3-3 Operation Control Commands
3-3-1 Command reception permission: MKM
Controls the reception permission (reception mode ON/OFF) of the settings by communication commands.
In the shutter open or marking trigger ready ON status, set “command reception permission ON” when transmitting the
command including an action to update the laser marker data.
To resume the marking trigger ready ON status after command transmission, set “command reception permission OFF”.
⿎
Setting request data / response data for readout
Start
code
MKM
Sub command
[Command reception permission]
1-byte
(Check sum)
End code
Sub command is “S” for the setting request data and “A” for the response data for readout.
⿎
Readout request data
Start
code
MKM
R
(Check sum)
End code
⿎
Data description
Name
Data length
[byte]
Data contents
Remarks
Command
reception
permission
1
“0”: Command reception
permission ON
“1”: Command reception
permission OFF
Setting “command reception permission ON” turns
OFF the marking trigger ready to start receiving
commands.
Setting “command reception permission OFF” ends
the command reception to resume the marking trigger
ready ON status.
Total data
length
1
The data length is fixed.
ンㄆㄇㄆㄓㄆㄏㄆ
• Refer to “2-4 Command Reception Condition” (P.42) for details on the command reception permission.
• Send MKM command with the shutter opened state.
• When the command reception status is readout during the shutter closed, the response data indicates the status as
“command reception permission ON”.
• MKM command is not acceptable during the guide laser emission or laser radiation for measurement.
• It is possible to recover from the warning status by sending “command reception permission ON” of the MKM command.
⿎
Example of command settings
Condition:
Command reception permission = 0
• Setting
Transmission data
[STX]
MKM
S
0
[CR]
• Readout
Transmission data
[STX]
MKM
R
[CR]
Response data
[STX]
MKM
A
0
[CR]
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...