Using via Digital Data Communication
------------------------------------------------------------------------------------
86
*1 Status for factory adjustments of OVP and OCP. In practice, the status for then OVP and OCP are running is outputed to Bit4
OCP_ALM and Bit3 OVP_ALM.
*2 Booster refers to a ZX-S Series power supply that is running as a slave unit under parallel operation.
<Ex.>
STAT:MEAS:COND?
000184
(P-ON_B、P-ON_M、PL_STS represents state of 1.)
STATus:MEASure:PARallel
:Retrives No. of Parallel Connected Devices
Function:Retrives the number of device connected parallel (Total number of Parallel Operation Slave units
connected to the Master)
Format:STATus:MEASure:PARallel?
Type:QUERY command only
Response: 1~10
<Ex.>
STAT:MEAS:PAR?
1
(1 only represents the Master unit.)