Repairing the knitting machine
7
Replacing parts 7.3
350
Remove the carriage part
when the carriage assembly
is blocked in the needle bed
1. Call up "Manual interventions" window.
2. To switch off the needle selection, set the "Needle selection" switch to
"Off".
3. To switch off all yarn carriers, tap the "YC bolt Up" key.
4. Push all yarn carriers outward.
5. If a central lubrication is present, swivel it into mounting position.
6. Switch off 40 V power supply.
Cover of carriage assembly
7. Remove the carriage assembly cover (1).
8. If the rear carriage part is removed, the needle detector is to be
removed as well.
Needle detector
9. Mark the position of the needle detector so that it can be reassembled
in the same position.
10. Remove the suction tube on the carriage assembly.
Key
Function
Call up "Manual interventions" window
Key for calling up "Manual interventions" window