu 71 Figure 5 System Config Menu 78 Figure 6 System Utility Menu 90 Figure 7 View Selftest Log 95 Figure 8 Modules Menu 99 Figure 9 T1 PRI Loopback Test Diagram 106 Figure 10 E1 PRA Network Loopback Test Diagram 112 Figure 11 T1 PRI Loopback Test Diagram 12...

Страница 65: ...s Terminal Menu Window After logging in all menu items and data fields are displayed in the terminal menu window see Figure 1 through which you have complete control of the ATLAS 550 Figure 1 Top Level Terminal Menu Window Menu Path The first line of the terminal menu window the menu path shows the session s current position path in the menu structure For example Figure 1 shows the top level menu ...

Страница 66: ...in moving between and within the two window panes Right Window Pane Notation The right window pane shows the contents of the currently selected menu These contents include both submenu items and data fields Some submenus contain additional submenus and some data fields contain additional data fields The following chart explains the notation used to identify these additional items To do this Press ...

Страница 67: ...rent time Navigating using the Keyboard Keys You can use various keystrokes to move through the terminal menu to manage a terminal menu session and to configure the system Press CTRL Z to activate a pop up screen listing the navigation keystrokes Moving through the Menus To do this Press this key Return to the home screen H Jump between two menu items Press J while the cursor is located on a menu ...

Страница 68: ...opy selected items to the clipboard The amount of information you can copy depends on the cursor location when you press C If the cursor is over an editable field only that item is copied If the cursor is over the index number of a list then all of the items in the row of the list are copied For example if the cursor is over the SLOT field in the MODULES screen all of the information associated wi...

Страница 69: ...ions and parameters Use the chart below to help select the appropriate terminal menu To do this Go to this menu Review and monitor general system information for the ATLAS 550 SYSTEM INFO Review and monitor system status for the ATLAS 550 SYSTEM STATUS Set up the operational configuration for the ATLAS 550 SYSTEM CONFIG Update settings transfer files perform system diagnostics and reboot the ATLAS...

Страница 70: ...TIONS The remainder of this section describes ATLAS 550 menu and submenu options Table 1 Password Security Levels Allowable Actions Password Levels 5 4 3 2 1 0 read menus only D D D D D D use only test commands D D D D D use other commands D D D D set interface configuration D D D flash download D D authentication methods D D set password D To help you follow the terminal menu hierarchy the follow...

Страница 71: ...ters in this field including spaces and special characters such as an underbar SYSTEM INFO SYSTEM LOCATION Write security 3 Read security 5 Provides a user configurable text string for the location of the ATLAS 550 This field is to help you keep track of the physical location of the unit You can enter up to 40 alphanumeric characters in this field including spaces and special characters such as an...

Страница 72: ...e this field to read WARM REBOOT SYSTEM INFO CURRENT TIME DATE 24HR Write security 3 Read security 5 Displays the current date and time including seconds To edit this field place the cursor on the field and press Enter Then enter the time in a 24 hour format such as 23 00 00 for 11 00 pm and the date in mm dd yyyy format for example 10 30 1998 Press Enter when you are finished to accept the change...

Страница 73: ...s the last 349 warning or failure messages sent including the day date and priority of the message The most recent messages display at the top of the list The following read only fields are available to review SYSTEM STATUS EVENT LOG TIME Read security 5 Displays the date mm dd and the time hh mm ss that the event occurred SYSTEM STATUS EVENT LOG CAT Read security 5 Displays the severity of the ev...

Страница 74: ...e security 3 Read security 3 Clears the event log When you select this command the following prompt displays Select Y to clear the log or N to exit the command SYSTEM STATUS CLEAR SYSTEM LED Write security 3 Read security 3 Changes the color of the SYSTEM LED on the front panel from yellow indicating a previous error to green OK The SYSTEM LED turns red if the ATLAS 550 detects a major system fail...

Страница 75: ...etwork is 10 or 100BaseT SYSTEM STATUS CHAIN PORT Write security 2 Read security 5 Displays the status of the RJ 45 female ADMIN or CRAFT port SYSTEM STATUS CHAIN PORT SIGNAL LEADS Read security 5 Displays the state of the ADMIN or CRAFT port signals RTS CTS DTR and DCD SYSTEM STATUS CHAIN PORT TX BYTES Read security 5 Displays the number of bytes transmitted from the ADMIN or CRAFT port SYSTEM ST...

Страница 76: ...ill be placed in the EVENT LOG see Section 7 System Event Logging for more details The following status symbols are used SYSTEM STATUS SYSTEM TIMING SOURCE Read security 5 Indicates which timing source primary or backup is currently being used by ATLAS 550 and whether the system is locked onto this source If the display does not indicate locked the ATLAS 550 does not have a valid source of timing ...

Страница 77: ...eset SYSTEM STATUS RESOURCE USAGE DATA TABLES MIN Read security 5 Shows the fewest number of resources available since the last reset SYSTEM STATUS RESOURCE USAGE DATA TABLES 0 ZERO AVAIL Read security 5 Provides a count of the number of times the quantity of available resources reached 0 SYSTEM STATUS RESOURCE USAGE DATA TABLES HR DATA Read security 5 Displays the AVERAGE MINIMUM and 0 AVAILABLE ...

Страница 78: ...BS trunks configured as NETWORK TERM NETPRI Primary Rate ISDN circuits configured as NETWORK TERM USERRBS T1 RBS trunks configured as USER TERM and USERPRI Primary Rate ISDN circuits configured as USER TERM SYSTEM STATUS TRUNK USAGE DATA TABLES CURRENT Read security 5 Shows the number of resources available not in use and the total number of resources If a resource is taken offline it is not inclu...

Страница 79: ...AGE CONFIG Write security 5 Read security 5 Configures the statistics displayed under data tables SYSTEM STATUS TRUNK USAGE CONFIG DISPLAY FORMAT Write security 5 Read security 5 Sets the display format for all TRUNK USAGE statistics to either RAW DATA or PERCENTAGES SYSTEM STATUS TRUNK USAGE CONFIG RESET MODE Write security 3 Read security 5 Sets the reset mode for the TRUNK USAGE statistics to o...

Страница 80: ...MING SOURCE Write security 1 Read security 5 Selects the secondary timing source You can select either INTERNAL or any port available on the system that is capable of providing timing Please refer to the specific module information to determine if a port can provide timing for the system The ATLAS 550 uses the backup timing source if the primary timing source goes into alarm The BACKUP TIMING SOUR...

Страница 81: ...l numbers each in the range of 0 to 255 separated by periods This value is set to 10 0 0 1 by default The IP address is used for the 10 100BaseT ETHERNET interface Obtain the correct IP address from your LAN administrator SYSTEM CONFIG ETHERNET PORT DEFAULT GATEWAY Write security 2 Read security 5 Defines or changes the default gateway Enter the default gateway address by entering a decimal number...

Страница 82: ... BOUND RENEWING REBINDING INIT REBOOT REBOOTING and NON INIT SYSTEM CONFIG ETHERNET PORT LEASE EXPIRES Read security 5 Displays the date and time the current IP address lease will expire and a new one will be necessary SYSTEM CONFIG ETHERNET PORT RELEASE Write security 2 Read security 5 Forces the ATLAS 550 to release the currently assigned IP address SYSTEM CONFIG ETHERNET PORT RENEW Write securi...

Страница 83: ...tion for the ATLAS 550 SYSTEM CONFIG CHAIN PORT INITIALIZE MODEM Write security 4 Read security 5 Sends the modem initialization string to the modem When you select this command the following message displays PLEASE VERIFY A MODEM IS CONNECTED TO THE CHAIN PORT BEFORE CONTINUING CONFIRM Y N Ensure that a modem is connected before selecting Y SYSTEM CONFIG ADMIN PORT FLOW CONTROL Write security 2 R...

Страница 84: ...he GET or SET name defined on the network management station NMS PUBLIC is the default name SYSTEM CONFIG SNMP TRAP TRANSMISSION Write security 3 Read security 5 Enables and disables SNMP trap transmission SYSTEM CONFIG SNMP AUTHEN TRAP TRANSMISSION Write security 3 Read security 5 Enables and disables the authentication failure trap The authentication failure trap is sent when ENABLED each time a...

Страница 85: ...nterprise MIB and the DS1 Extension MIB These MIB listings are available on the documentation CD or the ADTRAN website at www adtran com for more MIB specific information Click Service Support Technical Support ATLAS Products ATLAS 550 MIBs If a statistic value exceeds its threshold value then the corresponding Alert Trap will be sent if the Alert Event is armed and Alert Traps are enabled These t...

Страница 86: ...rent 15 minute Line Errored Seconds LES parameter The default value is 65 for an approximate BER level of 10E 5 SYSTEM CONFIG SNMP DS1 CURRENT PERF THRESHOLDS CURRENT LCV THRSH Write security 3 Read security 5 The DS1 performance monitor Threshold Value for the Current 15 minute Line Code Violations LCV parameter The default value is 13 340 for an approximate BER level of 10E 5 SYSTEM CONFIG SNMP ...

Страница 87: ...is 691 framing errors for an approximate BER level of 10E 5 SYSTEM CONFIG SNMP DS1 TOTAL PERF THRESHOLDS TOTAL PCV THRSH ESF Write security 3 Read security 5 The DS1 performance monitor Threshold Value for the Total Path Code Violations PCV parameter when the Line Type is Extended Super Frame DS1 The default value is 132 960 CRC errors for an approximate BER level of 10E 5 SYSTEM CONFIG SNMP DS1 T...

Страница 88: ...ing through the ATLAS 550 to remote ADTRAN TSU 100 Series or ISU 512 units When enabled this feature allows the ATLAS 550 to forward any traps received from remote units to the network management station NMS listed in the TRAPS DESTINATION field The remote unit must be listed in the ASP ENDPOINT COMMUNITIES for the traps to be forwarded SYSTEM CONFIG EVENT LOGGING Write security 3 Read security 5 ...

Страница 89: ...M CONFIG ACCESS PASSWORDS Write security 0 Read security 0 Provides a way to edit passwords and to add new users and passwords All menu items are protected by passwords of varying security levels By assigning different passwords to different security levels the ATLAS 550 system administrator can control which users can change various menu items You can assign multiple passwords at the same access ...

Страница 90: ...ONDING call has failed When interoperating with other manufacturers BONDING equipment it may be necessary to change this time so that it matches TXADD01 SYSTEM CONFIG BONDING CONFIG TXADD01 TIMER Write security 3 Read security 5 Specifies the length of time both endpoints wait for additional calls to be connected at the end of negotiation before deciding that the BONDING call has failed The factor...

Страница 91: ...ER Write security 3 Read security 5 Specifies the amount of delay between placing calls for outgoing BONDING sessions The following call stagger values are available NO STAGGER 500 MS 1 SEC and 2 SEC SYSTEM CONFIG ALARM RELAY RESET Write security 3 Read security 5 Clears the Alarm Relay located on the back panel of the ATLAS 550 Activating the software Alarm Relay Reset functions the same as manua...

Страница 92: ... in ETHERNET port of the system controller and Trivial File Transfer Protocol TFTP For more details on updating firmware please refer to DLP 6 and DLP 7 SYSTEM UTILITY UPDATE FIRMWARE MODULE SLOT Write security 1 Read security 5 Displays the slot you selected for firmware updating When this option first appears NONE SELECTED displays When you move the cursor to this field and press Enter a dialog ...

Страница 93: ...and filename for the file SYSTEM UTILITY UPDATE FIRMWARE RESTART SCHEDULE Write security 1 Read security 5 Indicates when to restart the updated module to invoke the new software after selecting a module slot The two options include RESTART IMMEDIATELY AFTER UPDATE and RESTART AT SPECIFIED DATE AND TIME SYSTEM UTILITY UPDATE FIRMWARE RESTART SCHEDULE RESTART IMMEDIATELY AFTER UPDATE Write security...

Страница 94: ...TY UPDATE FIRMWARE BEGIN FIRMWARE UPDATE Write security 1 Read security 5 Begins updating the firmware for the selected modules To start this action enter Y to begin or enter N to cancel You can also cancel the operation after the update has begun For XMODEM updates cancel the process via the terminal emulation software consult your documentation for the information on how to do this For TFTP upda...

Страница 95: ...0BaseT ETHERNET port or select XMODEM to use the CRAFT or ADMIN interfaces and a program such as Windows HyperTerminal SYSTEM UTILITY CONFIG TRANSFER TFTP SERVER IP ADDRESS Write security 3 Read security 5 Specifies the IP address of the TFTP server Get this address information from your System Administrator SYSTEM UTILITY CONFIG TRANSFER TFTP SERVER FILENAME Write security 3 Read security 5 Defin...

Страница 96: ... security 5 Activates the self test To confirm self test activation press Y to cancel the self test press N SYSTEM UTILITY SYSTEM SELFTEST SELECTED TESTS Write security 3 Read security 5 Allows the user to select a system wide test or an individual card test Choose from ALL TESTS SLOT 0 SYS CTRL or any other installed option network resource module SYSTEM UTILITY SYSTEM SELFTEST CURRENT TEST STATU...

Страница 97: ...f the log entry SL ATLAS 550 slot number PT ATLAS 550 port number EVENT Event description RESULT Show PASS FAIL results Table 2 ATLAS 550 System Controller Self Test Log THIS EVENT LOGS THIS RESULT Flash Flash memory checksum verified BootRom Boot ROM checksum verified DSP RAM Memory associated with the Digital Signal Processor RTC RAM Memory associated with the real time clock NV Batt Tests the b...

Страница 98: ...G SIZE BYTES Write security 5 Read security 5 Specifies the size in bytes of the data portion of the ping request The default value is 64 bytes and the maximum size is 1024 bytes SYSTEM UTILITY PING TIMEOUT MS Write security 5 Read security 5 Specifies the time in milliseconds to wait for the ping reply before timing out The default timeout is 3 seconds 3000 and the maximum timeout value is 10 sec...

Страница 99: ...u either starts or stops sending pings SYSTEM UTILITY ATEL CLIENT Write security 5 Read security 5 Allows a user to remotely configure ADTRAN TSUs using ADLP over the inband management channel on a V 35 port This feature only allows for remote sessions through the ATLAS 550 to the TSUs not vice versa SYSTEM UTILITY ATEL CLIENT ATEL ADDRESS Write security 5 Read security 5 Defines the ADLP address ...

Страница 100: ...emote unit configured in the ADDRESS field SYSTEM UTILITY CLIENT STATUS Write security 5 Read security 5 Displays status from current Telnet client sessions SYSTEM UTILITY CLIENT STATUS USER NAME Displays the username from access passwords list that has an active Telnet client session SYSTEM UTILITY CLIENT STATUS SESSION ID Displays the remote unit s IP address followed by the IP port of an active...

Страница 101: ...s status information and menu options that allow you to configure and control the installed option modules as well as the network ports see Figure 8 Figure 8 Modules Menu This will delete all configuration settings ADTRAN recommends making a backup copy of the configuration before defaulting the system If you install a module in a slot then want to install a different type of module in the slot yo...

Страница 102: ... it displays in the TYPE field If this field is already configured with a module you can only set this field to EMPTY To change from one module type to another you must first set the field to EMPTY MODULES MENU Read security 5 Displays additional status and configuration menus for the ATLAS 550 controller or selected module To access the submenus for this item use the arrow keys to scroll to the M...

Страница 103: ...ontroller automatically detects the presence of the T1 PRI Network Interface Module when it is installed in the system listed as T1 PRI 1 To see the menus for the T1 PRI Network Interface Module via the terminal menu use the arrow keys to scroll to the MODULES menu and press Enter to access the module choices Refer to the T1 PRI Network Interface Module Quick Start Guide for a menu tree containing...

Страница 104: ...ES T1 PRI 1 ALARM STATUS PRT Read security 5 Indicates the port number MODULES T1 PRI 1 ALARM STATUS ALARMS Read security 5 Displays an alarm condition on the ATLAS 550 unit Press Enter to access this menu item MODULES T1 PRI 1 RX LEVEL RECEIVE LEVEL Indicates the strength of the signal in dB received on the port LOS Indicates a loss of signal detected on port interface RED Indicates inability to ...

Страница 105: ...ere robbed bit signaling RBS is not being transferred by the ATLAS 550 MODULES T1 PRI 1 PERFORMANCE CURRENT Write security 3 Read security 5 The performance fields either CURRENT 15 MINUTE total or 24 HOUR total provide status on key performance measures as specified in ANSI T1 403 and AT T TR54016 for the T1 PRI port Except for CLR these fields are all read only The monitored parameters include t...

Страница 106: ...econd ES is a second with one or more error events OR one or more Out Of Frame events OR one or more Controlled Slips BES Bursty Errored Second BES is a second with more than one but less than 320 error events SES Severely Errored Second SES is a second with 320 or more error events OR one or more Out Of Frame events SEFS Severely Errored Frame Second is a second that contains four consecutive err...

Страница 107: ... 5 Controls the sending of performance report messaging PRM data on the facility data link FDL The PRM data continues to be collected even if XMIT PRM is turned off possible only with ESF format Choose either ON or OFF MODULES T1 PRI 1 CONFIGURATION LBO Write security 2 Read security 5 Selects the Line Build Out LBO for the network interface When connecting an ATLAS 550 port to a DSX 1 interface t...

