Using via Digital Data Communication
------------------------------------------------------------------------------------
84
[SOURce]:VOLTage:SLEW:RISing
:Sets CV Slew Rate Rising
Function: Sets the CV slew rate for rising
Same settings as FUNCTION Settings Item 3
Format:[SOURce]:VOLTage:SLEW:RISing <NRf>
Type:SET command, QUERY command
Parameters: 1.0~1280.0
Response:Same as parameters
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as a series operation slave unit
・While operating as a parallel operation slave unit
・
Sequence operation in progress
<Ex.>
VOLT:SLEW:RIS 1280
VOLT:SLEW:RIS?
1280.0
[SOURce]:VOLTage:SLEW:FALLing
:Sets CV Slew Rate Falling
Function: Sets the CV slew rate for falling
Same settings as FUNCTION Settings Item 4
Format:[SOURce]:VOLTage:SLEW:FALLing <NRf>
Type:SET command, QUERY command
Parameters: 1.0~1280.0
Response:Same as parameters
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as a series operation slave unit
・While operating as a parallel operation slave unit
・
Sequence operation in progress
<Ex.>
VOLT:SLEW:FALL 1.0
VOLT:SLEW:FALL?
1.0
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...