Repairing the knitting machine
7
Check fuses 7.5
374
7.5 Check fuses
7.5.1
Checking fuse (right and left control cabinet)
1. Set machine main switch to "0".
2. Wait until the touch screen is dark and an alarm signal sounds.
3. Check fuses (1) to (4) at the rear of the left control unit.
Fuses at rear of left control unit
Valid for:
CMS 530 T
CMS 730 S
CMS 730 T
CMS 740
CMS 822
CMS 830 C
CMS 830 S
CMS 933
DANGER
Life-threatening high voltage!
Electrical shock may cause death or serious injuries.
➜
Set the main switch to "0" and wait until the touch screen
is dark and an alarm signal sounds.
1 28 V (stop motions) (1A, slow-
blowing)
3 Yarn control device (1A, slow-
blowing)
2 STIXX (1A, slow-blowing)
4 Battery charging (1A, slow blowing)