Страница 108: ...Choose ENABLE to activate the ADLP over the FDL for the DS1 interface MODULES T1 PRI 1 TEST Write security 5 Read security 5 These options initiate different types of tests and display test results MODULES T1 PRI 1 TEST PRT Read security 5 Displays the port number MODULES T1 PRI 1 TEST LOC LB Write security 4 Read security 5 Initiates a loopback on near end local port see Figure 9 The following op...

Страница 109: ...ity 3 Read security 3 Injects errors into transmitted test pattern Selection Framing Description AT T INBAND LINE ESF D4 Full 1 544 Mbps loopback of the signal received from the network metallic loopback ANSI FDL LINE ESF Full 1 544 Mbps loopback of the signal received from the network Initiated through loopback activation transmission over the facility data link FDL ANSI FDL PYLD ESF 1 536 Mbps l...

Страница 110: ...ork Interface Module Quick Start Guide for a menu tree containing a complete listing of menus MODULES E1 PRA 1 INFO Read security 5 Displays general information about the E1 PRA Network Interface Module MODULES E1 PRA 1 INFO PART NUMBER Read security 5 Displays the part number of the E1 PRA Network Interface Module MODULES E1 PRA 1 INFO SERIAL NUMBER Read security 5 Displays the module s serial nu...

Страница 111: ...oss of Signal No signal detected on port interface LOF Loss of Framing The receiver is unable to synchronize to the FAS framing pattern of the received signal LOMF Loss of Multi frame The receiver is unable to synchronize to the TS15 multi frame pattern of the received signal CRC4 Loss of CRC 4 Framing The receiver is unable to synchronize to the CRC 4 frame pattern of the received signal AIS Alar...

Страница 112: ...lays the port number CLR Clears performance information for the selected port ES Errored Second ES is a second with one or more error events OR one or more Out Of Frame events OR one or more Controlled Slips BES Bursty Errored Second BES is a second with more than one but less than 320 error events SES Severely Errored Second SES is a second with 320 or more error events OR one or more Out Of Fram...

Страница 113: ...MODULES E1 PRA 1 CONFIGURATION CRC 4 Write security 3 Read security 5 Transmits the CRC 4 checksum bits in the outgoing E1 data stream when enabled Also checks the received signal for errors MODULES E1 PRA 1 CONFIGURATION AUTO ALARM Write security 3 Read security 5 Transmits a remote alarm when framing is lost when Red Alarm Generation is on and transmits an AIS alarm when all ones are received wh...

Страница 114: ...der If not specifically used the bits should be set to 1 on paths crossing a border Enter the international bit value of 0 or 1 Refer to CCITT G 704 for more information MODULES E1 PRA 1 CONFIGURATION LINE BUILD OUT Write security 3 Read security 5 Sets the line build out for the E1 interface to either 75 Ω BALANCED or UNBALANCED or 120 Ω BALANCED or UNBALANCED MODULES E1 PRA 1 TEST Write security...

Страница 115: ...NT NETWORK MODULE The ATLAS 550 system controller automatically detects the presence of the Modem Management Network Module when it is installed in the system listed as MODMMGMT To see the menus for the Modem Management Network Module via the terminal menu use the arrow keys to scroll to the MODULES menu and press Enter to access the module choices Refer to the Modem Management Network Module Quic...

Страница 116: ...t to the network MODULES MODMMGMT STATUS RX BYTES Read security 5 Displays the number of bytes received by the analog port from the network MODULES MODMMGMT STATUS OVERRUN ERRS Read security 5 Displays the number of overrun errors received by the analog port MODULES MODMMGMT STATUS FRAMING ERRS Read security 5 Displays the number of framing errors received by the analog port MODULES MODMMGMT STATU...

Страница 117: ...pabilities for the internal modem MODULES MODMMGMT TEST DETECT DIAL TONE Write security 5 Read security 5 Causes the internal modem to go off hook to detect dial tone on the analog line MODULES MODMMGMT TEST DIAL TONE DETECTED Read security 5 Displays the results of the last DETECT DIAL TONE test MODULES MENU BRI DBU NETWORK INTERFACE MODULE The ATLAS 550 system controller automatically detects th...

Страница 118: ...LES DBU BONDING STATUS STATUS Read security 5 Displays the current status of the BONDING session The following states are available IDLE Indicates the number of Idle BONDING resources for a particular BONDING engine RESERVED BONDING resources reserved for a BONDING session that is in the process of coming up NEGOTIATING A single channel is connected and negotiating the BONDING call for a particula...

Страница 119: ...DULES DBU BONDING CONFIGURATION TXINIT TIMER Write security 3 Read security 5 Specifies the length of time the originating endpoint attempts to detect the BONDING negotiation pattern from the answering endpoint before deciding the BONDING call has failed MODULES DBU BONDING CONFIGURATION TXFA TIMER Write security 3 Read security 5 Specifies the length of time both endpoints attempt to detect the B...

Страница 120: ...l capacities before deciding the BONDING call has failed MODULES DBU BONDING CONFIGURATION CALL STAGGER Write security 3 Read security 5 Specifies the amount of delay between placing calls for outgoing BONDING sessions The following call stagger values are available NO STAGGER 500 MS 1 SEC and 2 SEC MODULES DBU BRI ALARM Read security 5 Displays the alarm status for the selected BRI DBU Network In...

Страница 121: ... All of the following configurable parameters apply to the BRI interface on the BRI DBU Network Interface Module MODULES DBU BRI CONFIGURATION PRT Read security 5 Displays the port number MODULES DBU BRI CONFIGURATION PORT NAME Write security 3 Read security 5 Accepts any alpha numeric name up to 16 characters long to uniquely identify the BRI interface on the BRI DBU Network Interface Module MODU...

Страница 122: ...arrow keys to scroll to the MODULES menu and press Enter to access the module choices Refer to the Dual Quad T1 PRI Option Modules Quick Start Guide for a menu tree containing a complete listing of menus MODULES T1 PRI 2 4 INFO Read security 5 Displays general information about the T1 PRI Network Interface Module as follows MODULES T1 PRI 2 4 INFO PART NUMBER Read security 5 Displays the part numb...

Страница 123: ...urity 5 The DS0 status indicates usage on a DS0 basis These options are read only LOS Indicates a loss of signal detected on port interface RED Indicates inability to frame data received on the port Alternately referred to as Out of Frame OOF YELLOW Receiving remote alarm RAI on port BLUE Receiving unframed all ones from the port Alarm Indicator Signal AIS DS0 ALARM Displays per DS0 alarm status t...

Страница 124: ...ameters include the following No Alarm DS0 D D Channel Alarm ISDN F Frame Alarm packet T TBOP Alarm packet P PPP Alarm packet PRT Displays the port number CLR Clears performance information for the selected port ES Errored Second ES is a second with one or more error events OR one or more Out Of Frame events OR one or more Controlled Slips BES Bursty Errored Second BES is a second with more than o...

Страница 125: ...MODULES T1 PRI 2 4 CONFIGURATION PORT NAME Write security 3 Read security 5 Accepts any alpha numeric name up to 16 characters long to uniquely identify each port on the ATLAS 550 MODULES T1 PRI 2 4 CONFIGURATION FRAME Write security 2 Read security 5 This field must be set to match the frame format of the circuit to which it is connected available from the network supplier Choose either D4 or ESF...

Страница 126: ...NSI T1 403 This is a line loopback Choose either ACCEPT or IGNORE MODULES T1 PRI 2 4 CONFIGURATION PULSE DENSITY Write security 3 Read security 5 Choose either ON or OFF When ON Pulse Density Enforcer causes the ATLAS 550 to monitor for ones 1s density violations and insert a one 1 when needed to maintain ones at 12 5 This data insertion will cause data errors MODULES T1 PRI 2 4 CONFIGURATION ADLP...

Страница 127: ...ic loopback ANSI FDL LINE ESF Full 1 544 Mbps loopback of the signal received from the network Initiated through loopback activation transmission over the facility data link FDL ANSI FDL PYLD ESF 1 536 Mbps loopback of the payload data received from the network maintaining bit sequence integrity for the information bits by synchronizing regenerating the timing Initiated through loopback activation...

Страница 128: ...f the Dual Nx 56 64 Option Module when it is installed in the system listed as V35NX 2 To see the menus for the Dual Nx 56 64 Option Module via the terminal menu use the arrow keys to scroll to the MODULES menu and press Enter to access the module choices Refer to the Dual Nx 56 64 Option Module Quick Start Guide for a menu tree containing a complete listing of menus MODULES V35NX 2 INFO Read secu...

Страница 129: ...35NX 2 DTE STATUS DTE STATUS Read security 5 The following signals are monitored these options are read only SLIP A rate mismatch exists between the DTE clock and the network side clock as set by DS0 assignment PLL The Nx port is not able to lock onto the clock provided by the network interface ZERO The DTE is sending an excessive number of consecutive zeroes to the network interface NO EXT CLK Th...

Страница 130: ...nel statistics MODULES V35NX 2 INBAND STATS PORT Read security 5 Operating port number There are 2 available interfaces on the Dual Nx56 64 Option Module MODULES V35NX 2 INBAND STATS RX FRAMES Read security 5 The number of frames received on the operating port since system startup MODULES V35NX 2 INBAND STATS TX FRAMES Read security 5 The number of frames transmitted from the operating port since ...

Страница 131: ...ers long to uniquely identify each port on the Dual Nx56 64 Option Module MODULES V35NX 2 CONFIGURATION CLK Write security 3 Read security 5 Controls the clock used by the ATLAS 550 to accept the transmit TX data from the DTE This is usually set to NORMAL If the interface cable is long causing a phase shift in the data the clock can be set to INVERTED This switches the phase of the clock which com...

Страница 132: ...RMAL DSR will generally be asserted when the interface is capable of passing data If set to FORCED ON DSR will always be asserted If set to REMOTE DTR the value of DSR will track the value of the remote unit s DTR signal This remote feature requires the Inband control channel to be ENABLED MODULES V35NX 2 CONFIGURATION DTR Write security 3 Read security 5 Determines whether the ATLAS 550 treats a ...

Страница 133: ...E Write security 3 Read security 5 Configures the dialing mode The following options are available MODULES V35NX 2 DIAL DIAL Write security 0 Read security 0 Signals the Nx port to dial clear the call MODULES V35NX 2 DIAL SRC ID Write security 3 Read security 5 Indicates the SOURCE ID of the number to be dialed Configure this field in the Nx INTERFACE CONFIGURATION section of the DIAL PLAN MODULES...

Страница 134: ...5 Controls the activation of the 511 test pattern generator and detector MODULES V35NX 2 TEST 511 RESULT Read security 5 Displays the results of the 511 test This option is read only Clear these results by pressing Enter when CLR is selected NO LOOPBACK No active loopback LOCAL LOOPBACK Activates both a local loopback back toward the DTE and a port loopback toward the network REMOTE LOOPBACK V 54 ...

Страница 135: ...the MODULES menu and press Enter to access the module choices Refer to the Dual USSI Option Module Quick Start Guide for a menu tree containing a complete listing of menus MODULES USSI 2 INFO Read security 5 Provides information about the module part number serial number and assembly revision MODULES USSI 2 INFO PART NUMBER Read security 5 Displays the part number of the module MODULES USSI 2 INFO...

Страница 136: ...ly operating A port s data rate is determined by the number of DS0s assigned to it and the rate per DS0 associated with the active maps SLIP A rate mismatch exists between the DTE clock and the network side clock as set by DS0 assignment PLL The USSI port is not able to lock onto the clock provided by the network interface ZERO The DTE is sending an excessive number of consecutive zeroes to the ne...

Страница 137: ...ad security 5 The number of frames received on the operating port since system startup MODULES USSI 2 INBAND STATS TX FRAMES Read security 5 The number of frames transmitted from the operating port since system startup MODULES USSI 2 INBAND STATS RX BYTES Read security 5 The number of bytes received on the operating port since system startup MODULES USSI 2 INBAND STATS TX BYTES Read security 5 The...

Страница 138: ...e transmit TX data from the DTE This is usually set to NORMAL If the interface cable is long causing a phase shift in the data the clock can be set to INVERTED This switches the phase of the clock which compensates for a long cable MODULES USSI 2 CONFIGURATION DATA Write security 3 Read security 5 Controls the inverting of the DTE data This inversion can be useful when operating with a high level ...

Страница 139: ...he ATLAS 550 treats a connection as permanent IGNORE or connects only when Data Terminal Ready DTR is active CONNECT ON DTR Select either IGNORE or CONNECT ON DTR MODULES USSI 2 CONFIGURATION 0 INH Write security 3 Read security 5 When the port detects an uninterrupted string of 0s being transmitted for more than one second setting this parameter to ON will cause the ATLAS 550 to send 1s toward th...

Страница 140: ... USSI port to dial clear the call MODULES USSI 2 DIAL SRC ID Write security 3 Read security 5 Indicates the SOURCE ID of the number to be dialed Configure this field in the USSI INTERFACE CONFIGURATION section of the DIAL PLAN MODULES USSI 2 DIAL NUMBER Write security 3 Read security 5 Indicates the number to be dialed Configure this field in the USSI INTERFACE CONFIGURATION section of the DIAL PL...

Страница 141: ...s selected MODULES USSI 2 TEST INJECT Write security 4 Read security 4 Injects errors into transmitted test pattern MODULES USSI 2 TEST CLR Write security 4 Read security 4 Clears error counters on test pattern results menu NO LOOPBACK No active loopback LOCAL LOOPBACK Activates both a local loopback back toward the DTE and a port loopback toward the network REMOTE LOOPBACK V 54 loopback code to b...

Страница 142: ...f the Quad BRI U Interface Option Module when it is installed in the system listed as U BRI 4 To see the menus for the Quad BRI U Interface Option Module via the terminal menu use the arrow keys to scroll to the MODULES menu and press Enter to access the module choices Refer to the Quad BRI U Interface Option Module Quick Start Guide for a menu tree containing a complete listing of menus AUTO The ...

Страница 143: ... 5 Displays the alarm status for each U interface on the installed module MODULES U BRI 4 ALARMS PRT Read security 5 Indicates the port number There are 4 available interfaces on the Quad BRI U Option Module MODULES U BRI 4 ALARMS ALARMS Read security 5 Displays the current alarm status of each BRI U interface MODULES U BRI 4 CHANNEL STATUS Read security 5 Displays the status of each of the BRI U ...

Страница 144: ...I U interfaces MODULES U BRI 4 CONFIGURATION PRT Read security 5 Displays the port number There are 4 available interfaces on the Quad BRI U Option Module MODULES U BRI 4 CONFIGURATION PORT NAME Write security 3 Read security 5 Accepts any alpha numeric name up to 16 characters long to uniquely identify each port on the installed module MODULES U BRI 4 TEST Write security 5 Read security 5 These o...

Страница 145: ...listing of menus MODULES ST BRI 4 INFO Write security 5 Read security 5 Provides information about the module part number serial number and assembly revision MODULES ST BRI 4 INFO PART NUMBER Read security 5 Displays the part number of the module MODULES ST BRI 4 INFO SERIAL NUMBER Read security 5 Displays the serial number of the module MODULES ST BRI 4 INFO ASSEMBLY REVISION Read security 5 Disp...

Страница 146: ...d BRI S T Option Module MODULES ST BRI 4 CHANNEL USAGE CHA Write security 5 Read security 5 Channel Displays the status of individual channels The following symbols may display MODULES ST BRI 4 CONFIGURATION Write security 5 Read security 5 Allows the user to personally identify each port with an appropriate name MODULES ST BRI 4 CONFIGURATION PRT Write security 5 Read security 5 Displays the port...

Страница 147: ...ntom power to TE equipment Set this parameter to ON only if the TE equipment connected to the S T interface requires line power MODULES ST BRI 4 TEST Write security 5 Read security 5 These options initiate different types of tests and display test results MODULES ST BRI 4 TEST PRT Write security 5 Read security 5 Identifies the port number There are 4 available interfaces on the Quad BRI S T Optio...

Страница 148: ...k Start Guide for a menu tree containing a complete listing of menus MODULES FXS 4 8 INFO Read security 5 Provides information about the module part number serial number and assembly revision MODULES FXS 4 8 INFO PART NUMBER Read security 5 Displays the part number of the module MODULES FXS 4 8 INFO SERIAL NUMBER Read security 5 Displays the serial number of the module MODULES FXS 4 8 INFO ASSEMBL...

Страница 149: ...urrent flowing REVERSE BATTERY The FXS port has reversed T R polarity RINGING The FXS port is detecting ringing condition on the interface TIP OPEN The FXS port tip conductor is high impedance This is an idle condition for GS trunks UNKNOWN No information about the FXS port is available INACTIVE The port is preconfigured but the FXS module is not present AVAILABLE The FXS port is present and avail...

Страница 150: ...TEST TX ABCD Write security 4 Read security 5 Forces the Transmit Robbed Bit Signaling Tx RBS to a specified value Values include OFF 0000 0101 1010 or 1111 MODULES FXS 4 8 TEST 1KHZ TONE Write security 3 Read security 5 Sends a 1kHz tone into the following locations based on test selection NEAR sends the tone out the FXS port while FAR sends the tone into the digital PCM stream of the ATLAS 550 c...

