7. MODBUS
IMS01T28-E4
7-9
7.2.2 Preset single register [06H]
The query message specifies data to be written into the designated holding register. The write data is
arranged in the query message with high-order 8-bit first and low-order 8-bit next. Only R/W holding
registers can be specified.
Example: Data is written into the holding register 008EH of slave address 1.
Query message
Slave address
01H
Function code
06H
Holding register number
High
00H
Low
8EH
Write data
High
00H
Low
64H
CRC-16 High
E8H
Low
0AH
Normal response message
Slave address
01H
Function code
06H
Holding register number
High
00H
Low
8EH
Write data
High
00H
Low
64H
CRC-16 High
E8H
Low
0AH
Error response message
Slave address
01H
80H
Function code
86H
Error code
02H
CRC-16 High
C3H
Low
A1H
Contents will be the same as query message data.