Parameters 353
Displays the fieldbus adapter module mapping file revision
stored in the memory of the drive in decimal format.
This parameter is read-only.
-
0…65535
Mapping file revision.
1 = 1
Displays the status of the fieldbus adapter module
communication.
-
Not configured
Adapter is not configured.
0
Initializing
Adapter is initializing.
1
Time out
A timeout has occurred in the communication between the
adapter and the drive.
2
Configuration error
Adapter configuration error: mapping file not found in the file
system of the drive, or mapping file upload has failed more
than three times.
3
Off-line
Fieldbus communication is off-line.
4
On-line
Fieldbus communication is on-line, or fieldbus adapter has
been configured not to detect a communication break. For
more information, see the documentation of the fieldbus
adapter.
5
Reset
Adapter is performing a hardware reset.
6
Displays the patch and build versions of the adapter module
firmware in format xxyy, where xx = patch version number, yy
= build version number.
Example: C802 = 200.02 (patch version 200, build version 2).
Patch and build versions of adapter module firmware.
-
Displays the major and minor versions of the adapter module
firmware in format xyy, where x = major revision number, yy =
minor revision number.
Example: 300 = 3.00 (major version 3, minor version 00).
Major and minor versions of adapter module firmware.
-
52
Selection of data to be transferred from drive to fieldbus
controller through fieldbus adapter A.
Note:
32-bit values require two consecutive parameters.
Whenever a 32-bit value is selected in a data parameter, the
next parameter is automatically reserved.
Parameters
select data to be transferred from
the drive to the fieldbus controller through fieldbus adapter A.
None
None.
0
CW 16bit
Control Word (16 bits)
1
Ref1 16bit
Reference REF1 (16 bits)
2
Ref2 16bit
Reference REF2 (16 bits)
3
SW 16bit
Status Word (16 bits)
4
Act1 16bit
Actual value ACT1 (16 bits)
5
Act2 16bit
Actual value ACT2 (16 bits)
6
CW 32bit
Control Word (32 bits)
11
Ref1 32bit
Reference REF1 (32 bits)
12
Ref2 32bit
Reference REF2 (32 bits)
13
SW 32bit
Status Word (32 bits)
14
No.
Name/Value
Description
Def
/
FbEq16
Содержание ACS880-x04
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Страница 4: ......
Страница 18: ...18 Using the control panel ...
Страница 24: ...24 Control locations and operating modes ...
Страница 111: ...Application macros 111 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 112: ...112 Application macros ...
Страница 496: ...496 Additional parameter data ...
Страница 544: ...544 Fault tracing ...
Страница 602: ...602 Control chain diagrams ...