Using via Digital Data Communication
------------------------------------------------------------------------------------
98
SEQuence:MEMB
:Sets Memory B Operating Time
Function:Sets the memory B operating time
Same settings as FUNCTION Settings Item 105~107
Format:SEQuence:MEMB[]※1,※2,※3
Type:SET command, QUERY command
Parameters:※1 0~999(h)
※2 0~59(m)
※3 0.0~59.9(s)
Response:Same as parameters
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as a series operation slave unit
・While operating as a parallel operation slave unit
・
Sequence operation in progress
<Ex.>
SEQ:MEMB[]100,10,10.0
SEQ:MEMB?
100,10,10.0
SEQuence:MEMC
:Sets Memory C Operating Time
Function:Sets the memory C operating time
Same settings as FUNCTION Settings Item 108~110
Format:SEQuence:MEMC[]※1,※2,※3
Type:SET command, QUERY command
Parameters:※1 0~999(h)
※2 0~59(m)
※3 0.0~59.9(s)
Response:Same as parameters
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as a series operation slave unit
・While operating as a parallel operation slave unit
・
Sequence operation in progress
<Ex.>
SEQ:MEMC[]100,10,10.0
SEQ:MEMC?
100,10,10.0
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...