372 Parameters
Activates master/follower communication monitoring
separately for each control location (see section
The parameter is primarily intended for monitoring the
communication with master or follower when it is connected to
the application program and not selected as a control source
by drive parameters.
0000b
0000b…0111b
Master/follower communication monitoring selection.
1 = 1
Selects the channel used for connecting an optional FEA-xx
extension adapter.
No connect
None (communication disabled).
0
Slot 1A
Channel A on FDCO module in slot 1.
1
Slot 2A
Channel A on FDCO module in slot 2.
2
Slot 3A
Channel A on FDCO module in slot 3.
3
Slot 1B
Channel B on FDCO module in slot 1.
4
Slot 2B
Channel B on FDCO module in slot 2.
5
Slot 3B
Channel B on FDCO module in slot 3.
6
RDCO CH 3
Channel CH 3 on RDCO module (with BCU control unit only). 13
In ModuleBus communication, defines whether the drive is of
the “engineered” or “standard” type.
Note:
This parameter cannot be changed while the drive is
running.
ABB engineered
drive
The drive is an “engineered drive” (data sets 10…25 are
used).
0
ABB standard drive
The drive is a “standard drive” (data sets 1…4 are used).
1
Selects the DDCS channel used for connecting an external
controller (such as an AC 800M).
Not in use
None (communication disabled).
0
Slot 1A
Channel A on FDCO module in slot 1.
1
Slot 2A
Channel A on FDCO module in slot 2.
2
Slot 3A
Channel A on FDCO module in slot 3.
3
Slot 1B
Channel B on FDCO module in slot 1.
4
Slot 2B
Channel B on FDCO module in slot 2.
5
Slot 3B
Channel B on FDCO module in slot 3.
6
RDCO CH 0
Channel 0 on RDCO module (with BCU control unit only).
10
XD2D
Connector XD2D.
7
No.
Name/Value
Description
Def
/
FbEq16
Bit
Name
Value
0
Ext 1
1 = Communication monitoring active when Ext 1 is being used.
1
Ext 2
1 = Communication monitoring active when Ext 2 is being used.
2
Local
1 = Communication monitoring active when local control is being
used.
3…15
Reserved
Содержание ACS880-x04
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Страница 4: ......
Страница 18: ...18 Using the control panel ...
Страница 24: ...24 Control locations and operating modes ...
Страница 111: ...Application macros 111 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 112: ...112 Application macros ...
Страница 496: ...496 Additional parameter data ...
Страница 544: ...544 Fault tracing ...
Страница 602: ...602 Control chain diagrams ...