73
⿎
Timing chart for SIN command transmission
Ex. When “Characters specified by SIN command” is set to string No. 0 and 1
T2
T1
OFF (Close)
ON (Open)
ON
ON
ON
OFF
OFF
OFF
ON
OFF
ON
OFF
SINS00a
SINS01b
SINS00c
SINS01d
ACK
ACK
ACK
ACK
PROCESSING OUT (Y10)
READY OUT (Y5)
TRIGGER IN (X5)
LASER STANDBY OUT (Y6)
SHUTTER OPEN 1,2 OUT (Y8, Y9) *1
SHUTTER OPEN OUT (No.39) *2
DATA WAIT OUT (No.38) *2
SIN command
Response data
*1 : LP-GS series only
*2 : LP-RF/LP-RC/LP-RV series only
Item
Time
Remarks
T1
0 ms or more
Before sending SIN command, confirm that the shutter is opened.
For LP-RC/LP-RF/LP-RV series, you can use either SHUTTER OPEN OUT signal or
DATA WAIT OUT (No.38) to know the timing of SIN command input.
T2
0 ms or more
After confirming PROCESSING OUT (Y10) is turned ON, the next SIN command data
can be sent.
For LP-RC/LP-RF/LP-RV series, you can use either PROCESSING OUT signal or DATA
WAIT OUT (No.38) to know the timing of SIN command input.
ンㄆㄇㄆㄓㄆㄏㄆ
• SIN command can be accepted only when the shutter is open. The shutter status can be confirmed by using SHUTTER
OPEN OUT signal of I/O.
• When “command reception permission ON” is set by MKM command, SIN command can not be accepted.
• When SIN command will be sent right after file change (FNO/FNN command) or command reception permission OFF
(MKM command) setting, set the wait time of 1 second or more after FNO/FNN/MKM command reception.
• For LP-RC/LP-RF/LP-RV series, you can know the timing of SIN command input by confirming DATA WAIT OUT (No.38)
signal of I/O connector is ON.
• When the file with “Characters specified by SIN command” function is selected, transmit this command by every marking
triggers. Otherwise marking trigger ready does not turn ON, and marking is not available.
• It is not possible to send SIN command twice or more to one string number for one marking trigger.
• To reset the transmitted SIN command data, either close the shutter, or set “command reception permission ON” for
MKM command.
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...