Controlling with External Analog & Contact Signals
------------------------------------------------------------------------------------
120
Using External Control Terminals (ZX-S Series Type-HA)
This section covers proper methods when operating the ZX-S-HA Series Power Supply externally.
The External Control Terminal is located on the rear panel of the power supply.
(A connector is provided for the terminal. Combined with FUNCTION items, this terminal can be
applied in various means.)
A specialized connector is attached to the ZX-S-HA Series.
Terminal
No.
Signal Name
1
External ON/OFF Terminal
2
External ON/OFF, Input Cut-0ff
COM
3
Monitor Terminal
For Output Current
4
Analog COM
5
Output Voltage Control Terminal
External Voltage Input Terminal
(+)
6
Output Voltage/Current Control
Terminal
External Resistance Terminal (A
Curve)
7
Output Voltage Control Terminal
External Resistance Terminal (B,
C Curve)
8
Output Current Control Terminal
External Resistance Terminal (A
Curve)
9
Output Current Control Terminal
External Resistance Terminal
(B, C Curve)
10
NC
11
Status Output
LEVEL1_ALM
12
Status Output
CV
13
Status Output
P-ON
14
Input Cut-Off Terminal
15
Monitor Terminal
For Output Voltage
16
Analog COM
17
Analog COM
18
Output Voltage Control Terminal
External Resistance Terminal (A
Curve)
19
Output Voltage Control Terminal
External Resistance Terminal (B,
C Curve)
20
Output Current Control Terminal
External Voltage Input Terminal
(+)
21
Output Current Control Terminal
External Resistance Terminal (B,
C Curve)
22
Series Operation Control Terminal
23
NC
LEVEL2_ALM
24
Status Output
Level2_ALM
25
Status Output
CC
26
Status COM
IN
OUT
1
13
26
14
外部コントロール用
コネクタ
直列コントロール用
コネクタ
外部コントロール用
コネクタ(付属)
1
13
26
14
ロックレバー
Series Control
Connector
External Control
Connector
External Control
Connector (Accessory)
Lock Lever
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...