Страница 151: ...rs long to uniquely identify each port on the FXS Option Module MODULES FXS 4 8 CONFIG RX GAIN Write security 3 Read security 5 Adjusts the Gain and Attenuation of the relative signal received by the FXS The range includes 0 loudest 3 and 6 dB softest MODULES FXS 4 8 CONFIG TX GAIN Write security 3 Read security 5 Adjusts the Gain and Attenuation of a digital signal transmitted by the FXS into the...

Страница 152: ...enus for the Octal Quad FXO Option Module via the terminal menu use the arrow keys to scroll to the MODULES menu and press Enter to access the module choices Refer to the Quad Octal FXO Option Module Quick Start Guide for a menu tree containing a complete listing of menus MODULES FXO 4 8 INFO Read security 5 Provides information about the module part number serial number and assembly revision MODU...

Страница 153: ...F HOOK The FXO port has detected an off hook condition loop current flowing REVERSE BATTERY The FXO port has reversed T R polarity RINGING The FXO port is detecting ringing condition on the interface TIP OPEN The FXO port tip conductor is high impedance This is an idle condition for GS trunks UNKNOWN No information about the FXO port is available INACTIVE The port is preconfigured but the FXO modu...

Страница 154: ...FF LOOP OPEN LOOP CLOSED and RING GROUND The 2W tests will disrupt the active call on the selected FXO port Table 4 displays the state of the 2W conductors during each test MODULES FXO 4 8 TEST TX ABCD Write security 4 Read security 5 Forces the Transmit Robbed Bit Signaling Tx RBS to a specified value Values include OFF 0000 0101 1010 or 1111 MODULES FXO 4 8 TEST 1KHZ TONE Write security 3 Read s...

Страница 155: ...uniquely identify each port on the FXO Option Module MODULES FXO 4 8 CONFIG RX GAIN Write security 3 Read security 5 Adjusts the Gain and Attenuation of the relative signal received by the FXO port Digital to Analog The range includes 0 loudest 3 and 6 dB softest MODULES FXO 4 8 CONFIG TX GAIN Write security 3 Read security 5 Adjusts the Gain and Attenuation of a digital signal transmitted by the ...

Страница 156: ... via the terminal menu use the arrow keys to scroll to the MODULES menu and press Enter to access the module choices Refer to the Octal E M Option Module Quick Start Guide for a menu tree containing a complete listing of menus MODULES E M 8 INFO PART NUMBER Read security 5 Displays the part number of the module MODULES E M 8 INFO SERIAL NUMBER Read security 5 Displays the serial number of the modu...

Страница 157: ...bit pattern is formatted ESF RBS MODULES E M 8 TEST Write security 4 Read security 5 These options initiate different types of tests and display test results MODULES E M 8 TEST PORT Write security 5 Read security 5 Displays the operating port INACTIVE The port is pre configured but the E M module is not present DISABLED The E M module is present but the port is not mapped UNKNOWN Information about...

Страница 158: ...ne out the E M VF port while FAR sends the tone into the digital PCM stream of the ATLAS 550 controller These tests are useful for verifying a voice path MODULES E M 8 TEST LOOPBACK Write security 3 Read security 5 Activates loopback tests on a per port basis MODULES E M 8 CONFIG Write security 3 Read security 5 All of the following configurable parameters apply to the individual E M ports Table 5...

Страница 159: ...E M TYPE V mode MODULES E M 8 CONFIG VF IFCE Write security 3 Read security 5 Selects either 4 wire or 2 wire output at the VF interface The range includes 6 dB loudest to 12 dB softest MODULES E M 8 CONFIG RX GAIN Write security 3 Read security 5 Adjusts the level of the signal output at the VF interface The range includes 6 dB loudest to 12 dB softest MODULES E M 8 CONFIG TX GAIN Write security ...

Страница 160: ... of the module MODULES LEGACY 4 INFO ASSEMBLY REVISION Read security 5 Displays the assembly revision of the module MODULES LEGACY 4 INFO FIRMWARE REVISION Read security 5 Displays the current firmware revision of the selected module MODULES LEGACY 4 INFO PROCESSOR ID Read security 5 Displays the processor ID of the selected module MODULES LEGACY 4 SIGNAL STATUS Read security 5 Shows the status of...

Страница 161: ...ES LEGACY 4 PORT STATS FR OUT Read security 5 Frames Out Displays the total transmitted frames since the last reset MODULES LEGACY 4 PORT STATS ERR FR Read security 5 Errored Frames Displays the total errored received frames since the last reset MODULES LEGACY 4 PORT STATS OVER ERR Read security 5 Overrun Errors Displays a count of the receive FIFO first in first out buffer overrun frames Overrun ...

Страница 162: ...detects the presence of the NxT1 HSSI and NxT1 HSSI V 35 Option Modules when they are installed in the system NxT1 HSSI listed as NXT1 HSSI and NxT1 HSSI V 35 listed as NXHSSV35 All menus listed below as NXT1 HSSI apply to both the NxT1 HSSI and NxT1 HSSI V 35 Option Modules unless otherwise specified To see the menus for the NxT1 HSSI and NxT1 HSSI V 35 Option Modules via the terminal menu use th...

Страница 163: ...for the selected T1 interface There are four available T1 interfaces on the NxT1 HSSI and NxT1 HSSI V 35 Option Modules MODULES NXT1HSSI ALARM STATUS ALARMS Read security 5 Provides a listing of possible alarm conditions on the T1 interface An asterisk indicates the presence of an alarm condition and a hyphen indicates no active alarm The following alarms are monitored MODULES NXT1HSSI ALARM STATU...

Страница 164: ... port is connected to a Primary Rate ISDN circuit or a channelized T1 circuit PRT Displays the port number CLR Clears performance information for the selected port ES Errored Second ES is a second with one or more error events OR one or more Out Of Frame events OR one or more Controlled Slips BES Bursty Errored Second BES is a second with more than one but less than 320 error events SES Severely E...

Страница 165: ...t is connected this information is available from the network supplier Choose either AMI Alternate Mark Inversion or B8ZS Bipolar Eight Zero Substitution MODULES NXT1HSSI CONFIGURATION TX YEL Write security 3 Read security 5 Controls the transmission of yellow alarms Choose either ON or OFF MODULES NXT1HSSI CONFIGURATION LBO Write security 2 Read security 5 Selects the Line Build Out LBO for the n...

Страница 166: ...the port number for the T1s mapped to the HSSI interface Ports 1 through 4 are the T1 interfaces located on the NxT1 HSSI or NxT1 HSSI V 35 Option Modules Ports 5 through 8 are T1s mapped to the NxT1 HSSI or NxT1 HSSI V 35 Option Modules in the DEDICATED MAPS MODULES NXT1HSSI IMUX MENUS STATUS LINK Read security 5 Displays status information for the T1 data streams mapped to the HSSI interface The...

Страница 167: ...DULES NXT1HSSI IMUX MENUS CONFIG SCRAMBLE Enabling the SCRAMBLE option configures the NxT1 HSSI Module to prevent ones density violations when transmitting ADTRAN IMUX headers on a T1 circuit with AMI line coding MODULES NXT1HSSI HSSI MENUS Read security 5 Provides status configuration and testing parameters for the 50 pin SCSI II HSSI interface MODULES NXT1HSSI HSSI MENUS STATUS Read security 5 D...

Страница 168: ...e DCE independently of TA when the DCE is prepared to both send and receive data to and from the DTE This indicates that the DCE has obtained a valid data communications channel Data transmission should not commence until TA has also been asserted by the DTE LOCAL DTE LOOPBACK A local DTE Loopback occurs at the DTE port of the DCE and is used to test the link between the DTE and the DCE NxT1 HSSI ...

Страница 169: ...ence until CA has also been asserted by the DCE If the data communications channel requires a keep alive data pattern when the DTE is disconnected then the DCE shall supply this pattern while TA is de asserted When using the NxT1 HSSI Module 1200346L2 only in V 35 mode TA displays the status of the Request to Send RTS signal When RTS is active in a V 35 configuration Clear to Send CTS is also acti...

Страница 170: ...ill always be asserted MODULES NXT1HSSI HSSI MENUS CONFIG DSR V 35 Write security 5 Read security 5 Available only on the NxT1 HSSI V 35 Option Module P N 1200346L2 Determines the behavior of the Data Set Ready DSR signal If set to NORMAL DSR will generally be asserted when the interface is capable of passing data If set to FORCED ON DSR will always be asserted If set to REMOTE DTR the value of DS...

Страница 171: ...ed by the DTE MODULES NXT1HSSI HSSI MENUS TEST Write security 4 Read security 5 Provides access to testing functionality for the HSSI and HSSI V 35 interfaces for the NxT1 HSSI or NxT1 HSSI V 35 Option Modules MODULES NXT1HSSI HSSI MENUS TEST PORT Read security 5 Indicates the operating port number The NxT1 HSSI and NxT1 HSSI V 35 Option Modules have one available HSSI or HSSI V 35 interface MODUL...

Страница 172: ... a complete listing of menus MODULES ENET 8 INFO Read security 5 Provides information about the module part number serial number and assembly revision MODULES ENET 8 INFO PART NUMBER Read security 5 Displays the part number of the module MODULES ENET 8 INFO SERIAL NUMBER Read security 5 Displays the serial number of the module MODULES ENET 8 INFO ASSEMBLY REVISION Read security 5 Displays the asse...

Страница 173: ...The ATLAS 550 system controller automatically detects the presence of the Resource Host Module when it is installed in the system listed as RSC HOST To see the menus for the Resource Host Module via the terminal menu use the arrow keys to scroll to the MODULES menu and press Enter to access the module choices Refer to the Resource Host Module Quick Start Guide for a menu tree containing a complete...

Страница 174: ...mplete listing of menus MODULES VCOM X INFO Read security 5 Provides information about the module part number serial number and assembly revision MODULES VCOM X INFO PART NUMBER Read security 5 Displays the part number of the module MODULES VCOM X INFO SERIAL NUMBER Read security 5 Displays the serial number of the module MODULES VCOM X INFO ASSEMBLY REVISION Read security 5 Displays the assembly ...

Страница 175: ...y traffic is generated during periods of silence Both voice endpoints must agree on the silence suppression setting N A This device is not populated on the selected VCOM Resource Module AVAILABLE This resource is available for voice compression and functioning properly If a VCOM 4 Option Module is installed 4 voice compression resources will be AVAILABLE and the rest will display N A The same prin...

Страница 176: ...eives from its connected frame relay endpoint is classified into one of the following groups MODULES VCOM X CONFIG Write security 4 Read security 5 Provides diagnostic tools for suspected problems under normal operation users do not configure the packet voice devices MODULES VCOM X CONFIG CONFIGURE VCOM DEVICES Write security 4 Read security 5 Contains configuration parameters for individual VCOM ...

Страница 177: ...SETTINGS OUTPUT GAIN Write security 3 Write security 5 Output gain is applied in the receive direction Choices range from 12 dB loudest to 12 dB softest in 3 dB increments This setting takes affect immediately MODULES VCOM X CONFIG GAIN SETTINGS INPUT GAIN Write security 3 Write security 5 Input gain is applied in the transmit direction Choices range from 12 dB softest to 12 dB loudest in 3 dB inc...

Страница 178: ...CS ATLAS FRMS Read security 5 ATLAS Frames Counts every frame that the ATLAS 550 sends to or receives from the packet voice device This count indicates activity but does not indicate the actual amount of frame relay data exchanged The total number of frames handled by the packet voice device is given by the following equation See the ATLAS DROP definition below for a description of the term MODULE...

Страница 179: ... device may indicate a faulty packet voice device or an overloaded ATLAS 550 system MODULES VCOM X STATISTICS CLEAR Write security 4 Read security 5 Resets the elapsed usage time and frame counters for this packet voice device Ordinarily users won t reset these performance measurements However this feature can be useful when testing that a suspected problem has been resolved and when zeroing the v...

Страница 180: ...LES ADPCM 32 INFO Read security 5 Provides information about the module part number serial number and assembly revision MODULES ADPCM 32 INFO PART NUMBER Read security 5 Displays the part number of the module MODULES ADPCM 32 INFO SERIAL NUMBER Read security 5 Displays the serial number of the module MODULES ADPCM 32 INFO ASSEMBLY REVISION Read security 5 Displays the assembly revision of the inst...

Страница 181: ...2 CONFIG Write security 4 Read security 5 Provides diagnostic tools for suspected problems under normal operation users do not configure the packet voice devices MODULES ADPCM 32 CONFIG CONFIGURE ADPCM 32 DEVICES Write security 4 Read security 5 Contains configuration parameters for individual ADPCM 32 devices N A This device is not populated on the selected 32 Channel ADPCM Resource Module AVAILA...

Страница 182: ...he packet voice device listed On the ATLAS 550 packet voice devices are numbered 1 24 MODULES ADPCM 32 STATISTICS USAGE TIME Read security 5 Measures the total elapsed time that a packet voice device has the status BUSY The time is expressed with millisecond precision Available packet voice devices are assigned new connections using a round robin technique where all other available packet voice de...

Страница 183: ...e actual amount of packet data exchanged The following equation gives the total number of frames handled for this packet voice device by the ATLAS 550 See the ADPCM 32 DROP definition below for a description of the term MODULES ADPCM 32 STATISTICS ADPCM 32 DROP Read security 5 Counter that measures each frame dropped or discarded by ATLAS 550 during communication with the ATLAS 550 system controll...

Страница 184: ...source Module via the terminal menu use the arrow keys to scroll to the MODULES menu and press Enter to access the module choices Refer to the Nx 56 64 BONDing Resource Module Quick Start Guide for a menu tree containing a complete listing of menus MODULES BONDING INFO Read security 5 Provides information about the module part number serial number and assembly revision MODULES BONDING INFO PART NU...

Страница 185: ... the data rate of the individual bearer channels MODULES BONDING STATUS BONDED EP Read security 5 Displays the slot and port of the terminating endpoint that is using this BONDING session MODULES BONDING CONFIGURATION Write security 3 Read security 5 All of the following configurable parameters apply to the Nx 56 64 BONDing Resource Module In most applications the default values will be correct ID...

Страница 186: ...iding that the BONDING call has failed The factory default setting is sufficient for most calls to connect although when dialing overseas it may be necessary to lengthen this timer to allow for slower call routing MODULES BONDING CONFIGURATION TXDEQ TIMER SEC Write security 3 Read security 5 Specifies the length of time both endpoints attempt to equalize the network delay between the bearer channe...

Страница 187: ...oints Figure 14 These submenus include PACKET ENDPNTS PACKET CNCTS CNCTS SORT and FRAME RELAY IQ Figure 14 Packet Manager Menu PACKET MANAGER PACKET ENDPNTS Read security 5 Defines monitors and tests a packet endpoint Submenus include STATUS PERFORMANCE CONFIG TEST ENDPNT COUNT and ENDPNTS SORT NO STAGGER There is no delay between the call dialing of a BONDING session 500 MS Wait approximately sec...

Страница 188: ... PPP indicates this packet endpoint is configured for the Point to Point Protocol SDLC indicates this packet endpoint is configured for SDLC signaling PACKET MANAGER PACKET ENDPNTS STATUS SIG ROLE Read security 5 Displays the frame relay signaling role for this packet endpoint The following options indicate the signaling role for this packet endpoint These settings are not applicable for PPP PACKE...

Страница 189: ...e packet endpoint stays in this state only when the physical line is down INITIAL This is the first state of LCP negotiation If the packet endpoint is connected to a physical port in the DEDICATED MAP this state will usually transition to the STARTING state to begin the PPP negotiation STARTING The packet endpoint stays in this state only when the physical line is down REQ SENT The packet endpoint...

Страница 190: ...layer 2 performance statistics The statistics fields for frame relay reflect the total count since last cleared The available statistic information is discussed below SDLC signaling is only available using the Legacy Data Option Module P N 1200342L1 TX PACKETS Total number of frame relay packets transmitted through this packet endpoint including both user data on all PVCs and signaling RX PACKETS ...

Страница 191: ...nformation is discussed below LINK INTEGRITY STATUS TX Number of link integrity polls transmitted by this packet endpoint LINK INTEGRITY STATUS RX Number of link integrity polls received by this packet endpoint CLEAR COUNTERS Clears all values in this submenu TX PACKETS Read security 5 Total number of HDLC or SDLC packets transmitted through this packet endpoint RX PACKETS Write security 3 Read se...

Страница 192: ...security 3 Read security 5 Alphanumeric characters up to 16 characters to create a user defined name for the sublink PVC DLCI Write security 3 Read security 5 Local address for each PVC as assigned by the carrier STATE Write security 3 Read security 5 Indicates if this particular sublink PVC has been defined as active by a full status poll and also indicates if the PVC is in backup mode ACTIVE PVC...

Страница 193: ...ay provider or the circuit ID STATISTICS Write security 3 Read security 5 Provides additional information as follows on the individual sublink RESET COUNTERS Write security 3 Read security 5 Resets all sublink counters FECN COUNT Write security 3 Read security 5 Total number of FECN bits received on this PVC BECN COUNT Write security 3 Read security 5 Total number of BECN bits received on this PVC...

Страница 194: ... following options indicate the signaling role of this packet endpoint OFF The remote device does not support frame relay signaling AUTO Detects the role of the device on the other end of the circuit and automatically sets this packet endpoint to the appropriate value BOTH Operates in NNI mode NETWORK Acts as the network side of the UNI interface USER Acts as the user side of the UNI interface SIG...

