151
ERROR
CODE
Description
Measures *1
E205 - E207
• Abnormality occurs on the internal shutter.
• Signal cable is not connected properly.
Check the connection of the cable and various
signal lines, and then restart the laser marker.
E220
Laser head housing is open.
Contact our sales office or representatives.
E225 *4
Fiber unit is detached.
Install the fiber unit properly by following the
procedures described in the Setup/Maintenance
Guide.
E250 - E252
E260 - E261
E264 - E265
• An error has occurred to the laser oscillator.
• A power supply voltage error was detected in
the laser oscillator.
• Incorrect connection of signal cable or unit
power cable.
• Check and correct the power status.
• Check if the AC power line is effected by noise.
• Check the connection of the cable and various
signal lines, and then restart the laser marker.
• For LP-RC series:
Check if the ambient temperature of the
laser marker is not exceeding the range of its
specification.
E262 *4
Temperature error in laser oscillator.
• Check if the ambient temperature of the
laser marker is not exceeding the range of its
specification.
• Make sure air-cooling fan operates.
• Remove the dust and contamination in the
air intake and exhaust port, and clean the air-
cooling part such as fan and filter.
• When not recovered, contact our sales office
or representatives.
E263 *4
Detected unintended-irradiation.
Contact our sales office or representatives.
E270 - E275
E277
E280 - E285
E287
• An error has occurred to the galvano scanner
of the head.
• Incorrect connection of signal cable or unit
power cable.
• Check and correct the power status.
• Check if the AC power line is effected by noise.
• Check the connection of the cable and various
signal lines, and then restart the laser marker.
Marking data are too detailed for the scan speed
configured.
Decrease the scan speed.
E290 - E291
*2
An error has occurred to the Z-axis adjustment
module.
Check the connection of the cable and various
signal lines, and then restart the laser marker.
E400
INTERLOCK 1 of the I/O terminal block was
released.
• Connect INTERLOCK terminals on the I/O
terminal block.
• Check the status of the safety equipment
connected to INTERLOCK terminal.
• Confirm operation logic of connection device.
• For LP-RC/LP-RF/LP-RV series:
If the error cannot be solved even with the
proper connection of INTERLOCK terminals,
replace the contactor for INTERLOCK by
following the procedures described in the
Setup/Maintenance Guide.
E401
INTERLOCK 2 of the I/O terminal block was
released.
ME-LP-GS-SR-COMP-3
Summary of Contents for LP-GS Series
Page 11: ...1 Preparation of Command Control ME LP GS SR COMP 3...
Page 26: ...2 Communication Control Basics ME LP GS SR COMP 3...
Page 50: ...3 Data Format for Each Command ME LP GS SR COMP 3...
Page 136: ...136 MEMO ME LP GS SR COMP 3...
Page 137: ...Troubleshooting ME LP GS SR COMP 3...
Page 163: ...Character Code Table ME LP GS SR COMP 3...
Page 176: ...Index ME LP GS SR COMP 3...
Page 178: ...178 W Warning 154 ME LP GS SR COMP 3...
Page 179: ......
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019...