Control with External Analog & Contact Signals
------------------------------------------------------------------------------------
124
Output Voltage Control (ZX-S Series Type-HA)
Output Voltage Control with External Resistance
1.Output Voltage Control with External Resistance (A)
This sections describes how to set the output voltage zero when
the external resistance value is infinity.
The output voltage is derived from the following formula.
Output Voltage[V]=Max. Output Voltage[V]
×
The output accuracy for the external resistance,
is the set voltage±(0.2%
of Rated Output Voltage) when 10kΩ.
Connecting
Connect the resistor to accessory connector terminals No. 6 and 18.
IN
OUT
18
6
外部抵抗
0~∞
Ω
Setting Procedures
Set to parameter 2 (External Resistance Type A) according to the procedure on page 125.
The External Resistance A, B, and C and the External Voltage cannot be used
together to control the output.
Caution
MAX
∞
0
外部抵抗
出
力
電
圧
CV_RA
10k
Ω
MAX
1
2
External Resistance
Output v
olt
age
External
Resistance
10
External Resistance[k
Ω
]
+
10
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...