background image

BEV85 Quarterly Service 
Work Instruction

 

 

www.lancerbeverage.com

 

 

Page 2 of 3 

Images are for illustration purposes only as product may vary. 

No 075  

–  1 November 2018

 

 

Remove Regulator Filter 
Bowl 

Turn Clockwise and pull down 
to remove. 
 
Clean with warm soapy water. 
 

 

 

Remove Regulator Brass 
Filter 

Turn the Brass Cartridge 
Clockwise to loosen and 
remove. 
 
Clean with warm soapy water. 
 
Clean by placing in sanitiser 
alcohol to soak and shake. 
 
Refit by turning anti-clockwise 
once cleaned or replaced. 

 

 

Replace Regulator Filter 
Bowl 

Push up and turn anti-
clockwise to replace bowl.  

 

Access Air filters (2 of) 

Twist anti-clockwise and pull 
on the filter casing cap to 
expose the filter element 
inside. 

 

 

Inspect & Clean air filter 

Clean filter by Tapping or dust 
off from back direction. 
 
Inspect behind filter, if housing 
is dirty or oily wipe clean. 
 

 

Replace filters every quarter 
where installed outdoors, in 
damp, dusty or oily 
environments. 

 

 

 

Replace air filter & Cap 

Replace air filter. 
 
Locate filter cap onto the 
housing and twist clockwise to 
replace and lock into place. 

 

Inspect the Non-Return 
Valve Seal 

 

 
 
 
 
 
 
 
With the use of a Spanner 
turn the nut anti-clockwise to 
loosen.  
 
 
 
 
Remove and expose the 
spring & seal. 
 

 

Note orientation of parts as 
removing them. 
 
 
Inspect & wipe Clean face of 
seal & NRV body. 
 
 
 
 
Replace Seal & Spring, and 
nut.  Tighten using only 
fingers, in a Clockwise 
direction.  
 
 

 

 

 

 

 

 
 

 

 

 

Re-connect and energise 
the electrical supply to the 
air compressor 

 

Plug electrical lead into socket 
outlet and lift red button on 
pressure switch to turn on the 
air compressor. 

 