ATLAS 550 System Manual
Section 7 System Event Logging
61200305L2-1B
© 2004 ADTRAN, Inc.
369
3.
SYSTEM EVENTS
The following tables provide a listing of ATLAS system events. This includes tables of events for each
category, according to the order they appear in the
E
VENT
L
OG
setup screen.
Table 1. System Controller Events
Console Log String
Category
Event
“-24 V Power Failure Cleared”
CRITICAL
-24 V power supply is functioning normally again
“-24 V Power Failure”
CRITICAL
-24 V power supply is not operating properly
“-58 V Power Failure Cleared”
CRITICAL
-58 V power supply is functioning normally again
“-58 V Power Failure”
CRITICAL
-58 V power supply is not operating properly
>70 Internal Temperature Warning Cleared
CRITICAL
Internal system temperature has cooled below 70
o
C
>70C Internal Temperature Warning
CRITICAL
Internal system temperature is greater than 70
o
C
>85 Internal Temperature Warning Cleared
CRITICAL
Internal system temperature has cooled below 85
o
C
>85C Internal Temperature Warning
CRITICAL
Internal system temperature is greater than 85
o
C
ACO Switch pressed
MINOR
ACO switch pressed
Cold
NORMAL
System cold start
a
a
Generated five seconds after the completion of system initialization.
External Alarm Cleared
MINOR
External alarm cleared
External Alarm Detected
MINOR
Alarm detected on External Alarm Monitor
Firmware invalid
CRITICAL
Corrupted firmware
Firmware update completed
INFO
Flash download successful
Firmware update failed
CRITICAL
Flash download failed
Login Failure
MINOR
Console login failure
b
b
Three consecutive logins were attempted and failed.
Module Found
INFO
Module found
Module Not Responding
WARNING
Module removed or not responding
Not responding to programming
MINOR
Unable to program module
SNMP Authentication Failure
INFO
SNMP authentication failure
c
c
Generated if the ATLAS receives an SNMP request from an SNMP manager defined in the ATLAS SNMP
communities list but with a community name that does not match the community name defined in the SNMP
communities list.
System Configuration Uploaded
CRITICAL
ATLAS configuration file loaded into the system and
activated
Timing source changed to Backup
MINOR
The primary source is not backup valid
Timing source changed to Internal
MINOR
Neither the primary nor the backup are valid
Timing source changed to Primary
MINOR
The timing source changed to primary
Содержание ATLAS 550
Страница 16: ...Table of Contents ATLAS 550 System Manual 16 2004 ADTRAN Inc 61200305L2 1B ...
Страница 24: ...Section 1 System Description ATLAS 550 System Manual 24 2004 ADTRAN Inc 61200305L2 1B ...
Страница 62: ...Section 3 Network Turnup Procedure ATLAS 550 System Manual 62 2004 ADTRAN Inc 61200305L2 1B ...
Страница 308: ...Section 4 User Interface Guide ATLAS 550 System Manual 308 2004 ADTRAN Inc 61200305L2 1B ...
Страница 310: ...Section 5 Detail Level Procedures ATLAS 550 System Manual 310 2004 ADTRAN Inc 61200305L2 1B ...
Страница 320: ...Section 5 DLP 4 ATLAS 550 System Manual 320 2004 ADTRAN Inc 61200305L2 1B ...
Страница 326: ...Section 5 DLP 6 ATLAS 550 System Manual 326 2004 ADTRAN Inc 61200305L2 1B ...
Страница 330: ...Section 5 DLP 7 ATLAS 550 System Manual 330 2004 ADTRAN Inc 61200305L2 1B ...
Страница 348: ...Section 5 DLP 14 ATLAS 550 System Manual 348 2004 ADTRAN Inc 61200305L2 1B ...
Страница 351: ...61200305L2 1B 2004 ADTRAN Inc 351 CONFIGURATION GUIDES CFG 1 Dial Backup for Dedicated T1 Circuits 353 ...
Страница 352: ...Section 6 Configuration Guides ATLAS 550 System Manual 352 2004 ADTRAN Inc 61200305L2 1B ...
Страница 364: ...Section 6 CFG 1 ATLAS 550 System Manual 364 2004 ADTRAN Inc 61200305L2 1B ...
Страница 378: ...Section 7 System Event Logging ATLAS 550 System Manual 378 2004 ADTRAN Inc 61200305L2 1B ...
Страница 388: ...Section 8 ADTRAN Utilities ATLAS 550 System Manual 388 2004 ADTRAN Inc 61200305L2 1B ...
Страница 412: ...Section 9 MIBs ATLAS 550 System Manual 412 2004 ADTRAN Inc 61200305L2 1B ...