Data example
Condition:
Starting point = -5, Ending point = 10, Corners = 10, Curve = 0, Waiting time = 20,
Pre-scan time = 1, Jump = 0, System reserved value = 0.00, System reserved value = 0.00
• Setting
Transmission data
[STX]
WTC
S
-005+01001000002001.000000.000.00
or
-005+01001000002001.00000
or
-005+01001000002001.00
[CR]
• Readout
Transmission data
[STX]
WTC
R
[CR]
Response data
[STX]
WTC
A
-005+01001000002001.000000.000.00
[CR]