Using via Digital Data Communication
------------------------------------------------------------------------------------
106
OT
:Sets Output ON/OFF
Function:Sets the output ON/OFF
Format:OT* *:Set value
Set Value:
0:OUTPUT “OFF”
1:OUTPUT “ON”
Values other than 0 or 1 result in parameter errors.
<Ex.>A1,OT0
TP
:Executes Breaker Trip
Function:Executes breaker trip
Format:TP* *:Set values
Set Values:
0: Stop switching
1: Execute input power relay trip (When TRIP is detected or severe breakdown)
2: Execute input power relay trip (When TRIP is detected, severe breakdown, OVP/OCP triggered)
Values other than 0, 1, or 2 result in parameter errors.
<Ex.>A1,TP1
●Serious failure is defined as when an alarm can be canceled via command or by panel reset (holding down the A and
C key).
(Restart device with power switch)
●Serious failure Error
See page 32 for details on WDT, OHP, AD-OV, P_ERR, BST ALM, Device Detection Failure, and Device No.
Disagreement error codes.
●This command can only be used for 1600W models.
This is valid for 400W and 800W models. However nothing will happen if executed.
Caution
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...