Specifications
------------------------------------------------------------------------------------
181
Input Cut-Off Control
Can be controlled at external contact or photocoupler
Status Output
The 5 points: CV(Constant Voltage), CC(Constant Current), P-ON(Input Voltage Normal),
LEVEL1_ALM(OVP, OCP), and LEVEL2_ALM(Group Alarm) are outputted by a photocoupler
insulated open collector.
Insulation/
Withstanding Voltage
Specification/Models
400H
400HA
800H
800HA
1600H
1600HA
Insulation
At DC 1000Vmega-ohm tester, above 20MΩ
Between each input and output, input and chassis, output and chassis
Withstanding Voltage
AC 1.5kV 1 minute
Between each input and output, input and chassis
Relative Ground Voltage
At peak voltage value, within ±1000V
between Output and Ground(Includes output voltage)
Cooling
Specification/Models
400H
400HA
800H
800HA
1600H
1600HA
Cooling Method
Cooling is regulated in response to the output
Operational Environment
Specification/Models
400H
400HA
800H
800HA
1600H
1600HA
Environmental
Temperature
Operating
0~50℃ However, in areas above 40℃ a 2.5% to 1℃ ratio is
required for derating the output power and output current.
Saving
-20℃~70℃
Humidity
Operating
20~80%RH
Saving
20~85%RH
Other
Do not place in cold environments, and areas with condensation and corrosive gases
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...