Repairing the knitting machine
7
Replacing parts 7.3
342
7.3.5
Remove needle bed or position it at an angle
This chapter contains instructions on:
Releasing needle bed
Removing needle bed
Positioning the needle bed at an angle
Screwing on the needle bed tight
Releasing needle bed
1. Transfer all stitches of the needle bed to be removed or positioned
vertically to the other needle bed.
2. When the carriage assembly is in the left reversing position, stop the
machine with the engaging rod. If a central lubrication is present, the
carriage must be in the left reversing position.
3. Tap the "Rel. drive brake" key in the "Manual interventions" window and
slide the carriage assembly to the left up to the stop.
Releasing needle bed
4. Remove two screws (1) on each side of the machine.
Key
Function
Call up "Manual interventions" window
Key for calling up "Manual interventions" window
Summary of Contents for CMS 730 S
Page 12: ...8 ...
Page 58: ...Description of knitting machine 2 Display and operating elements 2 8 54 ...
Page 110: ...Producing with the knitting machine 3 Starting the machine after a fault 3 6 106 ...
Page 390: ...Repairing the knitting machine 7 Needle selection shifting 7 6 386 ...
Page 444: ...Yarns and stitch tension 9 Conversion table 9 4 440 ...
Page 460: ...Machine Management Tools 10 Send email directly from the machine 10 4 456 ...
Page 468: ...Key word directory 11 464 ...