background image

 

 

 

 

www.lancerbeverage.com

 

Page 1 of 3 

Images are for illustration purposes only as product may vary. 

No 075  

–  1 November 2018

 

BEV85 Quarterly Service 

Work Instruction 

Why 

Condition and operational service of the BEV85 Oil Free Air Compressor 

Time required 

20 minutes to complete 

 

Hazard icons 

       

Tools and supplies 

 

 
 

 

 

 

 

Videos are available to support this equipment from Hoshizaki Lancer.  
Please see: 

www.lancerbeverage.com 
 

Overview: 

https://youtu.be/-pKwifqzQEY 

 

Troubleshooting: 

https://youtu.be/OobMs8csyj0 

 

Service: 

https://youtu.be/_jS9Mm8xmXQ

 

Safety 

Glasses 

Paper 
Towel 

Gloves 

Tools 

Cleaning 

alcohol 

Soapy water 

Procedure

Change Over to CO2 supply 

Switch main Beverage Control 
Panel over to back-up CO2 
supply. 
 

 

Isolate Air Compressor 

– 

Electrical 

 

Press the red button on the 
pressure switch to turn off the 
compressor.   
 
Isolate and disconnect the 
electrical lead from the wall 
socket. 
 

 

 

Isolate Air Compressor 

–  

Air Supply 

Turn the supply air tap off, ¼ 
turn. The red handle will be 90 
degrees to the hose when off. 

 

Drain air tank 

 

Drain the air tank through the 
Drain Cock on the base of the 
receiver tank.  
 
Turn Clockwise, slowly loosen 
Drain Cock to release 
compressed air.  
Monitor for excessive 
moisture draining from the 
tank. 

 

Compressed air use of Gloves 
& safety glasses is required. 

 

 

 

Replace Tank Drain Cock 

Wipe drain cock clean.   
 
Refit drain cock, turning anti-
clockwise, ensure finger tight 
fitment.  

 

Inspect and Drain Regulator 
Filter bowl. 

Check the condition of the 
condensation bowl at the base 
of the Filter Regulator. 
If dirty and/or more than 
10mm of moisture present 
remove & clean.

 

 

 

 

Reviews: