Using via Digital Data Communication
------------------------------------------------------------------------------------
80
[SOURce]:CURRent:SLEW:FALLing
:Sets CC Slew Rate Falling
Function: Sets the CC slew rate for falling
Same settings as FUNCTION Settings Item 6
Format:[SOURce]:CURRent:SLEW:FALLing <NRf>
Type:SET command, QUERY command
Parameters:Range varies on the model and the number of parallel connected devices.
See CC Slew Rate Ranges for range settings.
Response:Same as parameters
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as a series operation slave unit
・While operating as a parallel operation slave unit
<Ex.>
ZX-S-400H(Idependent Operation)
CURR:SLEW:FALL 10
CURR:SLEW:FALL?
10.00
[SOURce]:MEMory:RECall
:Loads from Panel Memory
Function:Loads from panel memory(A/B/C)
Format:[SOURce]:MEMory:RECall <String>
Type:SET command only
Parameters: A・・・Loads from panel memory A and overwrites current settings
B・・・Loads from panel memory B and overwrites current settings
C・・・Loads from panel memory C and overwrites current settings
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as a series operation slave unit
・While operating as a parallel operation slave unit
・
Sequence operation in progress
<Ex.>
MEM:REC A
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...