Example of command settings
Condition:
Counter No. = 0, Current value = 1234, Starting value = 0, End value = 9999, Step value = 1,
Count timing = 8, Reset at date change = 1
• Setting
Transmission data [STX]
CNT
S
000123400000000999900000181
[CR]
• Readout
Transmission data [STX]
CNT
R
0
[CR]
Response data
[STX]
CNT
A
000123400000000999900000181
[CR]
ンㄆㄇㄆㄓㄆㄏㄆ
• If the counter is reset at date change during on-the-fly marking operation (single trigger mode), the marking trigger ready
status turns off momentary and there is a case that the next marking could not be executed due to Warning E751.
• With LP-400/V compatible command mode, the counter numbers 4 to 15 and global counter numbers 20 to 31 cannot be
set and readout.
• With LP-400/V compatible command mode, the counter value larger than 999999 cannot be set and readout.
3-6-2 Counter reset: CTR
Resets the current value to the starting value.
⿎
Setting request data
Start
code
CTR
S
[Counter 0] [Counter 1] [Counter 2] [Counter 3]
[Global counter 16] [Global counter 17]
[Global counter 18] [Global counter 19]
8-byte
(Check
sum)
End code
⿎
Data description
Name
Data length
[byte]
Data contents
Remarks
Counter 0
1
“0”: Do not reset
“1”: Reset
Counter 1
1
Counter 2
1
Counter 3
1
Global counter 16
1
Global counter 17
1
Global counter 18
1
Global counter 19
1
Total data length
8
The data length is fixed.
ンㄆㄇㄆㄓㄆㄏㄆ
• The setting changed by this command is saved in the laser marker without overwriting to the file.
• If the counter is reset during on-the-fly marking operation, the marking trigger ready status turns off momentary and
there is a case that the next marking could not be executed due to Warning E751.
• With LP-400/V compatible command mode, the counter numbers 4 to 15 and global counter numbers 20 to 31 cannot be
reset.
⿎
Example of command settings
Condition:
To reset counter 0 and 16
• Setting
Transmission data [STX]
CTR
S
10001000
[CR]
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...