Страница 195: ...OW SIZE configuration parameters should be left in the default state Use caution when changing these parameters NET POLL RESPONSE TIMEOUT T392 Write security 3 Read security 5 Determines how long this packet endpoint will wait without receiving a poll before declaring the poll bad Ensure that this timer is greater than the T391 on the user side of the UNI otherwise erratic behavior will result NET...

Страница 196: ... authenticate the peer only using one of the encrypted authentication protocols EAP is selected when you will authenticate the peer only using the EAP authentication protocol TX METHOD Write security 3 Read security 5 This field displays a list of the methods that we will allow the peer to authenticate us with This is of use when a peer wants to do PAP just to get your password None is selected wh...

Страница 197: ...ing for all unknown protocols received on this link MAX CONFIG Write security 3 Read security 5 This value is the number of unanswered configuration requests that should be transmitted before giving up on negotiation The default value is 10 MAX TIMER Write security 3 Read security 5 This value is the number of seconds to wait between unanswered configuration requests The default value is 2 seconds...

Страница 198: ... when the first poll is sent and will be restarted when the next poll is sent SLOW POLL RATIO Write security 3 Read security 5 Configures the ATLAS 550 to send polls to unresponsive remote units at a slower rate than normal The number entered sets the ration When a remote unit is polled repeatedly and no answer is received the ATLAS 550 will move the unit from the normal poll interval to the slow ...

Страница 199: ... a voltage change and zeroes with no voltage change NRZI encoding is also known as transition coding NAME Write security 3 Read security 5 User definable name for the DLCI DLCI Write security 3 Read security 5 Local address for each PVC as assigned by the carrier QOS Write security 3 Read security 5 Quality of service These values can be used to assign a guaranteed amount of bandwidth available fo...

Страница 200: ... switch Set DLCI STATE to AUTO for normal operation FORCE ACTIVE This DLCI disregards the status as reported from the switch and reports Active to all packet endpoints within ATLAS 550 FORCE INACTIVE Reports status as DOWN to all packet endpoints within ATLAS 550 DIAGNOSTIC MODE Write security 3 Read security 5 Controls operation of PVC testing options To allow the far end to measure delay select ...

Страница 201: ...Visible only if ENABLE BACKUP SUPPORT is set to YES Selects BACKUP PACKET ENDPT that contains the BACKUP SUBLINK to be tied to this sublink BACKUP SUBLINK Write security 3 Read security 5 Visible only if ENABLE BACKUP SUPPORT is set to YES Selects the BACKUP SUBLINK to be tied to this sublink PRIMARY PACKET ENDPT Write security 3 Read security 5 Visible only for Backup packet endpoints Selects the...

Страница 202: ...es switching options for LMI signaling Select YES to switch to backup if LMI signaling is inactive on the primary link otherwise select NO SWITCH ON BACKUP ACTIVE Write security 3 Read security 5 Provides switching options if the backup sublink goes active Select YES to switch to backup if the backup sublink goes active otherwise select NO BACKUP DELAY IN SECONDS Write security 3 Read security 5 T...

Страница 203: ... security 3 Read security 5 Displays the protocol running on the packet endpoint PACKET MANAGER PACKET ENDPNTS TEST SUBLINK FRAME RELAY Write security 3 Read security 5 Displays test menus for the packet endpoint sublinks The menus vary depending on the protocol Testing is not supported on TBOP or PPP 1 Packet connection in the first dedicated map 2 Packet connection in the second dedicated map 3 ...

Страница 204: ...ured for continuous in band delay measurement The following RESULTS menu accumulates these measurements STOP Write security 3 Read security 5 The fixed duration TEST is running The following DURATION field shows the time remaining in the current test DURATION Read security 5 Shows the duration in seconds for the fixed duration test RESULTS MN AV MX DLY Read security 5 Displays the minimum average ...

Страница 205: ...S connects upper layer protocols from packet endpoint to packet endpoint You can think of it as a dedicated map for virtual ports rather than physical ports ECHO PKT DROPPED Read security 5 Displays the total number of packets lost in the receiving direction traveling from the remote ADTRAN frame relay device to the ATLAS RMT PKT DROPPED Read security 5 Displays the total number of packets lost in...

Страница 206: ...rity 5 If the TO PEP packet endpoint supports sublinks the available sublinks are shown within this menu which includes the ROUTER option PACKET MANAGER PACKET CNCTS PROTOCOL Write security 3 Read security 5 Selects the protocols for this packet connection Selecting the protocols on each individual connection allows the mixing of data from multiple sources onto a single PVC Available protocols inc...

Страница 207: ...Use the submenus NAME ENABLE ALL SUBLINKS and SUBLINKS to configure the individual ports PACKET MANAGER FRAME RELAY IQ PORT ENABLES NAME Read security 5 Displays the port number and name PACKET MANAGER FRAME RELAY IQ PORT ENABLES ENABLE Write security 2 Read security 5 Enables and disables IQ statistics gathering for the port identified in NAME PACKET MANAGER FRAME RELAY IQ PORT ENABLES ALL SUBLIN...

Страница 208: ...d 30 MINUTES PACKET MANAGER FRAME RELAY IQ CONFIG MAX DAYS Write security 2 Read security 5 Defines the number of history day intervals to keep Maximum entry is dependent on the MAX INTERVALS setting PACKET MANAGER FRAME RELAY IQ CONFIG MAX INTERVALS Write security 2 Read security 5 Defines the number of history intervals to keep Maximum entry is dependent on the MAX DAYS setting PACKET MANAGER FR...

Страница 209: ...ay AVG RX UTIL Read security 5 The average utilization the port received for the interval or day TX FRAMES Read security 5 The number of frames the port transmitted for the interval or day TX BYTES Read security 5 The number of bytes the port transmitted for the interval or day MAX TX THRU Read security 5 The maximum throughput the port transmitted for the interval or day AVG TX THRU Read security...

Страница 210: ...eceived with protocol violations SIGNAL T O Read security 5 The number of PVC signal time outs Either T391 seconds elapsed without receiving a response to a poll or T392 seconds elapsed without receiving a poll SIG STATE CHG Read security 5 The number of state changes for the PVC signaling protocol This number includes transitions from down state to up state and vice versa RX FULL STAT Read securi...

Страница 211: ...5 The number of frames received without proper flag termination CRC ERROR Read security 5 The number of frames received with CRC errors OCTET ALIGN Read security 5 The number of frames received with a bit count not divisible by eight LENGTH ERROR Read security 5 The number of frames received that are less than 5 bytes or greater than 4500 bytes EA VIOLATION Read security 5 The number of frames rec...

Страница 212: ...The number of frames the port received for the interval or day RX BYTES Read security 5 The number of bytes the port received for the interval or day MAX RX THRU Read security 5 The maximum throughput the port received for the interval or day AVG RX THRU Read security 5 The average throughput the port received for the interval or day MAX RX UTIL Read security 5 The maximum utilization the port rec...

Страница 213: ...ay MAX TX UTIL Read security 5 The maximum utilization the port transmitted for the interval or day AVG TX UTIL Read security 5 The average utilization the port transmitted for the interval or day PVC IA TIME Read security 5 Time in seconds the PVC has been in the inactive state for the interval or day RX FECN Read security 5 The number of FECNs the PVC has received for the interval or day TX FECN...

Страница 214: ... of lost frames on the PVC for the interval or day RMT LOST FRMS Read security 5 The number of remote lost frames on the PVC for the interval Applies only if IN BAND SEQUENCE NUMBER is ENABLED on the PVC RX BURST SEC Read security 5 The number of bursty seconds the PVC received for the interval or day TX BURST SEC Read security 5 The number of bursty seconds the PVC transmitted for the interval or...

Страница 215: ...nfig SDLC on page 198 the IN BAND DELAY MEASUREMENT option for the PVC or if PVC diagnostics are being performed MAX FRAME DLY Read security 5 The maximum delay in milliseconds on the PVC for the interval or day Applies only if IN BAND DELAY MEASUREMENT is ENABLED see Packet Manager Packet Endpnts Config Config SDLC on page 198 the IN BAND DELAY MEASUREMENT option for the PVC or if PVC diagnostics...

Страница 216: ...g functions within the ATLAS are configured and monitored from the ROUTER menu Figure 15 Router Menu IP Selected ROUTER IP STATIC ROUTES Write security 2 Read security 2 The STATIC ROUTES menu manages static IP routes You can create modify and delete routes using this menu ROUTER IP STATIC ROUTES IP ADDRESS Write security 2 Read security 2 Defines the IP address of the host or network device being...

Страница 217: ...e selected network Normally the cost is based on the available bandwidth ROUTER IP STATIC ROUTES ENABLED Write security 2 Read security 2 Adds a static route to the router ROUTER IP STATIC ROUTES ADVERTISE Write security 2 Read security 2 When set to YES this static route is advertised over all interfaces on which a route advertisement protocol e g RIP is enabled When set to NO this is a private r...

Страница 218: ... the contents of the ATLAS routing table All static and discovered routes are displayed from this menu ROUTER IP ROUTES IP ADDRESS Read security 2 Displays the IP address of the destination host or network ROUTER IP ROUTES NETMASK Read security 2 Displays the subnet mask applied to the destination address ROUTER IP ROUTES GATEWAY Read security 2 Displays the IP address of the next hop router or ho...

Страница 219: ...used ROUTER IP ROUTES COST Read security 2 Displays the total cost of sending a packet to the specified network Normally the cost is based on the available bandwidth ROUTER IP ROUTES TTL Read security 2 Displays the number of seconds until the address is removed from table A value of 999 means the route is static ROUTER IP INTERFACES Write security 2 Read security 2 The INTERFACES menu configures ...

Страница 220: ...rite security 2 Read security 2 This menu is only present for frame relay network interfaces and it is only selectable when IARP is disabled Use this menu to specify the IP address of the device on the other end of the virtual circuit If that IP address is non zero a static route to the far end network will be added using the interface SUBNET MASK If 0 0 0 0 has been specified for the SUBNET MASK ...

Страница 221: ... will not be visible PROTOCOL Write security 2 Read security 2 Only visible if RIP is enabled Sets the version of RIP being used on this interface The options are RIP V1 and RIP V2 If RIP V2 is used a new menu AUTHENTICATION opens If RIP V2 is used a user defined secret may have to be created METHOD Write security 2 Read security 2 Only visible if RIP is enabled Defines the method used to send RIP...

Страница 222: ... the fact that a network has been further subnetted ROUTER IP GLOBAL Write security 2 Read security 2 Provides a way to configure various settings for the Ethernet port The following menus are available for review and editing ROUTER IP GLOBAL DEFAULT GATEWAY Write security 2 Read security 2 Defines or changes the default gateway Enter the default gateway address by entering a decimal number into t...

Страница 223: ...ecurity 2 Read security 2 Specifies the size in bytes of the data portion of the ping request The default value is 64 bytes and the maximum size is 1024 bytes ROUTER IP PING TIMEOUT Write security 2 Read security 2 Specifies the time in milliseconds to wait for the ping reply before timing out The default timeout is three seconds and the maximum timeout value is ten seconds ROUTER IP PING ROUND TR...

Страница 224: ...T Write security 2 Read security 2 Allows a user to open a Telnet session to any device listed in the ATLAS 550 route table ROUTER IP TELNET CLIENT ADDRESS Write security 2 Read security 2 Defines the IP address assigned to the remote unit you are trying to connect to ROUTER IP TELNET CLIENT ESCAPE CHAR Write security 2 Read security 2 Defines the Telnet client escape character Typing the combinat...

Страница 225: ...sums version number mismatch other format errors time to live exceeded errors discovered in processing their IP options etc INADDRERRORS The number of input datagrams discarded because the IP address in their IP header s destination field was not a valid address to be received at this ATLAS 550 This count includes invalid addresses e g 0 0 0 0 and addresses of unsupported Classes e g Class E For e...

Страница 226: ...ved fragments are held while they are awaiting reassembly at this ATLAS 550 REASMREQDS The number of IP fragments received which needed to be reassembled at this ATLAS 550 REASMOKS The number of IP datagrams successfully reassembled REASMFAILS The number of failures detected by the IP reassembly algorithm for whatever reason timed out errors etc Note that this is not necessarily a count of discard...

Страница 227: ...UTERRORS OUTERRORS The number of ICMP messages which this ATLAS 550 did not send due to problems discovered within ICMP such as a lack of buffers This value should not include errors discovered outside the ICMP layer such as the inability of IP to route the resultant datagram In some implementations there may be no types of error which contribute to this counter s value OUTDESTUNREACHS The number ...

Страница 228: ...ns is dynamic this object should contain the value 1 ACTIVEOPENS The number of times TCP connections have made a direct transition to the SYN SENT state from the CLOSED state PASSIVEOPENS The number of times TCP connections have made a direct transition to the SYN RCVD state from the LISTEN state ATTEMPTFAILS The number of times TCP connections have made a direct transition to the CLOSED state fro...

Страница 229: ... a relay agent ROUTER IP UDP RELAY RELAY TABLE Write security 2 Read security 2 Available only when UDP Relay is ENABLED Lists up to four relay destination servers RELAY TABLE 0 3 Each server can be configured using the following menus ENABLE IP and UDP Table 9 UDP Statistics Name Description INDATAGRAMS The total number of UDP datagrams delivered to UDP users NOPORTS The total number of received ...

Страница 230: ...urity 2 Enables disables this field Select either STANDARD or SPECIFIED DISABLE is not used STANDARD DEFAULT Relays any of the following standard UDP protocols DHCP TFTP DNS NTP Network Time Protocol port 123 NBNS NetBIOS Name Server port 137 NBDG Net BIOS Datagram port 138 and BootP SPECIFIED Specifies the UDP port 1 to 65 535 in the UDP Port columns maximum of three per server IP Write security ...

Страница 231: ...lpha numeric characters including spaces and special characters To edit the name press Enter and type in the new name DEDICATED MAPS CREATE EDIT MAPS SORT TO FROM Write security 3 Read security 5 Specifies sort order based on the end points set in CONNECTS FROM CONFIG and CONNECTS TO CONFIG You can also turn OFF this option The sort feature is helpful when you are attempting to find a particular c...

Страница 232: ...d press Enter If a PKTENDPT or PKTVOICE endpoint is selected for the TO SLOT SERVICE field the available packet endpoints or packet voice endpoints will display in the drop down menu after pressing Enter DEDICATED MAPS CREATE EDIT MAPS CONNECTS FROM CONFIG Write security 3 Read security 5 Specifies the configuration for the FROM connection The selections displayed in this field are based on the ty...

Страница 233: ... to the T1 PRI Network Interface and Dual Quad T1 PRI Option Modules depending on the application DS0 SELECTION Write security 3 Read security 5 Defines DS0s for a T1 port Use this field to define the DS0s for this connection You can enter the DS0s in several ways For example to enter DS0s one through five enter 1 5 For DS0s one and five enter 1 5 DS0 AVAILABLE Write security 3 Read security 5 Ind...

Страница 234: ...to ATLAS 550 the type of signaling being used on the trunk E M LS GS NETWORK OR USER SW56 or CUSTOM T1 TRUNK CONDITIONING STATE Write security 3 Read security 5 Available only when T1 TRUNK CONDITIONING SERVICE is enabled Defines the final fault signaling state IDLE Used for one way trunks that is for outgoing or incoming calls only not both SEIZED Used for two way trunks Prevents connected equipm...

Страница 235: ...or example to enter TS0s one through five enter 1 5 For TS0s one and five enter 1 5 TS0 AVAILABLE Write security 3 Read security 5 Indicates which TS0s of the E1 are assigned TS0 assignment is based on the following items DIGIT 0 9 This TS0 is available The digit that displays in this field represents the last digit of the TS0 number This TS0 has been requested for this connection but the TS0 is n...

Страница 236: ... by a continuous transmission signaling the final condition as chosen by the user Set the E1 TROUBLE CODE SERVICE field to OFF or VOICE T1 TROUBLE CODE VALUE Write security 3 Read security 5 Displays the Hex value of the 2 5 second pre alarm transmission PORTS Write security 3 Read security 5 Defines ports to be used for this connection PORTS AVAILABLE Write security 3 Read security 5 Indicates wh...

Страница 237: ...ions become available that are E M trunk specific This option is sometimes referred to as TANDEM conversion The following submenu items become visible when E M CONVERSION is ENABLED E M SUPERVISION Write security 3 Read security 5 Available only when E M CONVERSION is enabled Configures the E M trunk as either Immediate start or Wink start This configuration is for the Rx and Tx direction When DNI...

Страница 238: ...ON is enabled Defines the time we delay after transmitting a wink in response to the 2W going off hook after ringing before we send off hook in the RBS signaling This field is only valid for E M conversion The timing is as follows The following submenu item becomes visible when DNIS DELAY is activated DNIS WINK TIMEOUT Write security 3 Read security 5 When DNIS DELAY is ENABLED a wink will be retu...

Страница 239: ... This DS0 is used in the switched DIAL PLAN and conflicts with this connection N This DS0 is already used in this DEDICATED MAP N This DS0 is already used in this DEDICATED MAP and conflicts with this connection SIGNALING METHOD Write security 3 Read security 5 Defines the mode of operation of the selected voice port The signaling on the T1 mapped to this voice port must match The options include ...

