396 Parameters
Pos counter error
and boot action
Selects how the position counter reacts to loss of load
feedback.
Request re-
initialization
is cleared. Reinitialization of
position counter is recommended.
0
Continue from
previous value
Position counting resumes from the previous value over a loss
of load feedback or control unit reboot. Bit 4 of
is not cleared, but bit 6 is set to indicate that an
error has occurred.
WARNING!
If load feedback is lost when the drive is in
stopped state or not powered, the counter is not
updated even if the load moves.
1
and
define a gear function between
the motor and load speeds.
(page
).
1
-2147483648 …
2147483647
Gear numerator (motor-side).
-
See parameter
1
-2147483648 …
2147483647
Gear denominator (load-side).
-
and
define the feed constant for the
position calculation:
The feed constant converts rotational motion into translatory
motion. The feed constant is the distance the load moves
during one turn of the motor shaft.
The translatory load position is shown by parameter
. Note that the load position is only
updated after new position input data is received.
1
-2147483648 …
2147483647
Feed constant numerator.
-
See parameter
.
1
-2147483648 …
2147483647
Feed constant denominator.
-
Defines an initial position (or distance) for the position counter
(as a decimal number) when parameter
is set to
The number of decimal places is defined by parameter
0.000
-2147483.648 …
2147483.647
Initial value for position counter.
-
Selects the source of the initial position value. When the
source selected by
activates, the value selected in this parameter is assumed to
be the position of the load (in decimal format).
Zero
0.
0
No.
Name/Value
Description
Def
/
FbEq16
Motor speed
Load speed
=
Содержание ACS880-x04
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Страница 4: ......
Страница 18: ...18 Using the control panel ...
Страница 24: ...24 Control locations and operating modes ...
Страница 111: ...Application macros 111 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 112: ...112 Application macros ...
Страница 496: ...496 Additional parameter data ...
Страница 544: ...544 Fault tracing ...
Страница 602: ...602 Control chain diagrams ...