Repairing the knitting machine
7
Needle selection shifting 7.6
380
Carry out restart with machine configuration:
✔
The machine is switched off.
1. To switch on the machine, set the main switch to
1
.
The "BootOkc" window is displayed on the touch screen.
"BootOkc" window
2. Touch the "Restart and Machine Configuration" key.
3. Tap repeatedly on the "Continue on to the next window" key until the
"Machine parameters" window is displayed. ("Language" -> "Machine
configuration" -> "Machine configuration 2" -> "Machine options" ->
"Machine parameters")
4. In the "Machine parameters" window tap on the "Additional function
keys" key.
5. Call up the "Machine parameters 2" window.
6. Select the impulse sensor type "2 - ID 260 396".
Select this setting also with mixed operation (old and new impulse
sensor type).
7. Confirm input.