Using via Digital Data Communication
------------------------------------------------------------------------------------
71
OUTPut:HOT
: Sets Output status while POWER is ON
Function: Sets Output status while POWER is ON
Same settings as FUNCTION Settings Item 51
Format:OUTPut:HOT <NRf>
Type:SET command, QUERY command
Paramters: 0…OFF
1…MODE1(HOT START)
HOT START is valid also when recovered from ALM or TRIP
2…MODE2(HOT START)
Powers up with OUTPUT status OFF when recovered from ALM or TRIP
HOT START is valid again on next startup.
Response: Same as parameters
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as a series operation slave unit
・While operating as a parallel operation slave unit
・
Sequence operation in progress
<Ex.>
OUTP:HOT 1
OUTP:HOT?
1
OUTPut:MODE
:Sets Startup Mode
Function: Sets the Output Startup Mode
Same settings as FUNCTION Settings Item 2
Format:OUTPut:MODE <NRf>
Type:SET command, QUERY command
Paramters: 0…CV Priority, High Speed
1…CC Priority, High Speed
2…CV Priority, Slew Rate can be set
3…CC Priority, Slew Rate can be set
Response: Same as parameters
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as a series operation slave unit
・While operating as a parallel operation slave unit
・
Sequence operation in progress
<Ex.>
OUTP:MODE 3
OUTP:MODE?
3
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...