Controlling with External Analog & Contact Signals
------------------------------------------------------------------------------------
123
Input Cut-Off with External Contacts (ZX-S Series Type-HA)
The input for ZX-S Series power supplies can be cut off (stop switching) using outputs from small capcity
contacts or photocouplers.
Use a photocoupler or a small signal relay or switch with a minimum contact capcity of 5V, 2.5mA.
Connecting
Wire the cables to the external control connector (accessory) terminal’s No. 14 and 2.
The external control connectors can be simply removed by lowering the lock levers on both sides.
14
ツイストペア線
接点
フォトカプラ
または
接点閉:入力しゃ断
外部接点による、入力のしゃ断
IN
OUT
14
2
Shutdowning with short circuit (make) of contact b is standard.
Shutdowning with opening (break) of contact a by option is also possible.
(Please contact TAKASAGO.)
● Not suited for power contacts such as main contacts for electromagnetic contactors or
power relays etc.
● For the output ON/OFF toggle contact point, please use an insulated contact point or open
collector at the photocoupler.
Caution
MEMO
Photocoupler or Contact
Twisted-Pair Wire
Closed: Input Cut Off
Input Cut-Off with External Contacts
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...