Parameters 289
Displays the actual present value of signal edge counter 2.
The counter is incremented every time the signal selected by
parameter
switches on or off (or
either, depending on the setting of
). A divisor may be applied to the count (see
).
When the counter exceeds the limit set by
, bit 3 of
is set to 1. The
also given if enabled by
.
The counter can be reset from the Drive composer PC tool, or
from the control panel by keeping Reset depressed for over 3
seconds.
-
0…4294967295
Actual present value of signal edge counter 2.
-
Sets the warning limit for signal edge counter 2.
0
0…4294967295
Warning limit for signal edge counter 2.
-
Configures signal edge counter 2.
0000b
0000b…1111b
Edge counter 2 configuration word.
1 = 1
Selects the signal to be monitored by signal edge counter 2.
False
0.
0
True
1.
1
RO1
(page
2
Source selection (see
). -
Defines a divisor for signal edge counter 2. Determines how
many signal edges increment the counter by 1.
1
1…4294967295
Divisor for signal edge counter 2.
-
No.
Name/Value
Description
Def
/
FbEq16
Bit
Function
0
Counter mode
0 = Loop: When the limit is reached, the counter is reset. The counter status (bit 3 of
) remains 1 until the counter is again incremented. The warning (if enabled) stays
active for at least 10 seconds.
1 = Saturate: After the limit is reached, the counter status (bit 3 of
) remains 1 until
is reset. The warning (if enabled) also stays active until
is reset.
1
Warning enable
0 = Disable: No warning is given when the limit is reached
1 = Enable: A warning (see
) is given when the limit is reached
2
Count rising edges
0 = Disable: Rising edges are not counted
1 = Enable: Rising edges are counted
3
Count falling edges
0 = Disable: Falling edges are not counted
1 = Enable: Falling edges are counted
4…15
Reserved
Содержание ACS880-x04
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Страница 4: ......
Страница 18: ...18 Using the control panel ...
Страница 24: ...24 Control locations and operating modes ...
Страница 111: ...Application macros 111 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 112: ...112 Application macros ...
Страница 496: ...496 Additional parameter data ...
Страница 544: ...544 Fault tracing ...
Страница 602: ...602 Control chain diagrams ...