Maintenance
------------------------------------------------------------------------------------
146
Replacing Fan Motor
The lifespan of the fan motor when used at the rated output power is approximately 60,000 hours in a 25℃
temperature environment. If air flow decreases, there may be trash or dust stuck. Please first clean the air filter.
If air flow does not improve after cleaning or if noises are emitting from the fan, the fan motor should be replace.
1) Ready the new fan motor (connectors attached).
(Contact the Takasago sales department for place of purchase.)
2) Disconnect the power cable from the input power source.
(Or, in the case of the ZX-S-400H, 800H types, remove the input power cable from the rear inlet connector.)
3) Wait for at least 3 minutes for the internal voltage to decrease.
4) Remove and replace the fan motor as shown below.
Replacing Fan Motor
① Remove the four M3 screws attached to the fan motor. Pull out the fan motor.
② Disconnect the power wire connector (black) attached to the circuit board.
③ Connect the new fan motor’s connector. Insert the fan motor while being careful not to pinch the wire
between the fan motor and rear panel and screw in the four screws.
④ Connect to the input power supply and turn the POWER switch ON. Verify that the fan rotates.
Fan revolution responses to and is controlled by the output power and output current.
Therefore, if the output power or output current is low, air flow will decrease.
(The fan will rotate at a low speed if no load is attached.)
Replacement can be done by the owner. For this, a plus screwdriver for a 3mm screw is required.
MEMO
Fan Motor
Finger Guard
M3 Screw×4
※Diagram of ZX-S-400H
Only 400H/HA fan motors can be replaced.
Please contact the Takasago sales department to order the replacement of 800H/HA and 1600H/HA
fan motors.
Caution
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...