Using via Digital Data Communication
------------------------------------------------------------------------------------
91
SYSTem:ERRor
:Reads Error Message
Function:After an error response is received, send this command to retrive the cause for the generated error
Format:SYSTem:ERRor?
Type:QUERY command only
Response: Error Code, Error Message
Table-Error Codes & Error Messages
Error Code
Error Messages
Meaning
0
None
Normal
-100
Command error
Command Error (Undefined Command, etc.)
-101
Invalid character
Invalid character sent
-102
Syntax error
Syntax error
-104
Data type error
Data type error
Character received instead of numeral in parameter, etc.
-109
Missing parameter
Too few parameters
-120
Numeric data error
Numerical data error. Exceeds range, etc.
-140
Character data error
Character data error
-150
String data error
String data error
-900
Unmounted analog option board.
Cannot execute due to analog option board is unmounted
-901
Unmounted CP option board.
Cannot execute due to CP option board is unmounted
-902
No permission Command.
Command not permitted to execute.
( Attempted to execute a function which is only for
1600W models with slaves, with 400W or 800W models)
-903
Receive time out.
Receive time out
<Ex.>
RES?
ERROR
SYST:ERR?
-900,Unmount analog option board.
Can only be used for the last generated error response (newest error).
Caution
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...