Controlling with External Analog & Contact Signals
------------------------------------------------------------------------------------
125
Setting Procedures
Press the Function “FUNC.” key.
FUNC. lamp will light.
Settings Item Number (top) and parameters (bottom) will appear
in the Number Display.
Select Item number 70 (Output Voltage Control) with the VOLTAGE dial.
Change the parameter with the CURRENT dial.
1=External Voltage (0~10V)
2=External Resistance (0~∞Ω:A)
3=External Resistance (0~∞Ω:B)
4=External Resistance (0~∞Ω:C)
Press the FUNC. key again to finish.
Returns Number Display back to measurement display mode.
Canceling Output Voltage Control via External Voltage/Resistance
To cancel, select Item number 70 and set the parameter to 0 with the CURRENT dial.
OUTPUT
PRESET
OVP
OCP
FUNC.
ALARM RESET
OUTPUT
PRESET
OVP
OCP
FUNC.
ALARM RESET
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...