Страница 240: ...ing selections may apply to the Dual USSI Option Module depending on the application DS0 SELECTION Write security 3 Read security 5 Defines DS0s for an Nx port Use this field to define the DS0s for this connection This field only applies to Nx to Nx or Nx to Pkt Endpt connections DS0 RATE Write security 3 Read security 5 Sets the DS0 rate to either 56 or 64 kbps DS0 SELECTION Write security 3 Read...

Страница 241: ...y 5 Enters the dedicated map connections Press Enter to activate the submenus PORTS Write security 3 Read security 5 Defines ports to be used for this connection PORTS AVAILABLE Write security 3 Read security 5 Indicates which ports of the module are assigned Port assignment is based on the following items DIGIT 0 9 This DS0 is available The digit that displays in this field represents the last di...

Страница 242: ...nt is based on the following items DIGIT 0 9 This DS0 is available The digit that displays in this field represents the last digit of the DS0 number This DS0 has been requested for this connection but the DS0 is not yet activated for this port This DS0 is used by this port in this connection and is currently activated S This DS0 is used in the switched DIAL PLAN S This DS0 is used in the switched ...

Страница 243: ...ule T1 TROUBLE CODE VALUE Write security 3 Read security 5 Available only when T1 TROUBLE CODE SERVICE is enabled Displays the Hex value of the 2 5 second pre alarm transmission SYNC ASYNC Write security 3 Read security 5 Configures the port for either synchronous or asynchronous data transmission The mode of operation depends on the protocol selected in the PACKET MANAGER menus INTERFACE TYPE Wri...

Страница 244: ...e security 3 Read security 5 Press Enter and select the appropriate packet endpoint to assign the endpoint to a physical port DEDICATED MAPS PKT ENDPT CREATE EDIT MAPS CONNECTS TO FROM CONFIG Write security 3 Read security 5 Specifies the configuration for the TO FROM connection The following selections apply to the packet endpoint TD CLOCK SOURCE Write security 3 Read security 5 Configures the in...

Страница 245: ...int from the drop down list DEDICATED MAPS PKT VOICE CREATE EDIT MAPS CONNECTS TO FROM CONFIG Write security 3 Read security 5 Specifies the configuration for the TO FROM connection The following selections apply to the PKT VOICE connections RECEIVE IDLE CODE Write security 3 Read security 5 Defines the idle code either marks or flags the ATLAS 550 should expect on the selected packet endpoint DLC...

Страница 246: ...ust agree on the selected compression algorithm The ADPCM 32 Resource Module will not interoperate with the FSU and Express series products SILENCE SUPPRESSION Write security 3 Read security 5 Reduces the total system bandwidth load by preventing ATLAS from sending frames containing a special silence code during periods of silence Both endpoints must agree to use silence suppression By default sil...

Страница 247: ...status of all circuits configured for dedicated circuit backup see Figure 17 Figure 17 Circuit Status Menu CIRCUIT STATUS FROM Read security 5 Indicates the slot port and name of the endpoint configured for backup CIRCUIT STATUS MAN MANUAL BACKUP Write security 3 Read security 5 This activator forces a link in out of backup FB Force Backup FR Force Restore ...

Страница 248: ...curity 5 Not visible until a circuit has been tested Displays the date and time of the last test call made through this dedicated dial backup circuit FB Backup was forced through the interface menu FR Restore was forced through the interface menu PRIMARY The link is active DIALING Attempting to dial the backup link BACKUP FAILED Exceeded MAX NUM REDIALS RETRY DIAL NUM Will retry backup dialing in ...

Страница 249: ...ST TEST STATUS Read security 5 Displays the status of the last test call made through this dedicated dial backup circuit The following status messages may display CIRCUIT STATUS TEST PASS FAIL Read security 5 Displays the number of successful and unsuccessful test calls made through this dedicated dial backup circuit CIRCUIT STATUS TEST TEST NOW Write security 5 Read security 5 Press to initiate a...

Страница 250: ...terminate a connection from the network DIAL PLAN NETWORK TERM SLOT SVC Write security 3 Read security 5 Selects the ATLAS 550 slot or service that terminates a network connection DIAL PLAN NETWORK TERM PORT PEP Write security 3 Read security 5 Selects the ATLAS 550 port or packet endpoint that terminates a network connection In applications where two ATLAS 550 units are used in a point to point c...

Страница 251: ...dpoint originated the call SRC ID may be entered with the usual wild card entries except The default ID for all source endpoints all accept numbers is 0 This results in all calls being routed based on the dialed number DIAL PLAN NETWORK TERM OUT ACCEPT ACCEPT NUMBER Write security 3 Read security 5 Designates which numbers this endpoint passes on toward the network The accept list may consist of m...

Страница 252: ...cted call type regardless of the actual incoming call type The default selection AS RECEIVED effectively disables the feature by using the actual call type Other options include DATA 64K and DATA 56K DIAL PLAN NETWORK TERM OUT REJ Write security 3 Read security 5 Defines parameters for outgoing calls that ATLAS 550 will not send to the network DIAL PLAN NETWORK TERM OUT REJ REJECT NUMBER Write sec...

Страница 253: ...ead security 5 The substitution template allows the ATLAS 550 to select calls based on telephone number and substitute a user defined number for the received digits after the call has been processed by the switchboard Substitution templates are created for each entry in the DIAL PLAN DIAL PLAN NETWORK TERM SUBST TEMPL ORIGINAL Write security 3 Read security 5 Designates the number s to be the sear...

Страница 254: ...VC Write security 3 Read security 5 Selects the ATLAS 550 slot or service that terminates a user connection DIAL PLAN USER TERM PORT PEP Write security 3 Read security 5 Selects the ATLAS 550 port or packet endpoint that terminates a user connection X Any single digit N Any single digit 2 through 9 Any number of digits of any value 9 This specific number 1 2 3 A single digit in this group Wildcard...

Страница 255: ... entries except The default ID for all source endpoints all accept numbers is 0 This results in all calls being routed based on the dialed number DIAL PLAN USER TERM IN ACCEPT ACCEPT NUMBER Write security 3 Read security 5 Designates which numbers this endpoint will accept terminate from the network The accept list may consist of multiple entries The numbers are defined using the following wildcar...

Страница 256: ... will not send to the network DIAL PLAN USER TERM OUT REJ REJECT NUMBER Identifies which numbers this endpoint will not pass on toward the network Use when the outgoing call filter is different for different users sharing this endpoint The wildcards are identical as in OUT ACCEPT see Dial Plan Network Term Out Accept on page 251 DIAL PLAN USER TERM OUT REJ DATA 64K DATA 56K AUDIO SPEECH Rejects ou...

Страница 257: ... the number s to be the search criteria for the substitution template The pattern can be a specific number or wildcards can be used as part of the number specification Example 963 812 012 would be 963 8120 to 963 8122 DIAL PLAN USER TERM SUBST TEMPL SUBSTITUTED Write security 3 Read security 5 Designates the number to be substituted for the number s defined in the ORIGINAL field The pattern can be...

Страница 258: ...e Enter your international country code using only digits For the United States enter 1 DIAL PLAN GLOBAL PARAM AREA OR CITY CODE Write security 3 Read security 5 The local area code Use for sending caller ID to the network DIAL PLAN GLOBAL PARAM NBR COMPLETE TEMPLATES Write security 3 Read security 5 Sets completed number patterns for outgoing calls so that ATLAS 550 recognizes when the phone numb...

Страница 259: ...n you press Enter maximum of 40 characters A pattern for a normal long distance call for example would be 1 NXX NXX XXXX Note that the symbols and space are not required and are only used to improve the readability of this example DIAL PLAN GLOBAL PARAM NUMBER TYPE TEMPLATES NUMBER TYPE Lists valid selections when you press Enter Selections include LOCAL NATIONAL INTERNATIONAL PRIVATE and UNKNOWN ...

Страница 260: ...l menu items in this section listed as T1 PRI apply to T1 Network and Dual Quad Module interfaces configured in the DIAL PLAN DIAL PLAN T1 PRI NETWORK TERM PRI Write security 3 Read security 5 This menu allows the user to define option parameters for ports which terminate a PRI connection from the network DIAL PLAN T1 PRI NETWORK TERM PRI IFCE CONFIG PRI Write security 3 Read security 5 Specifies ...

Страница 261: ...digits are always sent to the network Leading ones if present are stripped out and the area code provisioned under DIAL PLAN GLOBAL PARAMETERS is added if only seven digits are supplied This action may be required in areas with ten digit local dialing ISDN SUBSCRIBER PREFERRED Examines the incoming number and if seven digits are received or if a ten digit number is received with an area code that ...

Страница 262: ...ment be sent to the network during call setup DIAL PLAN T1 PRI NETWORK TERM PRI IFCE CONFIG PRI CALLED DIGITS TRANSFERRED Write security 3 Read security 5 Some PRI switches may be provisioned to send only a portion of the called number like DID This menu item allows the ATLAS 550 to know how many digits to expect choose from NONE THREE FOUR SEVEN and ALL The default is ALL and would almost always ...

Страница 263: ... that all calls that originate from Port 1 of the ATLAS 830 in Slot 1 be switched to Port 2 of that same module Assign a unique SOURCE ID e g 7 to Port 1 of the module and then configure Port 2 to only accept calls from that unique SOURCE ID 7 DIAL PLAN T1 PRI NETWORK TERM PRI IFCE CONFIG PRI SWAP ANI DNIS Write security 3 Read security 5 Swaps the ANI and DNIS numbers received from the network AN...

Страница 264: ...t on page 251 and OUT REJECT see Dial Plan Network Term Out Rej on page 252 DIAL PLAN T1 PRI NETWORK TERM RBS IFCE CONFIG RBS NUMBER OF DS0S Write security 3 Read security 5 Specifies the number of DS0s ATLAS 550 uses for this endpoint DIAL PLAN T1 PRI NETWORK TERM RBS IFCE CONFIG RBS DS0S AVAILABLE Write security 3 Read security 5 Indicates which DS0s of the T1 have been defined in this switched ...

Страница 265: ...figured for FEATURE GROUP D Defines to the ATLAS 550 the format in which to receive the incoming digits Choices NORMAL if no digits are to be received ANI DNIS to receive both ANI and DNIS DNIS to receive DNIS only ANI to receive ANI only DIAL PLAN T1 PRI NETWORK TERM RBS IFCE CONFIG RBS WINK AFTER ANI DNIS Write security 3 Read security 5 Displayed only if SIGNALING METHOD is configured for FEATU...

Страница 266: ...ty 3 Read security 5 When the network connection does not provide DID digits the ATLAS 550 must be given a number to use to determine which user endpoint should receive the incoming call TRUNK NUMBER displays only when DID is set to DISABLED Example To connect an incoming DS0 trunk to an endpoint with the accept number of 963 8615 set the trunk number to 963 8615 DIAL PLAN T1 PRI NETWORK TERM RBS ...

Страница 267: ...ves an incoming call on DS0 17 The switchboard looks for an interface who has matching accept criteria to the number it received A match is found on interface Z that has DS0 SELECTION set to ALIGNED This causes interface Z to only process the call if it has DS0 17 available If all matching interfaces have DS0 SELECTION set to ALIGNED and none of those interfaces have DS0 17 available then a busy o...

Страница 268: ...f the most significant digits MSD of a dialed number prior to being forwarded out of the port Example A network port could be set to accept all calls beginning with 9 9 and then with STRIP MSD set to 1 all digits would be sent toward the network except the leading 9 DIAL PLAN T1 PRI USER TERM PRI IFCE CONFIG PRI NETWORK SPECIFIC FACILITY VOICE AND DATA Write security 3 Read security 5 Enables the ...

Страница 269: ...ndpoint is a function of which endpoint originated the call DEFAULT VALUE 0 Zero is the default ID for all endpoints and all accept numbers With default values all calls are routed based only on the dialed number Multiple endpoints can have the same SOURCE ID When creating the CALL ACCEPT list specify a SOURCE ID s as well as a dialed number or range of dialed numbers to accept Example An applicat...

Страница 270: ...DIAL PLAN T1 PRI USER TERM RBS IFCE CONFIG RBS Write security 3 Read security 5 Specifies the configuration parameters for the endpoint DIAL PLAN T1 PRI USER TERM RBS IFCE CONFIG RBS FIRST DS0 Write security 3 Read security 5 Defines the first DS0 for this endpoint The ATLAS 550 uses DS0s starting with this selection to send and receive calls to and from the network The outgoing calls which are al...

Страница 271: ...I only DIAL PLAN T1 PRI USER TERM RBS IFCE CONFIG RBS FGD RX SEQUENCE Write security 3 Read security 5 Displayed only if SIGNALING METHOD is configured for FEATURE GROUP D Defines the format in which to receive the incoming digits Choices NORMAL if no digits are to be received ANI DNIS to receive both ANI and DNIS DNIS to receive DNIS only ANI to receive ANI only DIAL PLAN T1 PRI USER TERM RBS IFC...

Страница 272: ...ED Write security 3 Read security 5 Defines the number of digits sent to ATLAS 550 from the network if DID is used This option only displays if DID is set to ENABLED DIAL PLAN T1 PRI USER TERM RBS IFCE CONFIG RBS STRIP MSD Write security 3 Read security 5 Strips a selected quantity choose from NONE 1 2 and 3 of the most significant digits MSD of a dialed number prior to being forwarded out of the ...

Страница 273: ...his endpoint is initiated goes off hook DIAL PLAN T1 PRI USER TERM RBS IFCE CONFIG RBS DS0 SELECTION Write security 3 Read security 5 Determines how the ATLAS 550 switchboard uses DS0s for call routing Example The unit receives an incoming call on DS0 17 The switchboard looks for an interface who has matching accept criteria to the number it received A match is found on interface Z that has DS0 SE...

Страница 274: ... DS0s starting with this selection to send and receive calls to and from the network PSTN The outgoing calls which are allowed or restricted over these DS0s are set by OUT ACCEPT see Dial Plan Network Term Out Accept on page 251 and OUT REJECT see Dial Plan Network Term Out Rej on page 252 DIAL PLAN E1 PRA NETWORK TERM PRA IFCE CONFIG PRA NUMBER OF DS0S Write security 3 Read security 5 Specifies t...

Страница 275: ... IFCE CONFIG PRA SOURCE ID Write security 3 Read security 5 Simplifies the creation of a dial plan in applications where the criterion for switching calls to a certain endpoint is a function of which endpoint originated the call DEFAULT VALUE 0 Zero is the default ID for all endpoints and all accept numbers With default values all calls are routed based only on the dialed number Multiple endpoints...

Страница 276: ...nt DIAL PLAN E1 PRA USER TERM PRA IFCE CONFIG PRA SWITCH TYPE Write security 3 Read security 5 Defines the type of PRA switch that the ATLAS 550 emulates If connected to another ATLAS 550 both need to be set to the same switch type The following option is available ETSI DSS1 DIAL PLAN E1 PRA USER TERM PRA IFCE CONFIG PRA FIRST DS0 Write security 3 Read security 5 Defines the first DS0 for this end...

Страница 277: ...RA USER TERM PRA IFCE CONFIG PRA OUTGOING CALLER ID Write security 3 Read security 5 Defines the number to use to provide Caller ID to the network for outgoing calls sent through this endpoint Choose from SEND AS PROVIDED SUBSTITUTE IF NOT PRESENT or SUBSTITUTE ALWAYS DIAL PLAN E1 PRA USER TERM PRA IFCE CONFIG PRA SOURCE ID Write security 3 Read security 5 Simplifies the creation of a dial plan in...

Страница 278: ...RI DBU Network and Quad BRI U Module interfaces configured in the DIAL PLAN DIAL PLAN U BRI NETWORK TERM Write security 3 Read security 5 This menu allows the user to define option parameters for ports which terminate a BRI connection from the network DIAL PLAN U BRI NETWORK TERM IFCE CONFIG Write security 3 Read security 5 Specifies the configuration parameters for the endpoint DIAL PLAN U BRI NE...

Страница 279: ...t could be set to accept all calls beginning with 9 9 and then with STRIP MSD set to 1 all digits would be sent toward the network except the leading 9 PHONE NUMBER Write security 3 Read security 5 The phone number s assigned to this BRI phone line SPID NUMBER Write security 3 Read security 5 This entry must match the SPID number s which has been set in the network s ISDN switch or in the PBX for ...

Страница 280: ...RI NETWORK TERM IFCE CONFIG SWAP ANI DNIS Write security 3 Read security 5 Swaps the ANI and DNIS numbers received from the network ANI Automatic Number Identification is the billing number of the calling party and DNIS Dialed Number Identification Service is the called party number DIAL PLAN U BRI USER TERM Write security 3 Read security 5 This menu allows the user to define option parameters for...

Страница 281: ... well as a dialed number or range of dialed numbers to accept Example An application requires that all calls that originate from Port 1 of the ATLAS 550 in Slot 1 be switched to Port 2 of that same module Assign a unique SOURCE ID e g 7 to Port 1 of the module and then configure Port 2 to only accept calls from that unique SOURCE ID 7 SPID NUMBER Write security 3 Read security 5 This entry must ma...

Страница 282: ...urity 5 Specifies the configuration parameters for the endpoint DIAL PLAN FXS USER TERM IFCE CONFIG PORTS AVAILABLE Write security 3 Read security 5 Indicates which ports of the Quad Octal FXS Option Modules have been defined in this switched endpoint indicated by in another switched endpoint indicated by s or in a DEDICATED MAP indicated by n This field is read only The following characters may d...

