Using via Digital Data Communication
------------------------------------------------------------------------------------
72
OUTPut[:STATe]
:Sets Output ON/OFF
Function:Sets the Output ON/OFF
Format:OUTPut[:STATe] <String>
Type:SET command, QUERY command
Paramters: ON…Output ON
OFF…Output OFF
Response: Same as parameter
Restrictions: Alarm response is returned for normal SET commands in the following conditions
・While operating as series operation slave unit
・While operating as parallle operation slave unit
<Ex.>
OUTP ON
OUTP?
ON
Summary of Contents for ZX-S-H Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual ...
Page 37: ...Basic Operations 33 This is blank page ...
Page 59: ...Useful Function 55 This is blank page ...
Page 115: ...Using via Digital Data Communication 111 This is blank page ...
Page 141: ...Controlling with External Analog Contact Signals 137 This is blank page ...
Page 147: ...Special Loads 143 This is blank page 守 ...
Page 188: ... 184 付録 External Diagrams ZX S 400H 400HA 4 M3 ...
Page 189: ...Appendix 185 ZX S 800H 800HA ...
Page 190: ...Appendix 186 ZX S 1600H 1600HA ...