Section 4 User Interface Guide
ATLAS 550 System Manual
76
© 2004 ADTRAN, Inc.
61200305L2-1B
S
YSTEM
S
TATUS
> C
HAIN
P
ORT
> C
LEAR
C
OUNTERS
Write security: 5; Read security: 5
Clears the
ADMIN
or
CRAFT
port statistics. Press
Y
to activate this command.
S
YSTEM
S
TATUS
> S
YSTEM
T
EMPERATURE
A
LARMS
Read security: 5
Indicates that the internal temperature of the unit has exceeded normal operating limits. The two thresholds
indicate that the internal temperature is greater than 70ºC
and greater than 85ºC. If one of these thresholds
is exceeded, a warning will be placed in the
E
VENT
L
OG
(see Section 7,
System Event Logging
for more
details) but no other action will be taken. The following status symbols are used:
S
YSTEM
S
TATUS
> S
YSTEM
P
OWER
A
LARMS
Read security: 5
Indicates that the -58V and/or -24V power supplies are not functional. These power supplies are
continuously monitored to determine failures. If one of these supplies fails, a message will be placed in the
E
VENT
L
OG
(see Section 7,
System Event Logging
for more details). The following status symbols are
used:
S
YSTEM
S
TATUS
> S
YSTEM
T
IMING
S
OURCE
Read security: 5
Indicates which timing source (primary or backup) is currently being used by ATLAS 550 and whether the
system is locked onto this source. If the display does not indicate locked, the ATLAS 550 does not have a
valid source of timing and cannot reliably transfer data. Review the current setting for system timing
source in the
S
YSTEM
C
ONFIG
menu. See
System Config > Primary Timing Source
on page 80 and
System
Config > Backup Timing Source
on page 80 for details.
S
YSTEM
S
TATUS
> R
ESOURCE
U
SAGE
Write security: 5; Read security: 5
Provides resource usage tracking for dynamic resources throughout the system. This includes current,
average, and minimum availability for both analog and digital resources.
S
YSTEM
S
TATUS
> R
ESOURCE
U
SAGE
> D
ATA
T
ABLES
Read security: 5
Displays resource usage for dynamic resources throughout the system in a table format.
[–]
Normal condition
[*]
Failure condition
[!]
No Information Available
[–]
Normal condition
[*]
Failure condition
[!]
No Information Available
Содержание ATLAS 550
Страница 16: ...Table of Contents ATLAS 550 System Manual 16 2004 ADTRAN Inc 61200305L2 1B ...
Страница 24: ...Section 1 System Description ATLAS 550 System Manual 24 2004 ADTRAN Inc 61200305L2 1B ...
Страница 62: ...Section 3 Network Turnup Procedure ATLAS 550 System Manual 62 2004 ADTRAN Inc 61200305L2 1B ...
Страница 308: ...Section 4 User Interface Guide ATLAS 550 System Manual 308 2004 ADTRAN Inc 61200305L2 1B ...
Страница 310: ...Section 5 Detail Level Procedures ATLAS 550 System Manual 310 2004 ADTRAN Inc 61200305L2 1B ...
Страница 320: ...Section 5 DLP 4 ATLAS 550 System Manual 320 2004 ADTRAN Inc 61200305L2 1B ...
Страница 326: ...Section 5 DLP 6 ATLAS 550 System Manual 326 2004 ADTRAN Inc 61200305L2 1B ...
Страница 330: ...Section 5 DLP 7 ATLAS 550 System Manual 330 2004 ADTRAN Inc 61200305L2 1B ...
Страница 348: ...Section 5 DLP 14 ATLAS 550 System Manual 348 2004 ADTRAN Inc 61200305L2 1B ...
Страница 351: ...61200305L2 1B 2004 ADTRAN Inc 351 CONFIGURATION GUIDES CFG 1 Dial Backup for Dedicated T1 Circuits 353 ...
Страница 352: ...Section 6 Configuration Guides ATLAS 550 System Manual 352 2004 ADTRAN Inc 61200305L2 1B ...
Страница 364: ...Section 6 CFG 1 ATLAS 550 System Manual 364 2004 ADTRAN Inc 61200305L2 1B ...
Страница 378: ...Section 7 System Event Logging ATLAS 550 System Manual 378 2004 ADTRAN Inc 61200305L2 1B ...
Страница 388: ...Section 8 ADTRAN Utilities ATLAS 550 System Manual 388 2004 ADTRAN Inc 61200305L2 1B ...
Страница 412: ...Section 9 MIBs ATLAS 550 System Manual 412 2004 ADTRAN Inc 61200305L2 1B ...