Страница 283: ...ed DIAL PLAN FXS USER TERM IFCE CONFIG DID DIGITS TRANSFERRED Write security 3 Read security 5 Defines the number of digits sent to ATLAS 550 from the network if DID is used This option only displays if DID is set to ENABLED DIAL PLAN FXS USER TERM IFCE CONFIG CALLER ID NUMBER Write security 3 Read security 5 Defines the number the ATLAS 550 uses to provide caller ID to the network for outgoing ca...

Страница 284: ...mong the available ports on the module Example The unit receives an incoming call on Port 3 The switchboard looks for an interface who has matching accept criteria to the number it received A match is found on interface Z that has PORT SELECTION set to ALIGNED This causes interface Z to only process the call if it has Port 3 available If all matching interfaces have PORT SELECTION set to ALIGNED a...

Страница 285: ...AL PLAN FXO NETWORK TERM IFCE CONFIG Write security 3 Read security 5 Specifies the configuration parameters for the endpoint DIAL PLAN FXO NETWORK TERM IFCE CONFIG PORTS AVAILABLE Write security 3 Read security 5 Indicates which ports of the Quad Octal FXO Option Modules have been defined in this switched endpoint indicated by in another switched endpoint indicated by s or in a DEDICATED MAP indi...

Страница 286: ...BLED then the following information must be defined DIAL PLAN FXO NETWORK TERM IFCE CONFIG DID DIGITS TRANSFERRED Write security 3 Read security 5 Defines the number of digits sent to ATLAS 550 from the network if DID is used This option only displays if DID is set to ENABLED DIAL PLAN FXO NETWORK TERM IFCE CONFIG DID PREFIX Write security 3 Read security 5 Visible only if DIRECT INWARD DIALING is...

Страница 287: ...o only accept calls from that unique SOURCE ID 7 DIAL PLAN FXO NETWORK TERM IFCE CONFIG PORT SELECTION Write security 3 Read security 5 Determines how the ATLAS 550 switchboard uses FXO ports for call routing The CIRCULAR method can be used for call load balancing among the available ports on the module Example The unit receives an incoming call on Port 3 The switchboard looks for an interface who...

Страница 288: ...r of ports ATLAS 550 uses for this endpoint DIAL PLAN FXO USER TERM IFCE CONFIG SIGNALING METHOD Write security 3 Read security 5 Defines to the ATLAS 550 the type of signaling DPT to be used across this trunk The signaling selected needs to match the signaling being provided by the network PSTN DPT mode operation configures the ATLAS 550to send DID digits out the USER TERM port toward the user eq...

Страница 289: ...ng with 9 9 and then with STRIP MSD set to 1 all digits would be sent toward the network except the leading 9 DIAL PLAN FXO USER TERM IFCE CONFIG SOURCE ID Write security 3 Read security 5 Simplifies the creation of a DIAL PLAN in applications where the criterion for switching calls to a certain endpoint is a function of which endpoint originated the call DEFAULT VALUE 0 The default ID for all end...

Страница 290: ... TERM IFCE CONFIG PORTS AVAILABLE Write security 3 Read security 5 Indicates which ports of the Quad Octal E M Option Modules have been defined in this switched endpoint indicated by in another switched endpoint indicated by s or in a DEDICATED MAP indicated by n This field is read only The following characters may display in this field NORMAL Always start with the lowest numbered available port i...

Страница 291: ...3 Read security 5 Defines the number of digits sent to ATLAS 550 from the network if DID is used This option only displays if DID is set to ENABLED DIAL PLAN E M USER TERM IFCE CONFIG CALLER ID NUMBER Write security 3 Read security 5 Defines the number the ATLAS 550 uses to provide caller ID to the network for outgoing calls sent through this endpoint This item is optional DIAL PLAN E M USER TERM ...

Страница 292: ...ong the available ports on the module Example The unit receives an incoming call on Port 3 The switchboard looks for an interface who has matching accept criteria to the number it received A match is found on interface Z that has PORT SELECTION set to ALIGNED This causes interface Z to only process the call if it has Port 3 available If all matching interfaces have PORT SELECTION set to ALIGNED an...

Страница 293: ... security 5 Specifies the number of V 35 ports ATLAS 550 uses for this endpoint DIAL PLAN V35NX USER TERM IFCE CONFIG NUMBER TO DIAL Write security 3 Read security 5 Specifies the number to dial on an outgoing call DIAL PLAN V35NX USER TERM IFCE CONFIG CALL TYPE Write security 3 Read security 5 Configures the call type either 56K or 64K used for outgoing calls from this endpoint DIAL PLAN V35NX US...

Страница 294: ...gn a unique SOURCE ID e g 7 to Port 1 of the module and then configure Port 2 to only accept calls from that unique SOURCE ID 7 DIAL PLAN V35NX USER TERM IFCE CONFIG MIN DS0 S Set this to 1 for typical single call connections Setting this greater than 1 will restrict connections to endpoints supporting aggregation e g BONDING of the specified number of DS0s DIAL PLAN V35NX USER TERM IFCE CONFIG MA...

Страница 295: ...ls VOICE for speech calls and AUDIO for 3 1kHz audio calls DIAL PLAN USSI USER TERM IFCE CONFIG SOURCE ID Write security 3 Read security 5 Simplifies the creation of a dial plan in applications where the criterion for switching calls to a certain endpoint is a function of which endpoint originated the call DEFAULT VALUE 0 Zero is the default ID for all endpoints and all accept numbers With default...

Страница 296: ...BRI S T Module acts like the network while interfacing to user equipment terminal adapters When you are working in the network termination section of the DIAL PLAN menu and SLT is defined as a S T BRI module the following interface configuration options are available DIAL PLAN S T BRI USER TERMINATION IFCE CONFIG SWITCH TYPE Write security 2 Read security 5 Defines the type of ISDN switch that the...

Страница 297: ...DIGITAL 56K DIAL PLAN PKT ENDPT USER TERM IFCE CONFIG REDIAL TIMER Write security 3 Read security 5 Selects the time delay in seconds between redial attempts SPID NUMBER Write security 3 Read security 5 Defines the SPID number s used for this BRI line Although the value of the SPID is not significant a SPID must be entered for each phone number For convenience the SPID can be set to be the same as...

Страница 298: ...umbers to accept Example An application requires that all calls that originate from Port 1 of the ATLAS 550 in Slot 1 be switched to Port 2 of that same module Assign a unique SOURCE ID e g 7 to Port 1 of the module and then configure Port 2 to only accept calls from that unique SOURCE ID 7 DIAL PLAN PKT ENDPT USER TERM IFCE CONFIG ROUTE INCOMING CALL Write security 3 Read security 5 Used to defin...

Страница 299: ...le only if GROUP is selected in the PORT PEP field Enter the expected calling part number in this field The ATLAS 550 will use the number entered here to compare to the number presented by the incoming call when configured to route based on Call Party Number DIAL PLAN PKT ENDPT USER TERM IFCE CONFIG MIN DS0 S Write security 3 Read security 5 Set this to 1 for typical single call connections A valu...

Страница 300: ...FIG SOURCE ID Write security 3 Read security 5 Simplifies the creation of a dial plan in applications where the criterion for switching calls to a certain endpoint is a function of which endpoint originated the call DEFAULT VALUE 0 Zero is the default ID for all endpoints and accept numbers With default values all calls are routed based only on the dialed number Multiple endpoints can have the sam...

Страница 301: ...RTUP DELAY Write security 3 Read security 5 The amount of time to wait after creating or changing the endpoint before allowing backup DIAL PLAN CKT BACKUP USER TERM IFCE CONFIG BACKUP DELAY Write security 3 Read security 5 The amount of time to delay after detecting an alarm before going into backup This only applies to originating endpoints If the circuit comes out of alarm before this time has e...

Страница 302: ...y applies to originating endpoints DIAL PLAN CKT BACKUP USER TERM IFCE CONFIG ENABLE SCHEDULE Write security 3 Read security 5 Use this menu to schedule the times when backup is enabled The following selections are available for the ENABLE SCHEDULE menu item DIAL PLAN CKT BACKUP USER TERM IFCE CONFIG TEST CALL Write security 3 Read security 5 This only applies to originating endpoints Use this men...

Страница 303: ... channels together DIAL PLAN PKT VOICE PACKET VOICE ENDPOINT DIAL PLAN PKT VOICE NETWORK TERM Write security 3 Read security 5 This menu allows the user to define option parameters for ports configured as network packet voice endpoints DIAL PLAN PKT VOICE NETWORK TERM IFCE CONFIG Write security 3 Read security 5 Specifies the configuration parameters for the endpoint DIAL PLAN PKT VOICE NETWORK TE...

Страница 304: ...M IFCE CONFIG SIGNALING METHOD Write security 3 Read security 5 Selects the type of signaling that the remote port is configured to expect Available options include E M IMMEDIATE E M WINK and LOOP START DIAL PLAN PKT VOICE NETWORK TERM IFCE CONFIG DIRECT INWARD DIALING Write security 3 Read security 5 Defines whether Direct Inward Dialing DID is used by the remote equipment If DID is enabled then ...

Страница 305: ...have the same SOURCE ID When creating the CALL ACCEPT list specify a SOURCE ID s as well as a dialed number or range of dialed numbers to accept DIAL PLAN PKT VOICE USER TERM Write security 3 Read security 5 This menu allows the user to define option parameters for ports configured as user packet voice endpoints DIAL PLAN PKT VOICE USER TERM IFCE CONFIG Write security 3 Read security 5 Specifies t...

Страница 306: ...ng and to decrease the total system bandwidth ENABLE this feature DIAL PLAN PKT VOICE USER TERM IFCE CONFIG SIGNALING METHOD Write security 3 Read security 5 Selects the type of signaling that the remote port is configured to expect Available options include the following E M IMMEDIATE E M WINK and LOOP START DIAL PLAN PKT VOICE USER TERM IFCE CONFIG DIRECT INWARD DIALING Write security 3 Read sec...

Страница 307: ...KT VOICE USER TERM IFCE CONFIG SOURCE ID Write security 3 Read security 5 Simplifies the creation of a dial plan in applications where the criterion for switching calls to a certain endpoint is a function of which endpoint originated the call DEFAULT VALUE 0 The default ID for all endpoints is 0 and all accept numbers is 0 With default values all calls are routed based only on the dialed number Mu...

Страница 308: ...Section 4 User Interface Guide ATLAS 550 System Manual 308 2004 ADTRAN Inc 61200305L2 1B ...

Страница 309: ...ty Levels 321 DLP 6 Updating the Firmware Using TFTP 323 DLP 7 Updating the Firmware Using XMODEM 327 DLP 8 Saving the Current Configuration Using TFTP 331 DLP 9 Loading a Configuration Using TFTP 333 DLP 10 Saving and Transferring a Current Configuration Using XMODEM 335 DLP 11 Loading a Configuration Using XMODEM 337 DLP 12 Connecting the ATLAS 550 to an External Modem 339 DLP 13 Using the ADTRA...

Страница 310: ...Section 5 Detail Level Procedures ATLAS 550 System Manual 310 2004 ADTRAN Inc 61200305L2 1B ...

Страница 311: ...r PC to the ATLAS 550 Prerequisite Procedures The ATLAS 550 must be powered up for terminal communication to function Tools and Materials Required A VT100 compatible terminal or PC with terminal emulation software An appropriate cable shipped with the unit to connect the ATLAS 550 to a terminal To prevent electrical shock do not install equipment in a wet location or during a lightning storm Elect...

Страница 312: ... it and use the serial port Using the CRAFT Port Plug the DB 9 male end of the data cable into the ATLAS 550 CRAFT Port on the front of the unit Make the connection to the VT100 terminal as appropriate for your equipment Using the ADMIN Port Plug the RJ 45 end of the data cable into the ATLAS 550 ADMIN port on the back of the unit Make the connection to the VT100 terminal as appropriate for your e...

Страница 313: ... ADMIN or CRAFT Port see To prevent electrical shock do not install equipment in a wet location or during a lightning storm Electronic equipment can be damaged by static electrical discharge Before handling it put on an antistatic discharge wrist strap to prevent damage to electronic components Place equipment in antistatic packing material when transporting or storing When working on equipment al...

Страница 314: ...n below 4 You are now logged in to the ATLAS menu system Perform the steps below in the order listed Because the ATLAS 550 grants users six levels of access you may not be able to use all of the menus check with your system administrator The lowest level of access Level 5 is read only and allows a user to see but not change the current configuration of the system The top level of access Level 0 is...

Страница 315: ...ted to an IP network and is powered up Please see your Network Administrator for the proper assignment of the following parameters IP ADDRESS SUBNET MASK and DEFAULT GATEWAY To prevent electrical shock do not install equipment in a wet location or during a lightning storm Electronic equipment can be damaged by static electrical discharge Before handling it put on an antistatic discharge wrist stra...

Страница 316: ...ddress 4 From the SYSTEM CONFIG ETHERNET menu select the SUBNET MASK option and press Enter Then enter the appropriate Subnet Mask 5 From the SYSTEM CONFIG ETHERNET menu select the DEFAULT GATEWAY option and press Enter Then enter the appropriate Default Gateway 6 Press the left arrow key to highlight the ETHERNET submenu This action saves your changes 7 Escape out to the SYSTEM CONFIG menu and lo...

Страница 317: ...ovisioning tasks detailed in DLP 3 Setting IP Parameters for the ATLAS 550 should be complete Tools and Materials Required Access to a PC or other computer connected to the LAN To prevent electrical shock do not install equipment in a wet location or during a lightning storm Electronic equipment can be damaged by static electrical discharge Before handling it put on an antistatic discharge wrist s...

Страница 318: ...nse light for each port verify that the carrier sense light for the port to which the ATLAS 550 is connected is lit If this light is not lit check the cabling between the hub and the shelf The connection may also be verified using the ETHERNET LED located on the front panel of the ATLAS 550 Verify the IP Address Subnet Mask and Default Gateway on the remote computer system If none of these steps a...

Страница 319: ...et session is established press CTRL L to logout and close the session Refer to the documentation of the computer system if you are unsure how to perform a Telnet Most computers running a networked version of Microsoft Windows or UNIX allow a Telnet to be performed by typing telnet IP Address at a command line prompt Telnet is a utility common on many local area networks that allows remote access ...

Страница 320: ...Section 5 DLP 4 ATLAS 550 System Manual 320 2004 ADTRAN Inc 61200305L2 1B ...

Страница 321: ...erent passwords This DLP describes the steps which must be performed to add or remove user profiles and to assign password security levels in the ATLAS 550 Tools and Materials Required VT100 terminal or PC with VT100 terminal emulation software To prevent electrical shock do not install equipment in a wet location or during a lightning storm Electronic equipment can be damaged by static electrical...

Страница 322: ...y select the first column 0 and pressing I for insert 5 Give the new user profile a name by selecting the LABEL field pressing Enter and typing the user defined name 6 Personalize the password for the appropriate label by selecting the PASSWORD field pressing Enter and then typing the appropriate password 7 Determine the password level for the corresponding label The ATLAS 550 contains six differe...

Страница 323: ...ng XMODEM Tools and Materials Required A PC with Telnet client software A TFTP server accessible on the local network A TFTP server is provided with the unit as part of the ADTRAN Utilities software To prevent electrical shock do not install equipment in a wet location or during a lightning storm Electronic equipment can be damaged by static electrical discharge Before handling it put on an antist...

Страница 324: ...t option enter the time in 24 hour format such as 23 00 00 for 11 00 pm Enter the date in mm dd yyyy format for example 06 30 2004 9 Select VIEW CURRENT UPDATE STATUS to verify the progress of the current firmware update or to identify any errors encountered during the download Refer to the table on the following page for a detailed description of messages found in this field 10 Select BEGIN FIRMW...

Страница 325: ... successfully completed IDLE displays in the CURRENT UPDATE STATUS field and MODULE UPDATE COMPLETE displays in the PREVIOUS UPDATE STATUS field The ATLAS 550 will either restart immediately and resume operation or will restart at the specified time and day of the week depending on your selection ...

Страница 326: ...Section 5 DLP 6 ATLAS 550 System Manual 326 2004 ADTRAN Inc 61200305L2 1B ...

Страница 327: ...he Firmware Using TFTP for instructions on using TFTP Tools and Materials Required VT100 terminal or PC with VT100 terminal emulation software XMODEM software To prevent electrical shock do not install equipment in a wet location or during a lightning storm Electronic equipment can be damaged by static electrical discharge Before handling it put on an antistatic discharge wrist strap to prevent da...

Страница 328: ...ield To use that option enter the time in 24 hour format such as 23 00 00 for 11 00 pm Enter the date in mm dd yyyy format for example 09 30 2000 7 View CURRENT UPDATE STATUS to verify the progress of the current firmware update or to identify any errors encountered during the download 8 Select BEGIN FIRMWARE UPDATE to start the update Enter Y to confirm the transfer and set up the module to recei...

Страница 329: ...on or restart at the specified time and day of the week depending on your selection Alternatively if the unit is part of a management cluster connected to the local network you may use a PC connected to the network to Telnet into the unit By using the ETHERNET port the ATLAS 550 may be quickly upgraded using TFTP provided there is a TFTP server on the local network The ATLAS 550 ships with ADTRAN ...

Страница 330: ...Section 5 DLP 7 ATLAS 550 System Manual 330 2004 ADTRAN Inc 61200305L2 1B ...

