Specifications
------------------------------------------------------------------------------------
178
Measures/Displays
Specification/Models
400H
400HA
800H
800HA
1600H
1600HA
Voltmeter
4-Digit Digital Meter
Maximum Display
999.9V
Measure Accuracy
*13
±(0.1% of reading ±2digit(200mV))
Temperature Coefficient
(Typical Value)
±50ppm/℃
Ammeter
4-Digit Digital Meter
Maximum Display *21
9.999A
99.99A
99.99A
Measure Accuracy
*13 *21
±(0.5% of reading
±4digit(4mA))
±(0.5% of reading
±1digit(10mA))
±(0.5% of reading
±1digit(10mA))
Temperature Coefficient
(Typical Value) *21
±100ppm/℃
Power Meter
4-Digit Digital Meter
Maximum Display *21
999.9W
999.9W
9999W
Accuracy *21
Displays the multiplication value of the voltage measurement value and
current measurement value.
(Values under 0.1W are displayed rounded off.)
Power Display Bar Graph
Displays rough value of output power with 6-point LEDs
*13 : At environmental temperature 23℃±5℃
*21 : At stand alone operation