Parameters 441
Advanced
ID run.
6
Advanced Standstill
ID run.
7
Calculated number of pole pairs in the motor.
This parameter is read-only.
0
0…1000
Number of pole pairs.
1 = 1
Switches the rotation direction of motor. This parameter can
be used if the motor turns in the wrong direction (for example,
because of the wrong phase order in the motor cable), and
correcting the cabling is considered impractical.
Notes:
• Changing this parameter does not affect speed reference
polarities, so positive speed reference will rotate the motor
forward. The phase order selection just ensures that
“forward” is in fact the correct direction.
• After changing this parameter, the sign of encoder
feedback (if any) must be checked. This can be done by
setting parameter
, and comparing the sign of
(or
). If the sign of the measurement is incorrect, the
encoder wiring must be corrected or the sign of
reversed.
• This parameter cannot be changed while the drive is
running.
U V W
Normal.
0
U W V
Reversed rotation direction.
1
Defines the inductance of a custom sine filter, ie. when
parameter
bit 3 is activated.
Note:
For an ABB sine filter (
bit 1),
this parameter is set automatically and should not be
adjusted.
-
0.000 …
100000.000 mH
Inductance of custom sine filter.
1000 = 1 mH
No.
Name/Value
Description
Def
/
FbEq16
Содержание ACS880-x04
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Страница 4: ......
Страница 18: ...18 Using the control panel ...
Страница 24: ...24 Control locations and operating modes ...
Страница 111: ...Application macros 111 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 112: ...112 Application macros ...
Страница 496: ...496 Additional parameter data ...
Страница 544: ...544 Fault tracing ...
Страница 602: ...602 Control chain diagrams ...