8. COMMUNICATION DATA LIST
IMS01T28-E4
8-19
Continued from the previous page.
No. Name
Iden-
tifier
Chan-
nel
Register address
Digits
Attri-
bute
Struc-
ture
Data range
Factory
set value
HEX DEC
82 Operation
mode
assignment 2
(Logic output
selection function)
Logic output 5 to 6
EB CH1
CH2
0336
0337
822
823
7 R/W
* C 0: No assignment
1: Operation mode
(Monitor/Control)
2: Operation mode
(Monitor
Event function/Control)
3: Auto/Manual
4: Remote/Local
5: Unused (Do not set this one)
0
83
SV select function
KM
CH1
CH2
033A
033B
826
827
1 R/W
* C 0: Remote SV function
1: Cascade control function
0
84
Remote SV function
master channel
module address
MC CH1
CH2
033E
033F
830
831
7 R/W
* C
1
(Master channel is selected from itself)
0 to 99
(Master channel is selected from other
modules)
1
85
Remote SV function
master channel
selection
MN CH1
CH2
0342
0343
834
835
7 R/W * C
1 to 99
1
86 Output
distribution
master channel
module address
DY CH1
CH2
0346
0347
838
839
7 R/W
* C
1
(Master channel is selected from itself)
0 to 99
(Master channel is selected from other
modules)
1
87 Output
distribution
master channel
selection
DZ CH1
CH2
034A
034B
842
843
7 R/W * C
1 to 99
1
88 Address of interacting
modules
RL CH1
CH2
034E
034F
846
847
7 R/W
* C
1
(Interact with its own module address)
0 to 99
(Interact with the addresses of other
modules)
1
89 Channel selection of
interacting modules
RM CH1
CH2
0352
0353
850
851
7 R/W * C
1 to 99
Becomes valid when the selected module
is “Z-TIO module.”
1
90 Selection switch of
interacting modules
RN CH1
CH2
0356
0357
854
855
7 R/W
* C
RKC communication
Least significant digit:
Memory
area
number
2nd digit: Operation mode
3rd digit: Auto/Manual
4th digit: Remote/Local
5th digit Unused
6th digit Interlock release
Most significant digit:
Suspension of area soak
time
Data 0: No interaction
1: Interact with other channels
Modbus
Bit data
Bit 0: Memory area number
Bit 1: Operation mode
Bit 2: Auto/Manual
Bit 3: Remote/Local
Bit 4: Unused
Bit 5: Interlock release
Bit 6: Suspension of area soak time
Bit 7 to Bit 15: Unused
Data 0: No interaction
1: Interact with other channels
[Decimal number: 0 to 111]
0
* During RUN (control), the attribute of Engineering setting data is RO. To configure Engineering setting data, the RUN/STOP switch must
be set to STOP (control stopped).
Continued on the next page.
Summary of Contents for Z-TIO-G
Page 8: ...i 6 IMS01T28 E4 MEMO...
Page 16: ...IMS01T28 E4 1 8 MEMO...
Page 22: ...2 6 IMS01T28 E4 MEMO...
Page 34: ...4 MOUNTING 4 4 IMS01T28 E4 4 2 Dimensions Terminal type module 85 100 5 Unit mm 30 6 7...
Page 52: ...5 14 IMS01T28 E4 MEMO...
Page 82: ...7 18 IMS01T28 E4 MEMO...
Page 211: ...TROUBLE SHOOTING IMS01T28 E4 10 1 10 1 Solutions for Problems 10 2...
Page 216: ...10 6 IMS01T28 E4 MEMO...
Page 217: ...SPECIFICATIONS IMS01T28 E4 11 1...
Page 230: ...11 14 IMS01T28 E4 MEMO...
Page 244: ...A 4 IMS01T28 E4 MEMO...
Page 245: ...The first edition SEP 2012 IMQ00 The fourth edition FEB 2019 IMQ00...