Basic Operations
------------------------------------------------------------------------------------
23
Settings Items List (Continued)
【FUNCTION Settings Items】
Item
No.
Settings Items
Parameters and their Ranges
Default Value
13
General
F
unc
ti
ons
Linearity Compensation Function
Operatation Mode
0=Compensation Mode OFF
1 = Operates when Output is
turned ON/OFF or when
settings are changed.
Saves compensation value
after converging
1 = Operates when Output is
turned ON/OFF or when
settings are changed.
Saves compensation value
after converging
2=Performs continuous
compensation
20
Ca
librati
on
Voltage Setting Offset
Not displayed
21
Voltage Setting Full-Scale
Not displayed
22
Current Setting Offset
Not displayed
23
Current Setting Full-Scale
Not displayed
24
Voltage Measurement Offset
Not displayed
25
Voltage Measurement Full-
Scale
Not displayed
26
Current Measurement Offset
Not displayed
27
Current Measurement Full-
Scale
Not displayed
28
Ca
librati
on
(Z
X
-
S
T
ype
-
H
A
)
External
Analog
Input
Voltage Setting
Offset
Not displayed
29
Voltage Setting
Full-Scale
Not displayed
30
Current Setting
Offset
Not displayed
31
Current Setting
Full-Scale
Not displayed
32
Voltage Monitor Output Offset
Not displayed
33
Voltage Monitor Output Full-
Scale
Not displayed
34
Current Monitor Output Offset
Not displayed
35
Current Monitor Output Full-
Scale
Not displayed
36
-
-
37
Slave unit Voltage Offset
Not displayed
38
Slave unit Voltage Full-Scale
Not displayed
50
P
ane
l
Op
erati
on
Methods for Determining
PRESET Contents
0=Determines PRESET contents
after PRESET mode is complete
0=Determines
PRESET contents
after PRESET mode
is complete
1=Determines PRESET contents
during PRESET mode
を確定
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...