Using via Digital Data Communication
------------------------------------------------------------------------------------
81
[SOURce]:MEMory:RECall:MODE
:Sets Load Order for Panel Memory
Function: Sets the order of loading for panel memory(A/B/C)
Same settings as FUNCTION Settings Item 54
Format:[SOURce]:MEMory:RECall:MODE <NRf>
Type:SET command, QUERY command
Parameters: 0・・・Determines by Single-Action
1・・・Determines by Double-Action
Response:Same as parameters
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as a series operation slave unit
・While operating as a parallel operation slave uni
・
Sequence operation in progress
<Ex.>
MEM:REC:MODE 1
MEM:REC:MODE?
1
[SOURce]:MEMory:STORe
:Saves to Panel Memory
Function:Saves to panel memroy(A/B/C)
Format:[SOURce]:MEMory:STORe <String>
Type:SET command only
Parameters: A・・・Overwrites current settings to panel memory A
B・・・Overwrites current settings to panel memory B
C・・・Overwrites current settings to panel memory C
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as a series operation slave unit
・While operating as a parallel operation slave unit
・
Sequence operation in progress
<Ex.>
MEM:STOR A
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...