Страница 331: ...client software A TFTP server accessible on the local network A TFTP server is provided with the unit as part of the ADTRAN Utilities software To prevent electrical shock do not install equipment in a wet location or during a lightning storm Electronic equipment can be damaged by static electrical discharge Before handling it put on an antistatic discharge wrist strap to prevent damage to electron...

Страница 332: ...rain the format of the filename depending on the operating system of the server For example a TFTP server running on a PC under Windows 3 1 may only permit 8 3 format filenames 8 characters period and three extension characters 6 Select the SAVE CONFIG REMOTELY menu field and press Enter Respond with Y to confirm request 7 View CURRENT TRANSFER STATUS to verify the progress of the current transfer...

Страница 333: ...re A TFTP server accessible on the local network A TFTP server is provided with the unit as part of the ADTRAN Utilities software To prevent electrical shock do not install equipment in a wet location or during a lightning storm Electronic equipment can be damaged by static electrical discharge Before handling it put on an antistatic discharge wrist strap to prevent damage to electronic components...

Страница 334: ...stem of the server For example a TFTP server running on a PC under Windows 3 1 may only permit 8 3 format filenames 8 characters period and three extension characters 6 Select the LOAD AND USE CONFIG menu field and press Enter Respond with Y to confirm request 7 View CURRENT TRANSFER STATUS to verify the progress of the current upload 8 When the upload has successfully completed IDLE displays in t...

Страница 335: ...ort and XMODEM Tools and Materials Required VT100 terminal or PC with VT100 terminal emulation software XMODEM software To prevent electrical shock do not install equipment in a wet location or during a lightning storm Electronic equipment can be damaged by static electrical discharge Before handling it put on an antistatic discharge wrist strap to prevent damage to electronic components Place equ...

Страница 336: ...tion 6 Configure the VT100 terminal or terminal emulation software to RECEIVE and prompt for a filename 7 View the CURRENT TRANSFER STATUS to verify the progress of the current transfer 8 From the terminal emulation software begin the XMODEM transfer by using the appropriate command sequence For Windows HyperTerminal select TRANSFER RECEIVE FILE Enter the filename including path and select XMODEM ...

Страница 337: ...Tools and Materials Required VT100 terminal or PC with VT100 terminal emulation software XMODEM software To prevent electrical shock do not install equipment in a wet location or during a lightning storm Electronic equipment can be damaged by static electrical discharge Before handling it put on an antistatic discharge wrist strap to prevent damage to electronic components Place equipment in antis...

Страница 338: ...f this does not appear please review the preceding steps above for possible configuration errors 6 From the terminal emulation software begin the XMODEM transfer by using the appropriate command sequence For Windows HyperTerminal select TRANSFER SEND FILE Enter the filename including path and select XMODEM as the transfer method ATLAS 550 configuration files should have a cfg extension If necessar...

Страница 339: ... external modem Tools and Materials Required Female RJ 45 to Male DB 25 Connector shipped with unit Modem Modem Cable To prevent electrical shock do not install equipment in a wet location or during a lightning storm Electronic equipment can be damaged by static electrical discharge Before handling it put on an antistatic discharge wrist strap to prevent damage to electronic components Place equip...

Страница 340: ...iled instructions 9 From the MAIN MENU select the SYSTEM CONFIG menu and press the right arrow key to enter the right pane menus 10 From the SYSTEM CONFIG menu select the CHAIN PORT menu and press Enter Once in the CHAIN PORT menus press the right arrow key to enter the right pane menus 11 From the CHAIN PORT menus select the PORT TYPE menu and select DIAL Perform the following steps in the order ...

Страница 341: ...ot lost The ATLAS 550 ships with an ADTRAN provided Syslog server Prerequisite Procedures This procedure assumes that the ATLAS 550 unit is connected to an IP network and is powered up Tools and Materials Required Syslog server provided on ATLAS 550 System CD in ADTRAN Utilities To prevent electrical shock do not install equipment in a wet location or during a lightning storm Electronic equipment ...

Страница 342: ...OGRAMS ADTRAN UTILITIES SYSLOG When the Syslog window opens you will see LOCAL0 through LOCAL7 listed on the left This should correspond with the HOST FACILITY specified in the ATLAS 550 The Syslog program must be open on your PC in order for it to record ATLAS 550 information The Syslog files can be viewed through the Syslog window and they are also available under the ADTRAN Utilities Folder nam...

Страница 343: ...IT LOG button on the left side of the Syslog screen Only the SOURCE options that are selected with an x will be displayed in the Syslog file In this example all options are displayed Under the LOG FILES menu option the user may erase log files define Red events set priorities and clear Red events The ERASE LOG FILES option erases the specified text log file DEFINE RED EVENTS allows the user to pre...

Страница 344: ...ges to be logged to an ASCII text file Mark the lowest priority Event Log message you want to log to the Syslog server text file For example the figure below shows that all messages will be logged to the text file The HELP menu also explains these features Click on HELP CONTENTS SYSLOG HOST DAEMON for further explanation of Syslog features ...

Страница 345: ...slot screwdriver 22 or 24 AWG 2 conductor twisted pair cross connect wire To prevent electrical shock do not install equipment in a wet location or during a lightning storm Electronic equipment can be damaged by static electrical discharge Before handling it put on an antistatic discharge wrist strap to prevent damage to electronic components Place equipment in antistatic packing material when tra...

Страница 346: ...er the first slot or the second slot for the NC or NO connections respectively 8 Optional If you wish to have the ATLAS 550 monitor for external alarms insert one strand of wire into the first slot counted from the left for the Alarm Out signal of the 2 position terminal block RELAY Insert the other strand into the last slot for the Alarm In signal 9 Connect the wires to the appropriate terminals ...

Страница 347: ...00305L2 1B 2004 ADTRAN Inc 347 Table 2 External Relay Monitor Connector Pinout Pin Name Description 1 Alarm Out Outputs EIA 232 level signal for connection to external alarm contacts 2 Alarm In Monitors signal coming from external alarm contacts ...

Страница 348: ...Section 5 DLP 14 ATLAS 550 System Manual 348 2004 ADTRAN Inc 61200305L2 1B ...

Страница 349: ...Procedures Before beginning this procedure the ATLAS 550 should be mounted in its permanent location and the alarm contacts should be connected see DLP 14 Connecting the Alarm Contacts Tools and Materials Required VT100 terminal or PC with VT100 terminal emulation software To prevent electrical shock do not install equipment in a wet location or during a lightning storm Electronic equipment can be...

Страница 350: ...riate threshold level The ALARM RELAY will set for this threshold and all other alarms of greater importance Refer to Section 7 System Event Logging of this user manual for a listing of all alarms and levels of importance 1 Go to the SYSTEM CONFIG menu and press the right arrow key to access the right pane menus Then select the EVENT LOGGING menu and press Enter Once in the EVENT LOGGING menu pres...

Страница 351: ...61200305L2 1B 2004 ADTRAN Inc 351 CONFIGURATION GUIDES CFG 1 Dial Backup for Dedicated T1 Circuits 353 ...

Страница 352: ...Section 6 Configuration Guides ATLAS 550 System Manual 352 2004 ADTRAN Inc 61200305L2 1B ...

Страница 353: ...is application requires an ATLAS 550 containing firmware B 01 or later a V 35 Nx Module P N 1200311L1 and a BONDing Module P N 1200326L1 if bonding of B channels is required Description The ATLAS 550 will either originate or answer a dial backup call upon detection of a network failure or data failure on the T1 E1 A network failure is any physical layer T1 E1 failure such as red alarm or loss of s...

Страница 354: ...TED MAPS menu field Once the DEDICATED MAPS menu is selected press the right arrow key to move to the right pane menu items then select the CREATE EDIT MAPS field and press Enter To configure this sample network perform the following steps in the order listed Configure the Dedicated T1 Data Link ATLAS 550 2 1 0 1 0 2 T1 PRI Router TSU 120 ISU 128 BRI LDN1 555 2000 LDN2 555 2001 SPID1 770 555 2000 ...

Страница 355: ...nter the slot location of the V 35 module that will connect to the Host side router by selecting the FROM SLT column Press Enter to display a list of available slots For this sample network choose S2 V35NX 2 5 Enter the port location of the V 35 port that connects to the Host side router by selecting the PORT column Press Enter to display a list of available ports For this sample network choose 1 ...

Страница 356: ...r this sample network choose N1 T1 PRI 1 7 Enter the port location of the T1 port that connects to the network T1 circuit by selecting the PORT column Press Enter to display a list of available ports For this sample network choose 1 T1 PRI 8 Since a Network Module T1 PRI port was selected the system automatically populates the FROM CONFIG field with RATE 64K For option module T1 PRI interfaces you...

Страница 357: ...TION field press Enter and then enter 1 18 1 From the main menu select the DIAL PLAN menu field Press the right arrow key to move to the right pane menu items then select the NETWORK TERM field and press Enter 2 Enter the slot location of the network PRI being used for Dial Backup by selecting the SLOT SVC field Press Enter to display a list of available slots For this sample network choose S1 T1 ...

Страница 358: ...tion of the network PRI being used for Dial Backup by selecting the PORT PEP column to display a list of available ports For this sample network choose 1 T1 PRI 4 Select the SIG field and press Enter to display a list of available signaling methods For this sample network choose the PRI selection ...

Страница 359: ... of the PRI D channel by selecting the IFCE CONFIG field and pressing Enter Once at the IFCE CONFIG menus configure the switch type by selecting the SWITCH TYPE field and choosing the appropriate protocol Remember this is the protocol running on the Central Office switch not the manufacturer s name For this sample network choose the NATIONAL ISDN selection For a detailed explanation of possible en...

Страница 360: ... field Press the right arrow key to move to the right pane menu items then select the USER TERM field and press Enter 2 For the slot location of the backup entry select the SLOT SVC field and press Enter to display a list of available slots For this sample network choose CIRCUIT BACKUP Configure the Dial Backup Endpoint ...

Страница 361: ... 64 PORT 4 Enter the correct call routing information for this backup entry by selecting the IN ACCEPT field and pressing Enter Then press the right arrow key to enter the right pane menus Select the ACCEPT NUMBER field and press Enter To accept calls coming from the network PRI enter 555 1000 The PORT PEP field will only allow you to select V 35 ports that were entered in the FROM SLT field in th...

Страница 362: ...ediately go into backup OUTGOING CALL TYPE DIGITAL 56K Data rate for the backup endpoint is set to 56kbps DIGITAL 64K Data rate for the backup endpoint is set to 64kbps SOURCE ID The SOURCE ID should remain in the default state unless it has been assigned elsewhere in the configuration Please refer to the User Interface Guide beginning on page 63 for a detailed discussion of the SOURCE ID field OU...

Страница 363: ...h of time in seconds that determines how long the T1 must be in a fail state before dial backup will take affect RESTORE DELAY Length of time in seconds that determines how long the main circuit must be restored before dial backup will switch off MAX NUMBER OF RETRIES Options are NONE 3 10 and UNLIMITED This is the number of times the ATLAS 550 will redial if first DBU connection fails REDIAL TIME...

Страница 364: ...Section 6 CFG 1 ATLAS 550 System Manual 364 2004 ADTRAN Inc 61200305L2 1B ...

Страница 365: ...ies 376 TABLES Table 1 System Controller Events 369 Table 2 Switchboard Events 370 Table 3 Nx 56 64 Events 370 Table 4 T1 Events 371 Table 5 Ethernet Events 372 Table 6 ISDN Events 372 Table 7 Circuit Backup Events 373 Table 8 DP Outgoing Signaling Events 374 Table 9 Modem Management Module Events 374 Table 10 ISDN Cause Code Events 375 Table 11 Cause Code Log Entry Location Designations 376 Table...

Страница 366: ... the event CATEGORY thresholds for the Event Log 1 From the main menu go to the SYSTEM CONFIG menu and press the right arrow key to enter the right pane menus 2 Select the EVENT LOGGING field and press Enter Once in the EVENT LOGGING menus press the right arrow key to access the right pane menus 3 Refer to the tables in this section to determine the desired CATEGORY thresholds ...

Страница 367: ...VENTS The following steps outline the procedure for viewing EVENT LOG messages 1 From the MAIN MENU go to the SYSTEM STATUS menu and press the right arrow key to enter the right pane menus Use caution when changing CATEGORY values from their default levels If too many sources have their CATEGORY values set too low the number of messages being logged in a given period can be very large If too many ...

Страница 368: ...e EVENT LOG press the right arrow key to access the actual messages The EVENT LOG messages are stored in a first in first out table Therefore the most recent log entry is found at the top of the log EVENT LOG messages may be sent to an external Syslog server for storage Refer to DLP 13 Using the ADTRAN Utility Syslog Event Log for more details ...

Страница 369: ...CO switch pressed Cold NORMAL System cold start a a Generated five seconds after the completion of system initialization External Alarm Cleared MINOR External alarm cleared External Alarm Detected MINOR Alarm detected on External Alarm Monitor Firmware invalid CRITICAL Corrupted firmware Firmware update completed INFO Flash download successful Firmware update failed CRITICAL Flash download failed ...

Страница 370: ...ack Activated Nx 56 64 Bilateral Loopback Cleared WARNING Bilateral Loopback Deactivated Nx 56 64 Clock Slip Alarm Active MAJOR Clock Slip Alarm Active Nx 56 64 Clock Slip Alarm Cleared MAJOR Clock Slip Alarm Cleared Nx 56 64 CTS Asserted INFO CTS Asserted Nx 56 64 CTS Dropped INFO CTS Dropped Nx 56 64 DCD Asserted INFO DCD Asserted Nx 56 64 DCD Dropped INFO DCD Dropped Nx 56 64 DTR Asserted INFO ...

Страница 371: ...e Loopback Active T1 Loopback Cleared WARNING Loopback Cleared T1 LOS Active MAJOR LOS Alarm Set T1 LOS Cleared MAJOR LOS Alarm Cleared T1 Payload Loopback Active WARNING Payload Loopback Active T1 Red Alarm Active MAJOR Red Alarm Set T1 Red Alarm Cleared MAJOR Red Alarm Cleared T1 Tot ES Thrs Exceeded WARNING Total T1 Errored Seconds Threshold Exceeded T1 Total CSS Thrs Exceeded WARNING Total T1 ...

Страница 372: ...spid was rejected MAJOR SPID Failed BRI NT SPID Negotiations failed resetting the link MAJOR SPID Negotiation failed BRI NT SPID Negotiations failed Retrying MINOR SPID Retry in progress Call not accepted to called number No channel available INFO Call not accepted Call to called number cleared from ATLAS end INFO Call cleared Call to called number connected INFO Call connected Call to called numb...

Страница 373: ... Table 7 Circuit Backup Events Console Log String Category Event Attempting Circuit Backup MINOR Circuit Backup call attempted to restore data circuit Circuit Backup Active MINOR Port is currently in backup Circuit Backup Attempt Failed MAJOR Outgoing backup call was unsuccessful Circuit Backup Data Alarm Active MINOR Inband keep alive messages were disrupted or corrupted Circuit Backup Data Alarm...

Страница 374: ...le if AB signal bits are 01 then the total signal bits would be 01 01 Putting that in hexadecimal notation results in an event of Tx set Rx ABCD 0x 05 INFO ATLAS changed signal bits on port RX Change Rx ABCD Tx ABCD INFO Equipment connected to port changed signal bits Table 9 Modem Management Module Events Console Log String Category Event Modem Management Call Answered INFO Incoming call was succ...

Страница 375: ...8 CALL_REJECTED INFO 21 CAP_NOT_IMPLEMENTED MINOR 65 CHAN_NOT_IMPLEMENTED MINOR 66 CHANNEL_UNACCEPTABLE INFO 6 DEST_OUT_OF_ORDER INFO 27 FACILITY_NOT_IMPLEMENTED MAJOR 69 FACILITY_NOT_SUBSCRIBED MINOR 50 FACILITY_REJECTED INFO 29 INCOMING_CALL_BARRED MINOR 54 INCOMPATIBLE_DEST MAJOR 88 INTERWORKING_UNSPEC MAJOR 127 INVALID_CALL_REF MAJOR 81 INVALID_ELEM_CONTENTS MAJOR 100 INVALID_MSG_UNSPEC MAJOR ...

Страница 376: ...ts PRE_EMPTED WARNING 45 PROTOCOL_ERROR MAJOR 111 REQ_CHANNEL_NOT_AVAIL WARNING 44 RESP_TO_STAT_ENQ INFO 30 SERVICE_NOT_AVAIL MINOR 63 TEMPORARY_FAILURE WARNING 41 TIMER_EXPIRY MAJOR 102 UNASSIGNED_NUMBER INFO 1 UNSPECIFIED_CAUSE INFO 31 USER_BUSY INFO 17 WRONG_MESSAGE INFO 98 WRONG_MSG_FOR_STATE MAJOR 101 Table 11 Cause Code Log Entry Location Designations Code Location INTL International network...

Страница 377: ...x dump of the entire LAPD frame Table 13 ISDN Call Control Messages Console Log String Category Event Host CC tag call ID message INFO ISDN Call Control Messages CC Host tag call ID message INFO ISDN Call Control Messages Table 14 Source ISDN Information Elements Console Log String Category Event message contents INFO ISDN Information Element a a Provides a hex dump of the ISDN IE sent with a call...

