Calibration
------------------------------------------------------------------------------------
172
Offset/Full-Scale Calibration of Output Voltage Monitor(ZX-S Series Type-HA)
1.Disconnect the load wires and connect the digital
multimeter No. 1 to the output terminal.
Connect the digital multimeter No. 2 to the external
control terminals number 4 and 15. (Voltage Monitor
Terminal)
Turn the POWER switch ON and OUTPUT OFF in
advance.
2.Press the FUNC. key and change the top Number
Display to Settings Item 13 with the VOLTAGE dial.
3.Turn the CURRENT dial and set the set value to 0
(Linearity Compensation: OFF).
4.Press the FUNC. key again to finalize settings.
5.Press the PRESET key ① again and set to “0.00V”
with the VOLTAGE dial ②.
6.Press the PRESET key ① and then the OUTPUT
key ② to set the output to ON.
Calibration Circuit
Digital
Multimeter
No.1
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
OUTPUT
PRESET
OVP
OCP
FUNC.
ALARM RESET
OUTPUT
PRESET
OVP
OCP
FUNC.
ALARM RESET
OUTPUT
PRESET
OVP
OCP
FUNC.
ALARM RESET
①
②
+
-
V
Power Supply
+
-
V
+
-
15
4
Digital
Multimeter
No.2
OUT PU T
PR ES ET
OVP
OCP
POWE R
FU NC.
LOCAL
LOCK
D ISPL AY
A
B
C
ST ORE
MEMOR Y
CC
CV
OUTPU T POWER
(%)
ST EP
CUR RE NT
ST EP
V OL TAGE
PRE SET FUN C. REMOTE LOCK
A LAR M R ESE T
20
60
100 LMT
40
80
①
②
ZX-S-400 H
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...