Setting lubricating interval for needle bed
For the needle bed a lubricating interval of between 1 and 65.535 courses
can be set. A mean value for a three-system machine is 25,000 courses.
However, this value depends highly on: Machine speed, temperature and
number of knitting systems. We recommend: Selecting a shorter lubricating
interval instead of a longer one. After the lubricating interval expires, a
message appears stating that the needle bed must be oiled.
Set lubricating interval:
1. Call up the "Machine settings" window.
2. Call up "Additional function keys".
3. Call up the "Sensors" window.
"Sensors" window
4. Input "Syst. run through until lubric.".
5. If the machine is to be stopped after reaching the system run-throughs,
then deactivate the check box.
Key
Function
Call up the "Machine settings" window.
Call up "Additional function keys"
Call up "Sensors" window
Confirm input
Call up "Main menu"
Keys for setting the lubricating interval