Страница 378: ...Section 7 System Event Logging ATLAS 550 System Manual 378 2004 ADTRAN Inc 61200305L2 1B ...

Страница 379: ...rosoft Windows 3 1 or higher The following sections describe the Syslog Telnet VT100 and TFTP Server utilities CONTENTS Telnet Utility 380 Session Menu 381 Edit Menu 382 Options Menu 382 Capture Menu 382 Help Menu 383 VT100 Utility 383 Session Menu 384 Edit Menu 384 Port Menu 384 Options Menu 384 Capture Menu 385 Help Menu 385 TFTP Server 385 Server Menu 386 Print Log 386 Help 387 Status Field 387...

Страница 380: ...us in the User Interface Guide section of this manual The Telnet menus include SESSION EDIT OPTIONS CAPTURE and HELP see the menu tree in Figure 1 Figure 1 Telnet Menu Tree Host Name Connect Port Session Disconnect Edit Entry Transfer Cfg Add New Exit Delete Connect Edit Copy Paste Background Telnet Options Colors Bold Local Echo Text Auto Repeat File Start Cfg Capture Stop Cfg Capture Capture Buf...

Страница 381: ... to display the following options Edit Entry Changes either the unit name or the IP address of each host Press either Tab Return or a period after each number in the IP address to move to the next field If you press Return or enter a period while the cursor is located in an IP field that field entry is deleted Add New Prompts you for the same information as the EDIT ENTRY dialog box for new host W...

Страница 382: ...Repeat Repeats characters you select from the keyboard if you hold down the key Capture Menu Provides options for capturing screen images File Sends screen options data to a file in the format options listed below Start Cfg Capture Used with the ADTRAN product line to start sending the scrolling screen capture to a file storage location Stop Cfg Capture Used with the ADTRAN product line to stop se...

Страница 383: ...erminal menu refer to Navigating the Terminal Menus in the User Interface Guide section of this manual If you need help setting up the ATLAS 550 for a VT100 session refer to DLP 1 Connecting a VT100 Terminal or PC to the ADMIN or CRAFT Port VT100 menus include SESSION EDIT PORT OPTIONS CAPTURE and HELP see the menu tree in Figure 2 Figure 2 VT100 Menu Tree Connect Session Disconnect File Transfer ...

Страница 384: ...the Telnet EDIT MENU see Edit Menu on page 382 Port Menu Changes serial COM port SETTINGS Provides data rate settings from 300 57600 bps Options Menu Provides terminal screen commands Refresh Screen Redraws the screen Connect Provides the options TRANSMIT WAKEUP and TRANSMIT REFRESH Transmit Wakeup Provides a control sequence that puts the ATLAS 550 Control Port online in terminal mode Transmit Re...

Страница 385: ...backup file The saved file may also be used to send the same configuration to multiple ATLAS 550 units Transfer configuration files using the TFTP protocol a TCP IP user protocol via the Ethernet port The ATLAS 550 must have a valid IP address subnet mask and default gateway if required and be connected to an Ethernet network before proceeding Figure 4 shows the TFTP server interface For informati...

Страница 386: ... Enable Enables the TFTP server The IP address displays in the Status field and Server Ready displays in the Log field Disable Disables the TFTP server When you select this option the message Port Closed displays in the STATUS field and in the LOG field Abort Terminates a transfer that is in progress Exit Terminates active transfers and closes the TFTP window Print Log Provides print options to Cl...

Страница 387: ... field in the center of the screen displays prompts about the status of active transfers such as bytes transferred and received 5 METER FIELD The XMIT meter provides a visual record of the transfer progress 6 LOG FIELD This field displays a record of all of the events that occur during the time the TFTP Server is enabled Use the scroll bar to move up and down the list To clear the information in t...

Страница 388: ...Section 8 ADTRAN Utilities ATLAS 550 System Manual 388 2004 ADTRAN Inc 61200305L2 1B ...

Страница 389: ...2 1 10 18 DS1 397 Table 6 rfc 1315 mib 1 3 6 1 2 1 10 32 Frame Relay 399 Table 7 adtran mib 1 3 6 1 4 1 664 ADTRAN 400 Table 8 ads1 mib 1 3 6 1 4 1 664 2 3 400 Table 9 atunit mib 1 3 6 1 4 1 664 2 154 1 5 adATLASUnitmg 401 Table 10 atmod mib 1 3 6 1 4 1 664 2 154 1 6 adATLASModulemg 402 Table 11 atvoice mib 1 3 6 1 4 1 664 2 154 1 10 adATLASVoicemg 403 Table 12 atv35nx mib 1 3 6 1 4 1 664 2 154 1 ...

Страница 390: ...me Relay DTEs adtran mib Adtran ads1 mib Adtran fperform mib Adtran atproduc mib Atlas atunit mib Atlas Unit atmod mib Atlas Module atv35nx mib Atlas Interface atbri mib Atlas Interface att1 mib Atlas Interface atvoice mib Atlas Interface athssv35 mib Atlas Interface at550 mib Atlas Product Specific Atlas 550 atqbriu mib Atlas Product Specific Quad BRI U Option Module You also need RFC1155 SMI RFC...

Страница 391: ...essary RFC1158 MIB if necessary RFC 1212 if necessary RFC 1215 if necessary rfc1213 mib rfc1406 mib rfc1315 mib adtran mib ads1 mib fperform mib atproduc mib atunit mib atmod mib atv35nx mib atbri mib att1 mib atvoice mib athssv35 mib at550 mib atqbriu mib Table 3 Traps Supported by the ATLAS 550 Trap Description rfc1215 mib coldStart warmStart linkDown linkUp authenticationFailure rfc1315 mib frD...

Страница 392: ...400703 adATLASV35NxZeroAlarmActive 15400704 adATLASV35NxZeroAlarmInActive 15400705 adATLASV35NxExtClkAlarmActive 15400706 adATLASV35NxExtClkAlarmInActive 15400707 adATLASV35NxRTSActive 15400708 adATLASV35NxRTSInActive 15400709 adATLASV35NxCTSActive 15400710 adATLASV35NxCTSInActive 15400711 adATLASV35NxDTRActive 15400712 adATLASV35NxDTRInActive 15400713 adATLASV35NxDSRActive 15400714 adATLASV35NxDS...

Страница 393: ...ellowInActive 15400911 adATLAST1CurrentES 15400912 adATLAST1CurrentSES 15400913 adATLAST1CurrentSEFS 15400914 adATLAST1CurrentUAS 15400915 adATLAST1CurrentCSS 15400916 adATLAST1CurrentPCV 15400917 adATLAST1CurrentLES 15400918 adATLAST1CurrentLCV 15400919 adATLAST1TotalES 15400920 adATLAST1TotalSES 15400921 adATLAST1TotalUAS 15400923 adATLAST1TotalCSS 15400924 adATLAST1TotalPCV 15400925 adATLAST1To...

Страница 394: ...yString RW sysName DisplayString RW sysLocation DisplayString RW sysServices Integer RO interfaces ifNumber Integer RO ifTable ifEntry ifIndex Integer RO ifDescr DisplayString RO ifType Integer RO ifSpeed Gauge RO ifPhysAddress PhysAddress RO ifAdminStatus Integer RW ifOperStatus Integer RO ip ipForwarding Integer RW ipDefaultTTL Integer RW ipInReceives Counter RO ipInHdrErrors Counter RO ipInAddr...

Страница 395: ...r RO icmp icmpInMsgs Counter RO icmpInErrors Counter RO icmpInDestUnreachs Counter RO icmpInTimeExcds Counter RO icmpInParmProbs Counter RO icmpInSrcQuenchs Counter RO icmpInRedirects Counter RO icmpInEchos Counter RO icmpInEchoReps Counter RO icmpInTimestamps Counter RO icmpInTimestampReps Counter RO icmpInAddrMasks Counter RO icmpInAddrMaskReps Counter RO icmpOutMsgs Counter RO icmpOutErrors Cou...

Страница 396: ...Counter RO tcpEstabResets Counter RO tcpCurrEstab Gauge RO tcpInSegs Counter RO tcpOutSegs Counter RO tcpRetransSegs Counter RO tcpConnTable tcpConnEntry tcpConnState Integer RW tcpConnLocalAddress IpAddress RO tcpConnLocalPort Integer RO tcpConnRemAddress IpAddress RO tcpConnRemPort Integer RO tcpInErrs Counter RO tcpOutRsts Counter RO udp udpInDatagrams Counter RO udpNoPorts Counter RO udpInErro...

Страница 397: ...unter RO snmpInGetNexts Counter RO snmpInSetRequests Counter RO snmpInGetResponses Counter RO snmpInTraps Counter RO snmpOutTooBigs Counter RO snmpOutNoSuchNames Counter RO snmpOutBadValues Counter RO snmpOutGenErrs Counter RO snmpOutGetRequests Counter RO snmpOutGetNexts Counter RO snmpOutSetRequests Counter RO snmpOutGetResponses Counter RO snmpOutTraps Counter RO snmpEnableAuthenTraps Counter R...

Страница 398: ...rentPCVs Gauge RO dsx1CurrentLESs Gauge RO dsx1CurrentBESs Gauge RO dsx1CurrentLCVs Gauge RO dsx1IntervalTable dsx1IntervalEntry dsx1IntervalIndex Integer RO dsx1IntervalNumber Integer RO dsx1IntervalESs Gauge RO dsx1IntervalSESs Gauge RO dsx1IntervalSEFSs Gauge RO dsx1IntervalUASs Gauge RO dsx1IntervalCSSs Gauge RO dsx1IntervalPCVs Gauge RO dsx1IntervalLESs Gauge RO dsx1IntervalBESs Gauge RO dsx1...

Страница 399: ...Interval Integer RW frDlcmiFullEnquiryInterval Integer RW frDlcmiErrorThreshold Integer RW frDlcmiMonitoredEvents Integer RW frDlcmiMaxSupportedVCs Integer RW frDlcmiMulticast Integer RW frCircuitTable frCircuitEntry frCircuitIfIndex Integer RO frCircuitDlci Integer RO frCircuitState Integer RW frCircuitReceivedFECNs Counter RO frCircuitReceivedBECNs Counter RO frCircuitSentFrames Counter RO frCir...

Страница 400: ...mber DisplayString RO adProdRevision DisplayString RO adProdSwVersion DisplayString RO adProdPhysAddress PhysAddress RO adMgmt adAdmin adPerform adShared adIdentity adConformance Table 8 ads1 mib 1 3 6 1 4 1 664 2 3 adDS1AlarmTable adDS1AlarmEntry adDS1AlarmIndex Integer RO adDS1AlarmEnable Integer RW adDS1LineEvent Integer RO adDS1LineArm Integer RW adDS1AlertTable adDS1AlertEntry adDS1AlertIndex...

Страница 401: ...otalThrsSES Integer RW adDS1TotalThrsSEFS Integer RW adDS1TotalThrsSEFS Integer RW adDS1TotalThrsCSS Integer RW adDS1TotalThrsPCVsf Integer RW adDS1TotalThrsPCVesf Integer RW adDS1TotalThrsLES Integer RW adDS1TotalThrsLCV Integer RW Table 9 atunit mib 1 3 6 1 4 1 664 2 154 1 5 adATLASUnitmg adATLASUnitmg adATLASUnitInfo adATLASUnitIfNumber Integer RO adATLASUnitPortInfoTable adATLASUnitPortInfoEnt...

Страница 402: ...SConfigXferDwnldControl Integer RW adATLASConfigXferUpldControl Integer RW adATLASUnitStatus adATLASUnitFPStatus Integer RO Table 10 atmod mib 1 3 6 1 4 1 664 2 154 1 6 adATLASModulemg adATLASModulemg adATLASModuleInfoNumber Integer RO adATLASModuleInfoTable adATLASModuleInfoEntry adATLASModuleInfoIndex Integer RO adATLASModuleInfoNumIfs Integer RO adATLASModuleInfoNumRsrcs Integer RO adATLASModul...

Страница 403: ...r RW adATLASVoiceTst1kHzTone Integer RW adATLASVoiceTstLpBk Integer RW Table 12 atv35nx mib 1 3 6 1 4 1 664 2 154 1 7 adATLASV35Nxmg adATLASV35Nxmg adATLASV35NxIfNumber Integer RO adATLASV35NxIfTable adATLASV35NxIfEntry adATLASV35NxIfIndex Integer RO adATLASV35NxIfSlotNum Integer RO adATLASV35NxIfPortNum Integer RO adATLASV35NxIfAlarmStatus Integer RO adATLASV35NxIfDTEStatus Integer RO adATLASV35N...

Страница 404: ...3 atbri mib 1 3 6 1 4 1 664 2 154 1 8 adATLASBRImg adATLASBRImg adATLASBRIIfNumber Integer RO adATLASBRIIfTable adATLASBRIIfEntry adATLASBRIIfIndex Integer RO adATLASBRIIfSlotNum Integer RO adATLASBRIIfPortNum Integer RO adATLASBRIIfAlarmStatus Integer RO adATLASBRIIfChanStatTable adATLASBRIIfChanStatEntry adATLASBRIIfChanStatIndex Integer RO adATLASBRIIfChanStatB1 Integer RO adATLASBRIIfChanStatB...

Страница 405: ...valLOFC Gauge RO adATLAST1IfDS0Table adATLAST1IfDS0Entry adATLAST1IfDS0Index Integer RO adATLAST1IfDS0Status Octet String RO adATLAST1IfDS0Alarm Octet String RO adATLAST1IfDS0RxSignalStatusA Octet String RO adATLAST1IfDS0RxSignalStatusB Octet String RO adATLAST1IfDS0TxSignalStatusA Octet String RO adATLAST1IfDS0TxSignalStatusB Octet String RO adATLAST1TstTable adATLAST1TstEntry adATLAST1TstIndex I...

Страница 406: ...O adATLAS550FpnlNwTest Integer RO adATLAS550FpnlNwError Integer RO adATLAS550FpnlNwAlarm Integer RO adATLAS550FpnlModLeds adATLAS550FpnlModNumber Integer RO adATLAS550FpnlMLTable adATLAS550FpnlMLEntry adATLAS550FpnlMLIndex Integer RO adATLAS550FpnlMLStatus Integer RO adATLAS550FpnlMLOnline Integer RO adATLAS550FpnlMLTest Integer RO Table 16 atqbriu mib 1 3 6 1 4 1 664 2 274 adATLAS550QuadBRIUmg ad...

Страница 407: ... Integer RO adFRPerformIntPvcSlotIndex Integer RO adFRPerformIntPVCStateChange Counter RO adFRPerformIntPVCInactiveTime Counter RO adFRPerformIntPVCFramesRx Counter RO adFRPerformIntPVCFramesTx Counter RO adFRPerformIntPVCBytesRx Counter RO adFRPerformIntPVCBytesTx Counter RO adFRPerformIntPVCAvgThruputTx Gauge RO adFRPerformIntPVCAvgThruputRx Gauge RO adFRPerformIntPVCMaxThruputTx Counter RO adFR...

Страница 408: ...able adFRPerformIntPortStatusEntry adFRPerformIntIfIndex Integer RO adFRPerformIntPortSlotIndex Integer RO adFRPerformIntPortFramesRx Counter RO adFRPerformIntPortFramesTx Counter RO adFRPerformIntPortBytesRx Counter RO adFRPerformIntPortBytesTx Counter RO adFRPerformIntPortAvgThruputTx Gauge RO adFRPerformIntPortAvgThruputRx Gauge RO adFRPerformIntPortMaxThruputTx Counter RO adFRPerformIntPortMax...

Страница 409: ...dFRPerformIntSignalErrors Counter RO adFRPerformIntSignalTimeOut Counter RO adFRPerformIntSignalStateChange Counter RO adFRPerformIntHistoryTime adFRPerformIntHistoryTimeTable adFRPerformIntHistoryTimeEntry adFRPerformIntHistoryTimeSlotIndex Integer RO adFRPerformIntHistorySlotTotalTime Integer RO adFRPerformIntHistoryTimeStamp DisplayString RO adFRPerformDayPvcStatus adFRPerformDayPvcStatusTable ...

Страница 410: ...zeTx Counter RO adFRPerformDayPVCMaxFrameSizeRx Counter RO adFRPerformDayPVCMaxFrameSizeTx Counter RO adFRPerformDayPVCAvgFrameSizeRx Gauge RO adFRPerformDayPVCAvgFrameSizeTx Gauge RO adFRPerformDayPVCLostFrames Counter RO adFRPerformDayPVCRemoteLostFrames Counter RO adFRPerformDayPVCMaxDelay Gauge RO adFRPerformDayPVCMinDelay Gauge RO adFRPerformDayPVCAvgDelay Gauge RO adFRPerformDayPVCTimeInDBU ...

Страница 411: ...me Counter RO adFRPerformDayCrcErrors Counter RO adFRPerformDayAbortFrames Counter RO adFRPerformDayOctectViolations Counter RO adFRPerformDayDiscardFrames Counter RO adFRPerformDayLengthErrors Counter RO adFRPerformDayEAViolations Counter RO adFRPerformDayEncapsulationErrors Counter RO adFRPerformDayInactiveDLCI Counter RO adFRPerformDayInvalidDLCI Counter RO adFRPerformDayUnroutable Counter RO a...

Страница 412: ...Section 9 MIBs ATLAS 550 System Manual 412 2004 ADTRAN Inc 61200305L2 1B ...

Отзывы: