Special Loads
------------------------------------------------------------------------------------
139
Select Item number 2 with the VOLTAGE dial and
set the value to 1 (CC priority, speed) or 3 (CC priority, straight)
with the CURRENT dial.
When finished, press the FUNC. key again to finalize settings.
Press the PRESET key and set the charge current with the CURRENT dial.
See “Operating as a Constant Current Power Supply” on how. ⇒page 19
Set the charge terminal voltage with the VOLTAGE dial.
Set only the forward voltage to D1, high (0.6V~0.8V).
When finished, press the FUNC. key again to finalize settings.
Press the OUTPUT key to begin testing.
As charging with the constant-current progresses,
switch to constant-voltage with the charge terminal voltage.
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
20
60
100 LMT
40
80
Set to either 1 or 3
OUTPUT
PRESET
OVP
OCP
FUNC.
ALARM RESET