99
⿎
Example of command settings
Condition:
Code type = Data matrix
Object No. = 1, System reserved value = 0, Code type = 20, Mode = 0,
Symbol size (vertical) = 24, Symbol size (horizontal) = 24,
X-position = 15, Y-position = -20, Rotation angle = 0, Module height = 1, Module width = 1
• Setting
Transmission data
[STX]
BRF
S
10015.000-020.000+000.00
1.0001.000
[CR]
• Readout
Transmission data
[STX]
BRF
R
1
[CR]
Response data
[STX]
BRF
A
10015.000-020.000+000.00
1.0001.000
[CR]