Using via Digital Data Communication
------------------------------------------------------------------------------------
58
Serial Port Settings
Below is the serial port settings for ZX-S Series power supplies.
Serial Port Settings
Item
Set Value Ranges
Bitrate
2400、9600、19200、38400bps
Data Length
8bit (fixed)
Parity
NOT、ODD、EVEN
Stop Bit
1bit (fixed)
Flow Control
None
※The underlined items are used in the default settings.
Please adjust communication terminal serial port settings with ZX power supply serial port settings.
Communication cannot be established if settings differ. Set the bitrate and parity under FUNCTION Setting
Item 61 “Bitrate” and Item 62 “Parity” (See page 22). Setting changes will take affect from next startup.
Command Send Interval
When sending commands continuously to the ZX-S power supply due to there being no flow control function, a
delay is required on the communication terminal side.
If receiving has failed, the ZX Series power supply will return an alarm response “ALM 128”.
Standard command send intervals are shown below.
Command Send Intervals
Bitrate
Delay Time
2400bps
200ms
9600bps
50ms
19200bps
40ms
38400bps
20ms
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...