138
特殊な負荷
This section explains about charging and discharging of batteries, loads with reverse current, and
pulse current loads as special loads.
Battery Charging/Discharging
Charging Battery
Batteries can be charged by constant-current automatically.
Set the charge current and charge terminal voltage beforehand.
Connecting
Connect as shown in the below diagram. D1 acts as a reverse current blocking diode by
preventing surge currents from flowing into the power supply's output capacitor when
connecting the battery.
Note the reverse voltage and current capacity when selecting D1. In general, when charge
current is above 2A, it is necessary to cool D1 by attaching an appropriate radiator to it.
Connection for Battery Charging
Set the OUTPUT key settings to TOGGLE when the input
power switch is turned ON.
(Factory default settings)
Press The Function “FUNC.” key.
FUNC. lamp will light.
Settings Item Number (top) and parameters (bottom) will appear in the Number Display.
Select Item number 51 with the VOLTAGE dial and
set the value to 0 with the CURRENT dial.
OUTPUT
PRESET
OVP
OCP
FUNC.
ALARM RESET
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
The power supply internals will burn out if the battery polarity is connected in reverse.
To prevent this, it is recommended to use fuses (F1).
Caution
Power Supply
+
-
D1
Battery
F1
+
-
⇒Continued on next page
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...