129
3-12-3 Laser frequency / pulse cycle: MPL
Sets the laser frequency (LP-GS/LP-RC) or pulse cycle (LP-RF/LP-RV) for the current file.
ンㄆㄇㄆㄓㄆㄏㄆ
• The settings by this command are applied to all objects in the file. With LP-RF/LP-RV series, if you want to change the
pulse cycle correction value of the specified object only, set the pulse cycle correction by each object setting.
• With LP-400/V compatible command mode, the available setting range of the pulse cycle for LP-RV series is limited. If
the setting value exceeds the limit, it is not possible to readout the settings by this command.
• For LP-RV series, the pulse duration is set to 30ns when you set the pulse cycle by this command.
⿎
Setting request data / response data for readout
Start
code
MPL
Sub
command
[Laser frequency/Pulse cycle]
LP-GS/LP-RC: 1-byte
LP-RF/LP-RV: 4-byte
(Check
sum)
End code
Sub command is “S” for the setting request data and “A” for the response data for readout.
⿎
Readout request data
Start
code
MPL
R
(Check sum)
End code
⿎
Data description
Name
Data length
[byte]
Data contents
Remarks
Laser frequency
or
Pulse cycle
1
or
4
Model
Setting range
LP-GS051(-L)
LP-GS052
“0”: 5 kHz
“1”: 10 kHz
“2”: 20 kHz
LP-RC350S
“3”: 40 kHz
LP-RF200P
“05.0”–“50.0” [μs]
LP-RV200P
“01.2”–“99.9” [μs]
• For LP-GS/LP-RC series, set the
laser frequency (1-byte).
• For LP-RF/LP-RV series, set the
pulse cycle (4-byte).
• For LP-RV series, the pulse duration
is set to 30ns when you set the
pulse cycle by this command.
Total data length
1
or
4
Fixed length.
• LP-GS/LP-RC series: 1-byte
• LP-RF/LP-RV series: 4-byte
⿎
Example of command settings
Condition:
LP-GS series, Laser frequency=20
• Setting
Transmission data
[STX]
MPL
S
2
[CR]
• Readout
Transmission data
[STX]
MPL
R
[CR]
Response data
[STX]
MPL
A
2
[CR]
Condition:
LP-RF series, Pulse cycle = 40
• Setting
Transmission data
[STX]
MPL
S
40.0
[CR]
• Readout
Transmission data
[STX]
MPL
R
[CR]
Response data
[STX]
MPL
A
40.0
[CR]
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...