Using via Digital Data Communication
------------------------------------------------------------------------------------
95
SYSTem:TRIP:MODE
:Sets Operation for Stopping Output During Serious Failure
Function: Sets the operation for stopping the output during a serious failure
Same settings as FUNCTION Settings Item 10
Format:SYSTem:TRIP:MODE <NRf>
Type:SET command, QUERY command
Parameters: 0 ・・・Stop switching
1 ・・・Execute input power relay trip (When TRIP is detected or serious failure)
2 ・・・Execute input power relay trip
(When TRIP is detected, severe breakdown, OVP/OCP triggered).
Restrictions: Alarm response is returned for normal SET commands in the following conditions.
・All ZX Series power supplies excluding 1600W models. (SET command only)
・While operating as a parallel operation slave unit
・
Sequence operation in progress
<Ex.>
SYST:TRIP:MODE 1
SYST:TRIP:MODE?
1
●Serious failure is defined as when an alarm cannot be canceled via command or by panel reset (holding down the A
and C key).
(Restart device with power switch)
●Serious failure Error
See page 32 for details on WDT, OHP, AD-OV, P_ERR, BST ALM, Device Detection Failure, and Device No.
Disagreement error codes..
Caution
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...