117
Name
Data length
[byte]
Data contents
Remarks
X-movement *
(8)
“-999.999”–“+999.999” [mm]
• Moves the coordinate of the step
& repeat data (the all marking
data in the object group No.
1000).
• When these settings are omitted,
“+000.000” is applied to each.
• When the step & repeat is
OFF, these values are always
“+000.000”.
Y-movement *
(8)
Counter behavior
2
“00”: Disable “Count individually”
• When the counter function
is used in the step & repeat,
specify how the counter value is
updated.
• When the counter function is not
used in the step & repeat, set
“00”.
• When “Count individually” is
disabled, the all counter values
are the same in one step &
repeat operation.
• When “Mark OFF” is set in the
step & repeat fine-adjustment
to a specified data in the step
& repeat, the “count Mark OFF”
specifies if the counter value
of the unmarked data turns out
the vacant number (ON) or not
(OFF).
• “Counter starting position”
specifies the start position of the
counting in the step & repeat.
When “Count individually” is enabled;
• With the count direction “Horizontal”
Setting
Count “Mark
OFF”
Counter start
“10”
ON
Top left
“12”
ON
Top right
“20”
OFF
Top left
“22”
OFF
Top right
• With the count direction “Vertical”
Setting
Count “Mark
OFF”
Counter start
“11”
ON
Top left
“13”
ON
Top right
“21”
OFF
Top left
“23”
OFF
Top right
Total data length
39
(23)
(1)
Fixed length.
• When X-movement and Y-movement are not omitted: 39-byte
• When X-movement and Y-movement are omitted: 23-byte
• When step & repeat is OFF: 1-byte
• Response data for readout: 39-byte or 1-byte
* These items can be omitted when the both values are 0. It is not possible to omit one side of them.
⿎
Example of command settings
Condition:
Step & repeat ON/OFF = 1,
Number of rows = 12, Number of columns = 4, Row step = 4, Column step = 8.5,
X-movement = 0, Y-movement =0, Counter behavior = 11
• Setting
Transmission data
[STX]
SRC
S
1012004004.000008.50011
or
1012004004.000008.500+000.000+000.00011
[CR]
• Readout
Transmission data
[STX]
SRC
R
1
[CR]
Response data
[STX]
SRC
A
1012004004.000008.500+000.000+000.00011
[CR]
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...